Electrical connection
Electrical connection of the appliance
should be made by a qualified electri-
cian and in accordance with local and
national standards.
Note to installer:
Please leave these instructions with
the consumer.
Power supply:
Please check dataplate for
240 VAC; 60 Hz or
208 VAC; 60 Hz
Caution:
Disconnect the power supply be-
fore servicing. To reduce the risk of
electric shock, make sure that the
appliance is properly grounded
after installation.
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
For CDN only
The appliances are provided with 3 ter-
minal leads: 1 black wire, 1 red wire
and 1 green wire which have to be con-
nected to a separate overcurrent pro-
tection device (Miele fuse box).
All hot wires (black and red) have to be
fused individually before connecting
them to the main power supply leads.
Use 15 A / 250 V fuses for ap-
pliances rated 240 VAC.
Connect black terminal wire to L1
(black) and red terminal wire to L 2
(red). The green terminal wire (ground)
has to be connected directly to the
equivalent colored power supply leads.
All connections must be done in a
proper way.
SEE ALSO WIRING DIAGRAM PRO-
VIDED WITH THE APPLIANCE.
For USA only
The appliance is provided with 3 termi-
nal leads, 1 black wire (L 1), 1 red wire
(L 2) and 1 green wire (GND) which
have to be connected to a dedicated
junction box. Connect black wire to L1,
red wire to L2 and green wire to GND.
All connections must be done
according to code.
SEE THE CIRCUIT DIAGRAM PRO-
VIDED WITH THE APPLIANCE.
Electrical connection
18