Electrical connection
The refrigeration appliance must only be
connected to a grounded outlet using
the power cord supplied.
The outlet must be easily accessible af-
ter the refrigeration appliance has been
installed. If the outlet is not easily ac-
cessible, ensure that a suitable means
of disconnection is provided on the in-
stallation side for each pole.
Risk of fire from overheating.
Connecting the refrigeration appli-
ance to a power bar or to an exten-
sion cord can overload the cord.
For safety reasons, do not use a
power bar or an extension cord.
The electrical installation must comply
with VDE 0100.
For safety reasons, we recommend us-
ing a type
residual current device
(RCD) in the assigned electrical installa-
tion for connecting the refrigeration ap-
pliance.
If the power cord is damaged, it must
only be replaced with a specific cord of
the same type (available from Miele
Customer Service). For safety reasons,
such replacement may only be carried
out by a qualified technician or Miele
Customer Service.
These operating instructions and the
data plate indicate the nominal power
consumption and the appropriate fuse
rating. Compare this information with
the data of the on-site electrical con-
nection.
If in any doubt, consult a qualified elec-
trician.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not syn-
chronized with the grid power supply
(e.g., island networks, back-up sys-
tems) is possible. A prerequisite for op-
eration is that the power supply system
complies with the specifications of
EN 50160 or an equivalent standard.
The function and operation of the pro-
tective measures provided in the do-
mestic electrical installation and in this
Miele product must also be maintained
in isolated operation or in operation that
is not synchronized with the grid power
supply, or these measures must be re-
placed by equivalent measures in the
installation. As described, for example,
in the current version of VDE-AR-E
2510-2.
Connecting the appliance
Insert the electrical plug into the back
of the refrigeration appliance.
Make sure that the electrical plug has
clicked into position correctly.
Insert the electrical plug of the refrig-
eration appliance into the socket.
The refrigeration appliance is now con-
nected to the electricity supply.