Oven
The oven is supplied for connection
with an approx. 1.7 m long connection
cable and must be connected to the
mains according to the wiring diagram.
Maximum rated load: see data plate.
The wires in the mains connection
cable are coloured in accordance with
the following code:
Green/yellow = earth
Blue = neutral
Brown = live
WARNING: THIS APPLIANCE MUST BE
EARTHED
Three phase 3 N AC 230 V
Wiring diagram – country variant
Single phase AC 230 V
This device is intended for connection
to a power supply system where the
maximum value of external phase
neutral loop impedance Z
max
of
0.35 Ohms at the point of distributor
supply connection is not exceeded.
If in doubt, please ask your electrical
distributor for actual Z
max
value. The
user has to ensure that this device is
connected only to a power supply
system which fulfils the requirement
above.
Wiring diagram – country variant
Electrical connection