All electrical work should be carried out by a suitably
qualified and competent person, in strict accordance with
current local and national safety regulations (BS 7671 in
the UK).
Installation, repairs and other work by unqualified persons
could be dangerous. The manufacturer cannot be held
liable for unauthorised work.
Ensure power is not supplied to the appliance until after
installation work has been carried out.
The appliance must only be operated when built-in. This is
to ensure that all electrical parts are shielded. Live parts
must not be exposed.
Do not connect the appliance to the mains electricity
supply via an extension lead. These do not guarantee the
required safety of the appliance.
Please ensure that the connection data quoted on the data
plate match the household mains supply.
This appliance is supplied with a cable and moulded plug for
connection to a single phase 230-240 V 50 Hz supply via a
suitable switched socket which should be easily accessible
after installation.
It can, if necessary, be connected to a suitable isolator or a
double pole fused spur connection unit which complies with
national and local safety regulations by a suitably qualified
electrician.
If the switch is not accessible after installation (depending on
country) an additional means of disconnection must be
provided for all poles.
For extra safety it is advisable to protect the appliance with a
suitable residual current device.
When switched off there must be an all-pole contact gap of
3 mm in the isolator switch (including switch, fuses and
relays).
Electrical connection
46