Installation
*INSTALLATION*
44
Adjusting the vapour shield
When retracted, the deflector plate is
held in place by magnets.
The retaining force of the magnets can
be adjusted. The magnets should be
adjusted such that the deflector plate is
held in place securely on the left and
right hand side and can be lowered
slightly. An angled key is supplied for
adjusting the magnets.
Adjust both sides equally. Turn
in
stages
by a half turn each time and
check the adjustment by lowering
and raising the deflector plate.
- Turning the adjusting screws
clockwise increases the magnetic
retaining force.
- Turning the adjusting screws anti-
clockwise reduces the magnetic
retaining force.
Connection for air extraction
Before installation, it is important
to read the information given on the
following pages as well as the
“Appliance dimensions” and the
“Warning and Safety instructions” at
the beginning of this booklet. This is
particularly crucial when using the
rangehood at the same time as a
heating appliance that relies on
oxygen from the same room, which
could result in the build-up of toxic
fumes.
The rangehood should be installed
according to local and national
building regulations. Seek approval
from the building inspector where
necessary.
Only use smooth pipes or flexible
ducting made from approved non-
flammable materials for exhaust
ducting.
To achieve the most efficient air
extraction with the lowest noise levels,
please note the following:
- The diameter of the exhaust ducting
must not be smaller than the cross-
section of the exhaust connection
(see "Appliance dimensions"). This is
particularly applicable when using flat
ducting.
- The exhaust ducting must be as
short and straight as possible.
- Only use wide radius bends.
- The exhaust ducting must not be
kinked or compressed.
- All connections must be strong and
airtight.
Содержание DAS 8630
Страница 14: ...Guide to the rangehood 14 ...
Страница 49: ......
Страница 50: ......
Страница 52: ...M Nr 12 039 300 00 en AU NZ DAS 8630 DAS 8930 ...