background image

Warning and Safety instructions

3

This appliance complies with all relevant local and national safety
requirements. Inappropriate use can, however, lead to personal
injury and damage to property.

To avoid the risk of accidents and damage to the appliance, please
read these instructions carefully before using it for the first time.
They contain important notes on the safety, installation, use and
maintenance of the appliance. Miele cannot be held liable for non-
compliance with these instructions.

Keep these instructions in a safe place and ensure that all users
are familiar with the contents. Pass them on to any future owner of
the appliance.

Correct application

 

This rangehood is designed for domestic use and for use in similar

environments by guests in hotel or motel rooms, bed & breakfasts
and other typical living quarters. This does not include common/
shared facilities or commercial facilities within hotels, motels or bed
& breakfasts.

 

The appliance is not suitable for outdoor use.

 

It must only be used to extract vapours and remove odours from

cooking.
Any other usage is at the owner's risk. Miele cannot be held liable for
damage resulting from incorrect or improper use or operation.

 

Where a recirculation rangehood is fitted above a gas cooktop,

please ensure that there is an adequate supply of fresh air into the
room in which it is installed. Please seek the advice of a qualified gas
fitter if necessary.

Содержание DAR 1120

Страница 1: ... installation instructions Rangehood To prevent the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time en AU NZ M Nr 10 582 860 ...

Страница 2: ... active charcoal filters 22 Disposing of the charcoal filters 22 Installation 23 Before installation 23 Protective foil 23 Installation instructions 23 Assembly parts 24 Appliance dimensions 26 Exhaust connection DRRV for rear venting 28 DRDC fascia panels DRUU recirculation conversion kit 29 Safety distance S 30 Installation recommendations 31 Connection for air extraction 32 Electrical connectio...

Страница 3: ...to any future owner of the appliance Correct application This rangehood is designed for domestic use and for use in similar environments by guests in hotel or motel rooms bed breakfasts and other typical living quarters This does not include common shared facilities or commercial facilities within hotels motels or bed breakfasts The appliance is not suitable for outdoor use It must only be used to...

Страница 4: ...ldren may only use the appliance when its operation has been clearly explained to them and they are able to use it safely recognising the dangers of misuse Cleaning work may only be carried out by older children under the supervision of an adult Children should be supervised near the appliance Ensure that they do not play with the appliance The cooktop lighting is very intense Ensure in particular...

Страница 5: ...is present and tested regularly and where there is any doubt the household wiring system should be inspected by a qualified electrician Reliable and safe operation of this rangehood can only be assured if it has been connected to the mains electricity supply Before connecting the appliance to the mains supply ensure that the connection data on the data plate voltage and frequency matches the mains...

Страница 6: ... not repaired by a Miele approved service technician Faulty components must only be replaced by genuine Miele spare parts The manufacturer can only guarantee the safety of the appliance when Miele replacement parts are used If the mains connection cable is damaged it must only be replaced by a Miele authorised service technician or suitably qualified electrician in order to avoid a hazard During i...

Страница 7: ...water heaters gas cooktops or ovens which draw air in from the room and duct exhaust gases out through a chimney or extraction ducting When used in extraction mode with or without an external motor fitted or in recirculation mode with a recirculation box installed outside the room the appliance draws air in from the room in which it is installed and from neighbouring rooms If there is insufficient...

Страница 8: ... that the rangehood can only be switched on when the heating appliance is switched off or vice versa A ventilation brick alone is not generally sufficient to ensure safe ventilation The overall ventilation condition of the dwelling must be taken into account If in any doubt the advice of a competent builder or for gas a qualified gas fitter registered with an official gas safety body in accordance...

Страница 9: ...s covered by a pan Switch the cooking zone off when a pan is removed even for a short time Select a pan which is suitable for the size of the burner Regulate the flame so that it does not burn up the sides of the pan Avoid overheating the pan e g when cooking with a wok Always switch the rangehood on when a cooking zone is in use otherwise condensation may collect in the rangehood which could caus...

Страница 10: ...s to whether a rangehood may be operated above the cooktop Safety regulations prohibit the fitting of a rangehood over solid fuel stoves Insufficient distance between the cooktop and the rangehood can result in damage to the rangehood The minimum safety distances between the top of the cooktop and the bottom of the rangehood given in the Installation section must be maintained unless the cooktop m...

Страница 11: ...ng and care There is a risk of fire if cleaning is not carried out as described in these operating instructions In areas which may be subject to infestation by cockroaches or other vermin pay particular attention to keeping the machine and its surroundings in a clean condition at all times Any damage which may be caused by cockroaches or other vermin will not be covered by the machine warranty Do ...

Страница 12: ...lectrical and electronic appliances often contain valuable materials They also contain specific materials compounds and components which were essential for their correct function and safety These could be hazardous to human health and to the environment if disposed of with your domestic waste or if handled incorrectly Please do not therefore dispose of your old appliance with your household waste ...

Страница 13: ...ange of room and outside air taking place The flap is closed when the rangehood is switched off When the rangehood is switched on the non return flap opens for the cooking vapours to be blown directly outside If the on site ventilation system does not have a non return flap the non return flap supplied must be fitted Recirculation mode with conversion kit DRUU The air is drawn in and cleaned first...

Страница 14: ...Guide to the appliance 14 ...

Страница 15: ... mode with conversion kit DRUU c Canopy d Charcoal filter Optional accessory for recirculation mode The charcoal filters are mounted to the rear panel of the baffle filter e Baffle filter f Cooktop lighting g Controls h Drip tray i Rotary control for cooktop illumination j Rotary control for the fan dai3822 Miele fan motor DRIB XXL ...

Страница 16: ...ch the rangehood on when a cooking zone is in use The rangehood is fitted with a temperature sensor If a fan power level that is too low is selected the rangehood automatically switches temporarily to the booster setting This occurs even if the rangehood is switched off Switching the fan off It is advisable to run the fan for a few minutes after cooking has finished to neutralise any lingering vap...

Страница 17: ... power level and therefore benefit from reduced energy consumption Check the power level selected on the rangehood A lower power level is generally sufficient for the majority of cooking Only use the Booster setting when necessary When a large volume of cooking vapours are being produced switch to a high power level in good time This is more efficient than operating the rangehood for longer to try...

Страница 18: ...brasive sponges as well as pot scourers or sponges which have been used previously with abrasive cleaning agents These will damage the surface material Important for appliances with stainless steel surfaces Stainless steel surfaces can be cleaned with a proprietary non abrasive cleaning agent designed specifically for use on stainless steel e g Original Miele ceramic and stainless steel cooktop cl...

Страница 19: ...od of time and makes cleaning more difficult It is therefore recommended to clean the baffle filters every 3 4 weeks Removing the baffle filters When handling a grease filter be careful not to drop it This can result in damage to the filter and the cooktop below Make sure you hold the filter securely at all times when handling it Push the baffle filter upwards swing it towards you and remove the f...

Страница 20: ...or inclined in the lower basket Ensure the spray arm is not obstructed Use a standard household dishwasher detergent Select a dishwasher programme with a wash temperature between 50 C and 65 C After cleaning After cleaning leave the baffle filters on an absorbent surface to dry When removing the baffle filters for cleaning also clean off any residues of oil or fat from the now accessible housing t...

Страница 21: ...Cleaning and care 21 Fitting the baffle filters Push the baffle filter upwards and insert it at the bottom ...

Страница 22: ...e number can be found in Technical Data Fitting and replacing the charcoal filters Before fitting or replacing the charcoal filters the baffle filters must first be taken out see previous section for instructions on how to do this Unwrap the charcoal filters Open the charcoal filter frames Insert the charcoal filters and close the frames again Refit the baffle filters When to change the NoSmell ac...

Страница 23: ...ety instructions at the beginning of this booklet Protective foil The housing components have protective foil around them to prevent them from transport damage Please remove this foil before fitting the housing components It can be peeled off easily Installation instructions See enclosed installation sheet for instructions on how to install this appliance ...

Страница 24: ...Installation 24 Assembly parts ...

Страница 25: ...nly For other types of wall construction alternative fixings will be required Make sure the wall is able to take the weight of the rangehood 2 self locking screws M6 x 16 mm for attaching the DAR 12xx to the mounting rail 4 screws M4 x 11 mm with base and 2 clamps for securing the DRDC and DRUU fascia panels DAR 12xx only 8 screws M4 x 8 mm for fastening the cover caps and the clamps DAR 12xx only...

Страница 26: ...Installation 26 Appliance dimensions Extractor units DAR 1120 DAR 1130 DAR 1150 a Fixing points there must be a sub construction capable of bearing the load in the area of the fixing points ...

Страница 27: ...Wall rangehoods DAR 1220 DAR 1230 DAR 1250 a Fixing points the wall to which the rangehood is fixed must be capable of supporting the weight of the appliance b The exhaust connection is not used for recirculation mode ...

Страница 28: ...Installation 28 Exhaust connection DRRV for rear venting optional accessory a On site extraction ducting ...

Страница 29: ...Installation 29 DRDC fascia panels DRUU recirculation conversion kit The DRDC fascia components can be additionally installed above the DRUU conversion kit ...

Страница 30: ...gas cooktop with maximum 45 4 MJ h total output with no burner having a greater output than 16 2 MJ h 650 mm Multi burner gas cooktop with total output greater than 45 4 MJ h but with a maximum of 77 8 MJ h with no burner having a greater output than 17 3 MJ h 760 mm Multi burner gas cooktop with total output greater than 77 8 MJ h with a single burner having a greater output than 17 3 MJ h Not po...

Страница 31: ...h the rangehood controls with ease If positioned too high extraction will be inefficient To achieve optimum vapour extraction the rangehood must be positioned centrally over the cooktop not to the side The cooktop should be no wider than the rangehood and if possible it should be narrower especially for safety distances greater than 750 mm The installation area must be easily accessible The rangeh...

Страница 32: ...tion of the exhaust ducting must not be smaller than the cross section of the exhaust connection see Appliance dimensions The exhaust ducting should be as short and straight as possible Only use wide radius bends The exhaust ducting must not be kinked or compressed When selecting the exhaust ducting ensure that it is rigid enough to retain its shape during operation Ensure that all connections are...

Страница 33: ...or extra safety it is advisable to install a residual current device RCD with a trip current of 30 mA Connection of this appliance must be made via a suitable isolator switch which provides disconnection on all poles and which complies with national and local safety regulations The isolator switch should be easily accessible after the appliance has been built in If the mains socket is not accessib...

Страница 34: ...al number of your appliance These can be found on the data plate Position of the data plate The data plate is visible after removing the baffle filters Warranty AU NZ The manufacturer s warranty for this appliance is 2 years For further information please refer to your warranty booklet Warranty Other countries For information on the appliance warranty specific to your country please contact Miele ...

Страница 35: ...ength 1 5 m Weights DAR 1120 without fan 16 kg DAR 1130 without fan 19 kg DAR 1150 without fan 25 kg DAR 1220 without fan 27 kg DAR 1230 without fan 33 kg DAR 1250 without fan 48 kg Fan motor DRIB XXL 11 3 kg Special accessory for recirculation mode Conversion kit from extraction mode to recirculation mode for DAR 1220 Conversion kit DRUU 30 and charcoal filter DKF 23 1 contains 2 charcoal filters...

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ... Level 12 Menara Sapura Kencana Petroleum Solaris Dutamas No 1 Jalan Dutamas 1 50480 Kuala Lumpur Malaysia Phone 603 6209 0288 Fax 603 6205 3768 Miele Australia Pty Ltd ACN 005 635 398 ABN 96 005 635 398 Miele Experience Centre and Head Office Melbourne 1 Gilbert Park Drive Knoxfield VIC 3180 www miele com au Miele New Zealand Limited IRD 98 463 631 Head Office Level 2 10 College Hill Freemans Bay...

Страница 40: ...M Nr 10 582 860 00 en AU NZ DAR 1120 DAR 1130 DAR 1150 DAR 1220 DAR 1230 DAR 1250 DRIB XXL ...

Отзывы: