background image

Operating and Installation Instructions
Ventilation System

To prevent accidents and damage to the appliance, you 

must

 read

these instructions before installing the appliance and using it for the first
time.

en-US

M.-Nr. 10 296 130

Содержание DA 7000 D

Страница 1: ...d Installation Instructions Ventilation System To prevent accidents and damage to the appliance you must read these instructions before installing the appliance and using it for the first time en US M Nr 10 296 130 ...

Страница 2: ...indicator 20 Sensor button signal tone 21 Cleaning and care 22 Stainless steel housing 22 Special instructions for glass surfaces 22 Grease filters 23 Resetting the filter saturation indicator for the grease filter 24 OdorFree Charcoal Filter 25 Resetting the filter saturation indicator for the OdorFree Charcoal Filter 26 Disposing of the OdorFree Charcoal Filter 26 Changing a halogen lamp 27 Serv...

Страница 3: ... Exhaust Hazardous Or Explosive Materials And Vapors This appliance is intended for residential use only Use only as described in these operating instructions This ventilation hood is designed for domestic use and for use in similar residential environments This ventilation hood is not intended for outdoor use It must only be used to extract and clean vapors produced during cooking Any other use o...

Страница 4: ... appliance switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally If the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation repair and maintenance work should be performed by a Miele authorized service technician in accordance with nation...

Страница 5: ...cy on the data plate correspond to the building s power supply before connecting the appliance When in doubt consult a qualified electrician Do not use a power bar or extension cord to connect the ventilation hood to electricity These are a fire hazard and do not guarantee the required level of appliance safety To ensure safe operation only use the ventilation hood after it has been properly insta...

Страница 6: ...ent has been unplugged from the socket pull the plug not the cord Proper use WARNING TO REDUCE THE RISK OF A COOKTOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers may ignite Heat oils slowly on low or medium settings b Always turn the hood on when cooking at a high heat c Clean the ventilation hood frequently Grease should not be ...

Страница 7: ...it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA The ventilation hood may become damaged if exposed to excessive heat from a gas cooktop When using the ventilation hood over a gas cooktop ensure that any burners in use are always covered by co...

Страница 8: ...the proper functioning of the ventilation hood To ensure that cooking vapors are properly cleaned never use the ventilation hood without the grease filters in place There is a risk of fire if cleaning is not completed according to the instructions in this manual Please note that the heat rising from the stovetop during cooking can cause the ventilation hood to become very hot Do not touch the hous...

Страница 9: ...ll or ceiling do not damage electrical wiring and other hidden utilities d Ducted hoods must always be vented to the outdoors e Do not use this hood with any solid state speed control device To determine whether a ventilation hood may be operated above your cooking appliance please refer to the information provided by the appliance s manufacturer Safety regulations prohibit the installation of a v...

Страница 10: ...ubes made of non flammable material These can be obtained from your Miele dealer or from Miele Technical Service Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel burning installations If exhaust air is to be extracted into a chimney or vent flue no longer used for other purposes be sure ...

Страница 11: ...use a steam cleaner to clean the ventilation hood The steam can reach the electrical components and cause a short circuit Accessories Use only genuine original Miele parts If parts or accessories from other manufacturers are used the warranty will become void ...

Страница 12: ... reach of children Danger of suffocation Disposal of your old appliance Do not dispose of this appliance with your household waste Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Before discarding an old appliance ensure that it presents no danger to children while being stored for disposal U...

Страница 13: ...od depending on the model Recirculation mode This ventilation hood operates solely in recirculation mode The air drawn in is cleaned by the grease filters and then by 2 OdorFree charcoal filters The cleaned air is then recirculated back into the kitchen through vents at the top of the hood ...

Страница 14: ...Guide to the appliance 14 ...

Страница 15: ... You will hear a brief beep as confirmation f Overhead lighting g OdorFree charcoal filters x 2 h Recirculation vents i Sensor button for the overhead lighting j Sensor button for turning the fan on and off k Sensor buttons for fan power selection l Sensor button for delayed shut down function m Filter saturation indicator for the grease filters n Filter saturation indicator for the OdorFree charc...

Страница 16: ...ction of the intensive setting The intensive level can be programmed to switch back to level 3 automatically after 10 minutes Turn off the fan and the lighting Press the delayed shut down button for approx 10 seconds until 1 lights up in the fan power display Next tap the following buttons in succession The lighting button Followed by the 1 button and then The lighting button again If automatic sw...

Страница 17: ...unction it is possible to have the fan automatically shut off after a predetermined period of time After you have finished cooking tap the delayed shut down button Once fan switches off after 5 minutes 5 lights up Twice fan switches off after 15 minutes 15 lights up If you press the delayed shut down button again the fan remains turned on 5 15 goes out Turning off the fan Press the On Off button t...

Страница 18: ...r symbol or OdorFree Charcoal Filter symbol Additional information on cleaning and changing the filters and resetting the filter saturation counters can be found under Cleaning and care Adjusting the filter saturation indicator for the grease filter You can set the filter saturation indicator to suit your cooking habits The factory default setting is a cleaning interval of 30 hours Select a shorte...

Страница 19: ... mode The operating hours counter for the charcoal filter requires one time activation and must be set to match your cooking habits Press the On Off button to turn the fan off Tap the delayed shut down button and the charcoal filter button at the same time The charcoal filter symbol and one of the fan setting indicators will flash The indicators 1 to 4 show the current time setting Indicator 1 120...

Страница 20: ...and hold the grease filter button or the charcoal filter button One or more of the power level indicators will flash The number of flashing indicators shows the elapsed operating hours as a percentage Indicator 1 25 Indicators 1 and 2 50 Indicators 1 to 3 75 Indicators 1 to 4 100 The elapsed operating hours remain stored in the memory when the hood is turned off or if power to the appliance is los...

Страница 21: ...utton to turn the fan off Tap the 4 and the grease filter buttons at the same time for approx 5 seconds until a short signal tone is heard The signal tone is now turned off for all functions To reactivate the signal tone follow the same steps If the hood is disconnected from the power supply or after a power interruption the beep is automatically reactivated regardless of the previous settings ...

Страница 22: ...surfaces with a soft cloth Avoid the following Cleaners containing soda acid or chloride or cleaners containing solvents Abrasive cleaners such as scouring powder scouring liquid abrasive sponges such as pot scourers or used sponges that still contain residues from abrasive cleaners Special instructions for RAL color finish housing Observe the general cleaning instructions contained in this chapte...

Страница 23: ...saturation counter to match your cooking habits see Operation Removing the grease filters When handling a grease filter be careful not to drop it This can result in damage to the filter and to the cooktop Make sure you hold the filter securely at all times when handling it To remove a grease filter release the locking clip Then open the filter to a 45 angle unhook it and remove it from the hood Cl...

Страница 24: ... When removing the filters for cleaning also clean off any accessible oil or fat buildup from the housing Doing so will prevent a fire hazard Reinstall the grease filters When inserting the filters make sure that the locking clip is facing down If the filters have been installed incorrectly you can insert a small screwdriver into the slit to disengage the locking clip Resetting the filter saturati...

Страница 25: ... available from your Miele dealer or from Miele See Technical data for the type and reference number Installing replacing the OdorFree Charcoal Filter Before fitting or replacing a charcoal filter the grease filters must first be taken out see previous section for instructions on how to do this Remove the charcoal filter from its packaging Open the holders for the charcoal filters Insert the charc...

Страница 26: ...e see the Operation chapter Resetting the filter saturation indicator for the OdorFree Charcoal Filter If the filter saturation indicator is activated it must be reset each time the filter is changed Press the OdorFree Charcoal Filter button for approx 3 seconds with the hood turned on until only the indicator light for level 1 is flashing The grease filter symbol will go out If you replace the Od...

Страница 27: ...om the electrical supply before replacing the lamps see IMPORTANT SAFETY INSTRUCTIONS To access the halogen lamp press the lamp cover gently upwards The cover will open and can then be lowered Pull the halogen lamp out of its socket Replace it with a new halogen lamp 12 V 20 W G4 Wear a glove or use a soft cloth to hold it and push it into the socket carefully Please follow the lamp manufacturer s...

Страница 28: ...Technical Service Department is listed at the back of these instructions When contacting Miele please state the model and serial number of your ventilation hood These can be found on the data plate Location of the data plate The data plate is visible once you have removed the grease filters Warranty For further information please refer to your warranty booklet ...

Страница 29: ...e required Make sure the ceiling is able to take the weight of the appliance Drilling template One of the cardboard inserts serves as the drilling template 4 mounting sets For hanging the ventilation hood consisting of 4 cables 4 ceiling fasteners and 4 caps The cables must not be used for securing other components such as a shelf 3 cable clamps For securing the power cord to one of the mounting c...

Страница 30: ...Installation 30 Appliance dimensions ...

Страница 31: ...on Miele range Electric Cooktops 24 610 mm Electric Barbeques and Fryers 26 660 mm Multiburner Gas Cooktops 43 000 BTU hr 12 6 kW no burner 15 000 BTU hr 4 5 kW 26 660 mm 30 760 mm Multiburner Gas Cooktops 73 800 BTU hr 21 6 kW no burner 16 500 BTU hr 4 8 kW 30 760 mm Multiburner Gas Cooktops 73 800 BTU hr 21 6 kW or one of the burners 16 500 BTU hr 4 8 kW Not possible Single Burner Gas Cooktops 2...

Страница 32: ...ure that the hood covers the cooktop The hood should be positioned centrally over the cooktop not to the side or rear The cooktop should be no wider than the hood Preferably it should be narrower The mounting area must be easily accessible The ventilation hood should be easy to reach and disassemble in case a service call is necessary This should be taken into consideration when planning the posit...

Страница 33: ...nd acceptable for use with this model hood If there is any question concerning the electrical connection of this appliance to your power supply please consult a licensed electrician or call Miele s Technical Service Department WARNING THIS APPLIANCE MUST BE GROUNDED Grounding Instructions WARNING Improper grounding can result in a risk of electric shock This appliance must be grounded In the event...

Страница 34: ...g 3 x 20 W Total connected load 160 W Voltage frequency 120 V AC 60 Hz Fuse rating 10 A Power cord length 5 9 ft 1 8 m Weight 70 5 lbs 32 kg Optional accessories for recirculation mode OdorFree charcoal filter set DKF 26 1 Contains two charcoal filters ...

Страница 35: ...l Service Canada Importer Miele Limited Headquarters and Miele Centre 800 843 7231 609 419 4298 Technical Service Support Nationwide Phone Fax TechnicalService mieleusa com 161 Four Valley Drive Vaughan ON L4K 4V8 www miele ca 800 999 1360 888 586 8056 Customer Care Centre Phone customercare miele ca 800 565 6435 905 532 2272 Germany Manufacturer Miele Cie KG Carl Miele Straße 29 33332 Gütersloh ...

Страница 36: ...M Nr 10 296 130 01 en US DA 7000 D ...