Operating and Installation
Instructions
Ventilation Hood

To prevent accidents and damage to the appliance, you 

must

 read

these instructions before installing the appliance and using it for the
first time.

en-US

M.-Nr. 11 743 460

Содержание DA 6526 W

Страница 1: ...nd Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance you must read these instructions before installing the appliance and using it for the first time en US M Nr 11 743 460 ...

Страница 2: ...t 22 Safety shut off 23 Operation Automatic and Manual modes 24 Filter saturation indicator 24 Adjusting the grease filter filter saturation indicator 24 Activating changing the charcoal filter saturation indicator 25 Checking the filter saturation indicator 25 Cleaning and care 26 Stainless steel housing 26 Important information for appliances with lacquered casing 26 Panels and grease filters fo...

Страница 3: ...Activating Con ctivity 2 0 41 Installation of the Con ctivity 2 0 stick 41 Activating the Con ctivity 2 0 function 41 Activating the ventilation hood 41 Activating the cooktop 42 Activation failed 42 Deactivating Con ctivity 2 0 42 Customer Service 43 Contact in the event of a fault 43 Location of the data plate 43 MieleCare 43 Technical data 44 Optional accessories for recirculation mode 44 ...

Страница 4: ... CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors This appliance is intended for residential use only Use only as described in these operating instructions This ventilation hood is not intended for outdoor use It must only be used to extract and clean vapors produced during cooking Any other use occurs at the owner s own risk This appliance...

Страница 5: ... the service panel and lock the service disconnecting means to prevent power from being switched on accidentally If the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Unauthorized installation maintenance and repairs can cause considerable danger for the user Installation maintenance and repairs must only be carried out by...

Страница 6: ...it has been properly installed This ventilation hood may not be used in non stationary locations e g on a ship Adequate ventilation must be provided when the hood is operated simultaneously with devices that burn gas or other fuels Only open the housing as described in the enclosed Installation diagram and in the Cleaning and care section of this manual Under no circumstances should any other part...

Страница 7: ...KTOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers may ignite Heat oils slowly on low or medium settings b Always turn the hood on when cooking at a high heat c Clean the ventilation hood frequently Grease should not be allowed to accumulate on the fan or filter d Use the proper pan size Always use cookware appropriate for the siz...

Страница 8: ...it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA The ventilation hood may become damaged if exposed to excessive heat from a gas cooktop When using the ventilation hood over a gas cooktop ensure that any burners in use are always covered by c...

Страница 9: ...its impair the proper functioning of the ventilation hood To ensure that cooking vapors are properly cleaned never use the ventilation hood without the grease filters in place There is a risk of fire if cleaning is not completed according to the instructions in this manual Please note that the heat rising from the stovetop during cooking can cause the ventilation hood to become very hot Do not tou...

Страница 10: ... do not damage electrical wiring and other hidden utilities d Ducted hoods must always be vented to the outdoors e Do not use this hood with any solid state speed control device To determine whether a ventilation hood may be operated above your cooking appliance please refer to the information provided by the appliance s manufacturer Safety regulations prohibit the installation of a ventilation ho...

Страница 11: ... into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel burning installations If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other purposes seek professional advice WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK Cleaning and maintenance Never use a steam cleaner to clean th...

Страница 12: ...nce received including interference that may cause undesired operation FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 8 20 cm between the radiator and your body Industry Canada Statement This digital apparatus does not exceed the Class B limit...

Страница 13: ... reach of children Danger of suffocation Disposal of your old appliance Do not dispose of this appliance with your household waste Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Before discarding an old appliance ensure that it presents no danger to children while being stored for disposal U...

Страница 14: ...xtraction panels and the grease filters and directed outside Recirculation mode Only DA 6596 W requires a Recirculation kit and OdorFree Charcoal Filter available as optional accessories see Technical data for more information The air is drawn in and cleaned first by the edge extraction panels and the grease filters and then by a charcoal filter The cleaned air is then recirculated back into the k...

Страница 15: ... radio contact between the cooktop and the hood for you to be able to use the Con ctivity 2 0 function see Activating Con ctivity 2 0 The cooktop transmits information about its operational status to the hood using a radio signal When a burner is turned on the cooktop lighting on the hood turns on automatically After a brief delay the ventilation hood fan also comes on During cooking the hood auto...

Страница 16: ...Guide to the appliance 16 ...

Страница 17: ...ainless steel 3 elements DRP 6520 W glass 4 elements DRP 6520 W stainless steel 4 elements g Recirculation vent only for recirculation mode h Cooktop lighting i OdorFree Charcoal Filter Optional accessory for recirculation mode j Button for cooktop lighting k On Off button for fan l Buttons for setting the fan power m Button for delayed shut down function n Filter saturation indicator ...

Страница 18: ... the total output of the cooktop i e the number of burners in operation and the power settings selected If you select a higher power setting on the cooktop or switch on multiple burners the hood will switch to a higher fan level If you select a lower power setting on the cooktop or turn off a burner the hood will accordingly switch to a lower fan level Examples for fan levels 1 to 4 Reaction time ...

Страница 19: ...Con ctivity function You can also manually select a different fan level before then Switching off Turn off all burners Over the next few minutes the ventilation hood blower setting will decrease one level at a time until the hood eventually turns off This helps to neutralize any lingering vapors and odors in the air From the Booster setting the blower switches immediately to level 3 From level 3 i...

Страница 20: ... mode If the ventilation hood has not been used for a period of approx 5 minutes after the manual selection of a fan level or If the manually selected fan level once again matches the automatic setting or If the ventilation hood fan and the cooktop have been turned off for at least 30 seconds Automatic mode will resume the next time the cooktop is turned on If you wish to manually operate the vent...

Страница 21: ...ng the blower automatically switches back to level 3 after 5 minutes Selecting the delayed shutdown time It is advisable to run the blower for a few minutes after cooking has finished This helps to neutralize any lingering vapors and odors in the air It also reduces the risk of odors and residues accumulating in the ventilation hood The delayed shutdown function enables the blower to continue runn...

Страница 22: ... increase energy consumption Activating deactivating power management Switch off the blower and the lighting Press the delayed shutdown control for approx 10 seconds until the 1 indicator appears in the blower level display Then press in turn the lighting control the control and then the lighting control When power management is turned on the 1 and B indicators will be continuously lit When it is ...

Страница 23: ...off If power management has been deactivated the ventilation hood will switch itself off automatically after 12 hours if it has been left on blower and overhead lighting To switch it back on press the On Off control or the lighting control ...

Страница 24: ...food is fried regularly A shorter cleaning interval is also recommended if the customer only cooks occasionally This will prevent grease buildup from hardening and making cleaning more difficult Select a longer cleaning interval of 40 or 50 hours if the customer uses very little fat when cooking Switch off the blower and the lighting Press the delayed shutdown control and the filter saturation con...

Страница 25: ...on by pressing the filter saturation indicator All the indicator lights go out If the new setting is not confirmed within 4 minutes the hood reverts to the previous setting Checking the filter saturation indicator Before the set operating time has run out you can check what percentage of the time has elapsed Press the On Off control to turn the blower on Press and hold the filter saturation indica...

Страница 26: ...e damage Make sure that water does not get into the ventilation hood Clean all surfaces and control buttons using a small amount of warm water and liquid dish soap Apply with a sponge cloth After cleaning wipe the surfaces dry using a soft cloth Important information for appliances with stainless steel surfaces This information does not apply to the control buttons Stainless steel surfaces can be ...

Страница 27: ...ls and the reusable metal grease filters in the appliance remove solid particles grease dust etc from the kitchen vapors preventing soiling of the hood Risk of fire Oversaturated grease filters are a fire hazard Clean the grease filters at regular intervals Cleaning intervals The grease filters and panels should be cleaned regularly at least every 3 4 weeks to avoid a buildup of grease Clean the e...

Страница 28: ... in a mild solution of hot water and dish soap Do not use undiluted dish soap Unsuitable cleaning agents Unsuitable cleaners can cause damage to the filter surfaces if used regularly Do not use any of the following Lime removers Abrasive powders or abrasive liquids Aggressive all purpose cleaners and degreaser sprays Oven sprays Cleaning the panels and grease filters in the dishwasher Place the pa...

Страница 29: ...ewdriver into the slit to disengage the locking clip Hook the panels onto the support rod Lift up the front of the panels and push them into the lock until they engage Resetting the filter saturation indicator for the grease filters Once cleaning is complete the filter saturation indicator must be reset While the blower is turned on press the filter saturation indicator for approx 3 seconds until ...

Страница 30: ...rFree Charcoal Filter To install or replace the OdorFree Charcoal Filter the grease filters must first be removed as described above Remove the OdorFree Charcoal Filter from its packaging Slide the filter into the back of the intake frame then push the front of the filter up into the frame Reinsert the grease filters and the panels When installing the filter for the first time activate the filter ...

Страница 31: ...o this press the filter saturation indicator twice with the fan turned on and hold it for approx 3 seconds until 1 is the only indicator flashing The OdorFree Charcoal Filter symbol will go out If you replace the OdorFree Charcoal Filter before the full operating time elapses Press the filter saturation indicator twice and hold it for approx 6 seconds until 1 is the only indicator flashing Disposi...

Страница 32: ... Installation materials Telescopic wall bracket for securing the ventilation system on the wall 6 screws 5 x 60 mm and 6 plugs 8 x 50 mm for securing the ventilation hood on the wall The screws and plugs are designed for use in solid walls only Use different fasteners for other wall construction types Make sure that the wall can support the load 2 M6 locknuts for mounting the appliance unit 2 scre...

Страница 33: ...allation INSTALLATION 33 DUW20 Conversion kit for recirculation mode The conversion kit contains an exhaust grille hose and hose clips not supplied but available as an optional accessory See Technical data ...

Страница 34: ...Installation INSTALLATION 34 Appliance dimensions The drawing is not to scale a Extraction b Recirculation only DA 6596 W c Air vent positioned at the top for recirculation ...

Страница 35: ...he information contained in the IMPORTANT SAFETY INSTRUCTIONS section Minimum distance S Cooking appliance Miele appliance Non Miele appliance Electric Cooktops 24 610 mm Electric Barbeques and Fryers 26 660 mm Multiburner Gas Cooktops 43 000 BTU hr 12 6 kW no burner 15 000 BTU hr 4 5 kW 26 660 mm 30 760 mm Multiburner Gas Cooktops 73 800 BTU hr 21 6 kW no burner 16 500 BTU hr 4 8 kW 30 760 mm Mul...

Страница 36: ... vapor extraction the hood must be centered over the cooktop not to the side The cooktop should be no wider than the hood Preferably it should be narrower for better extraction The mounting area must be easily accessible The ventilation hood should be easy to reach and disassemble in case a service call is necessary This should be taken into consideration when planning the position of cabinetry sh...

Страница 37: ...cluded Installation diagram To install a plywood backing Determine and mark the location of the retaining plate for the canopy as outlined on the Installation diagram Make a cutting line 3 76 mm above and 3 76 mm below the outline of the retaining plate Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder Mark a vertical cutting line along the ce...

Страница 38: ...cular when using flat ducting The ducting should be as short and straight as possible Only use wide radius bends The ducting must not be kinked or compressed All connections must be strong and airtight If the ducting has flaps these must be opened whenever the ventilation hood is switched on Any constriction of the air throughput will reduce extraction performance and increase operating noise Vent...

Страница 39: ...ensate traps for 5 125 mm or 6 150 mm diameter ducting are available as optional accessories When installing a condensate trap ensure that it is positioned vertically and as closely as possible to the ventilation hood above the exhaust vent The arrow on the casing indicates the direction of airflow Miele will not accept warranty claims for any functional defects or damage caused by inadequate duct...

Страница 40: ... connection of this appliance to your power supply please consult a licensed electrician or call Miele s Technical Service Department WARNING THIS APPLIANCE MUST BE GROUNDED Grounding Instructions WARNING Improper grounding can result in a risk of electric shock This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing a p...

Страница 41: ...the relevant operating and installation instructions Please refer to the operating instructions before starting Activate the ventilation hood first then the cooktop Activating the ventilation hood The cooktop and ventilation hood must be turned off Press and hold the delayed shutdown button 5 15 for approx 10 seconds until the 1 indicator appears in the fan level display Then press the following b...

Страница 42: ...o carry out the activation procedure once If the appliances are disconnected from the electricity supply for example during a loss of power they will still remain activated Activation failed If a wireless connection cannot be established despite activation of the Con ctivity function on the ventilation hood and cooktop the function must first be deactivated and then reactivated on both appliances ...

Страница 43: ...s you the assurance of knowing that your appliance investment is covered by 5 years of worry free ownership MieleCare is the only Extended Service Contract in the industry that guarantees repairs by a Miele Authorized Service Provider using genuine Miele parts Only genuine Miele parts installed by factory trained professionals can guarantee the safety reliability and longevity of your Miele applia...

Страница 44: ...s for recirculation mode DUW 20 conversion kit and DKF 12 900 charcoal filter Contains FCC ID 2ACUWEI8800 IC 5669C EI8800 This device complies with Part 15 of the FCC Rules and with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including inte...

Страница 45: ......

Страница 46: ......

Страница 47: ...r Service Canada Importer Miele Limited Headquarters and Miele Centre Customer Service Support Phone 888 99 MIELE 64353 info mieleusa com www mieleusa com 161 Four Valley Drive Vaughan ON L4K 4V8 www miele ca Customer Care Centre Phone customercare miele ca 800 565 6435 905 532 2272 International Headquarters Miele Cie KG Carl Miele Straße 29 33332 Gütersloh Germany ...

Страница 48: ...M Nr 11 743 460 00 en US DA 6596 W DA 6526 W ...

Отзывы: