manualshive.com logo in svg
background image

Operating and Installation
Instructions

Ventilation System
DA 5190 W

To prevent accidents
and appliance damage,
read these instructions

before

installation or use.

M.-Nr. 07 787 390

en - US, CA

Содержание DA 5190 W

Страница 1: ...Operating and Installation Instructions Ventilation System DA 5190 W To prevent accidents and appliance damage read these instructions before installation or use M Nr 07 787 390 en US CA ...

Страница 2: ...ng on off 13 Dimming the lighting 13 Grease filter timer 14 Cleaning and Care 17 Cleaning the casing 17 Grease filter 18 Active charcoal filter 20 Changing the light bulbs 21 After Sales Service 22 Installation instructions 23 Caring for the environment 25 Appliance dimensions 26 Plywood backing 29 Installation 30 Installation 32 Dismantling 32 Air extraction 33 Electrical connection 35 Technical ...

Страница 3: ...sed in a non stationary location e g on a ship WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this appliance only in the manner intended by the manufacturer If you have questions contact Miele b Before servicing or cleaning the appliance switch power off at the service panel and lock the service disconnecting means to prevent power from being swi...

Страница 4: ...lectrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults g Before discarding an old appliance disconnect it from the power supply and remove the power cord to prevent hazards Use WARNING TO REDUCE THE RISK OF A COOKTOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers may ...

Страница 5: ...fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NAFTA Do not allow children to play with or operate the appliance or its controls Supervise its use by the elderly or infirm Always turn on the hood when using the cooktop to prevent damage from condensation Never operate gas burners without cookware Turn the burner off ...

Страница 6: ...control device f Do not use an extension cord to connect the appliance to electricity Extension cords do not guarantee the required safety of the appliance e g danger of overheating g Do not install this hood over cooktops that burn solid fuel h Provided a larger distance is not given by the manufacturer of the cooktop follow the minimum safety distances between a cooktop and the bottom of the hoo...

Страница 7: ...he air pressure of the exhaust fan auto matically opens the flap blowing the inside air and cooking odors outside Recirculation mode Air is drawn through the grease filter and active charcoal filter The filtered air is then recirculated back into the kitchen through a vent at the top of the hood s chimney The active charcoal filter and the installation kit may be purchased from your Miele Before u...

Страница 8: ...Guide to the Ventilation System 8 ...

Страница 9: ... filter indicator light lights red when the grease filter needs to be cleaned The indicator light lights blue when the active charcoal filter needs to be changed The charcoal filter is only used in recirculation mode The charcoal filter timer must be activated before the first use on the hood This button is also used to reset the filter timer after cleaning the grease filter or changing the charco...

Страница 10: ...e used for a short period when frying or cooking food with a strong aroma Automatically switching back the intensive power level The intensive level 4 can be programmed to automatically switch back to level 3 after 10 minutes Turn the fan and the lights off Press and hold the Delayed Shut Down button at the same time for 10 secs The first indicator lights Press the following buttons one after anot...

Страница 11: ...ve the setting press the Delayed Shut Down button If the procedure is not stored within 4 minutes of programming the hood will automatically default to the old data Fan performance The maximum air flow capacity is 625 cfm Factors such as narrow duct diameter and bends will affect this value Level 1 operates at 40 capacity Level 2 operates at 60 capacity Level 3 operates at 80 capacity Level 4 oper...

Страница 12: ... still running Press once 5 minute delay left indicator lights Press twice 15 minute delay right indicator lights To cancel the feature press the Delayed Shut Down button again The fan will not turn off automatically Turning off the fan Press the On Off button to turn the fan off The indicator goes out Automatic Safety Shut Off The fan will turn off automatically 10 hours after the last button was...

Страница 13: ...The light button indicator will go out Dimming the lighting The brightness of the lighting can be adjusted While the lighting is turned on press and hold the light button The lighting will dim until the button is released If the button is pressed again the lighting will brighten until the button is released If the button is pressed continuously the light will cycle between bright and dark Press th...

Страница 14: ...l filter timer The charcoal filter indicator will light blue once the selected time has elapsed The charcoal filter must then be replaced and the timer reset To do this press the grease charcoal filter button for about 3 seconds The indicator will go out Checking the filter timer To check the percentage of time already used Press the On Off button to turn the fan on For the grease filter timer Pre...

Страница 15: ...fficult Press the On Off button to turn off the fan Press the Delayed Shut Down and grease charcoal filter button at the same time The red indicator for the grease filter timer and one of the indicators will flash The lit indicator shows the programmed time 1st indicator from the left 20 hours 2nd indicator from the left 30 hours 3rd indicator from the left 40 hours 4th indicator from the left 50 ...

Страница 16: ...filter buttons at the same time The blue indicator for the grease charcoal filter and one of the indicators will flash The lit indicator shows the programmed time 1st indicator from the left 120 hours 2nd indicator from the left 180 hours 3rd indicator from the left 240 hours 4th indicator from the left endless Use the button to select the desired time Store the selection by pressing the grease ch...

Страница 17: ...controls Water could penetrate into the electronics and cause damage Glass surfaces can be cleaned using glass cleaner Avoid cleaning agents containing soda acids chlorides or thinners abrasive cleaning agents e g powder or cream cleansers abrasive sponges e g pot scourers or sponges which have been previously used with abrasive cleaning agents limescale removers These will damage the surface The ...

Страница 18: ...be cleaned every 3 4 weeks or whenever the grease filter indicator lights red A dirty filter is a fire hazard Removing the grease filter To remove the grease filter pull the locking clip forward Lower the filter 45 unhook it at the rear and take it out Support the grease filter so that it does not fall onto the cooktop Cleaning and Care 18 ...

Страница 19: ...manent discoloration of the filter surface Performance of the filter will not be affected by this discoloration After cleaning the filter can be placed on a towel to air dry While the filter is removed clean any dirt or grease from the interior casing to prevent the risk of fire When putting the grease filter back make sure that the locking clip is facing the cooking surface If the filter is incor...

Страница 20: ...grease filter Before using Program the charcoal filter timer see Operation Reprogramming the charcoal filter timer Replace the active charcoal filter when the grease charcoal filter indicator lights blue at least every 6 months or when they no longer absorb odors efficiently After replacing the charcoal filter press the grease charcoal filter button twice and hold for about 3 seconds to reset the ...

Страница 21: ...s Do not attempt to change the bulbs until they have had sufficient time to cool Do not touch the bulb surface Fingerprints or body oils deposited on the bulb will decrease its life Please follow the manufacturer s instructions To change the halogen bulb first gently press the light cover The cover will open and can now be flipped down Pull the halogen bulb from its socket then insert a new bulb t...

Страница 22: ...ustry that guarantees repairs by a Miele Authorized Service Provider using genuine Miele parts Only genuine Miele parts installed by factory trained professionals can guarantee the safety reliability and longevity of your Miele appliance Please note that unless expressly approved in writing by Miele s Service department Extended Service Contracts offered by other providers for Miele products will ...

Страница 23: ...g this ventilation system The installation steps are described in the enclosed Installation Diagram Leave these instructions with the appliance for the consumer user Information is subject to change Please refer to our website to obtain the most current product specification technical warranty information ...

Страница 24: ...24 ...

Страница 25: ...sed of safely and kept out of the reach of babies and young children Danger of suffocation Disposal of an old appliance Old appliances may contain materials that can be recycled Please contact your local recycling center about the possibility of recycling these materials Before discarding an old appliance disconnect it from the electrical supply and cut off the power cord to prevent it from becomi...

Страница 26: ...culation mode 3 Recirculation vent installed upwards 4 and 5 Installation area Wall ceiling area respectively for vent hole and outlet installation For recirculation mode only 4 and only outlet installation Appliance dimensions 26 ...

Страница 27: ... s body height i e a comfortable height for the user However the greater the distance the less effectively cooking odors are drawn in If the hood is fitted flush to the ceiling regard the possible unit height when selecting the installation height Standard unit height H Air extraction 28 40 3 8 710 1025 mm Recirculation 33 45 11 16 840 1160 mm To fit the lower chimney section the distance between ...

Страница 28: ... Single burner Wok 20 500 BTU 6 KW 26 660 mm 30 760 mm All other gas cooktops 30 760 mm If several gas surfaces are installed under the hood the total output must be considered when determining the minimum safety distance Be sure to follow the minimum safety distances given by the gas cooktop manufacturer to easily flammable materials e g upper cabinets If local building codes require a greater sa...

Страница 29: ...nstall a plywood backing Determine and mark the location of the retaining plate for the canopy as outlined on the Installation diagram Make a cutting line 3 76 mm above and 3 76 mm below the outline of the retaining plate Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder Mark a vertical cutting line along the center of each stud CAUTION When c...

Страница 30: ...Installation 30 ...

Страница 31: ...clips optional accessory 1 lever for dismantling the chimney Installation instruction diagram CAUTION To avoid risk of hand or other injury avoid contact with sharp edges during the assembly and installation process 6 large headed screws 5 x 40 mm for securing the retaining plates and the canopy S8 wall anchors included in the packaging are not for use in USA 1 small headed screw 5 x 40 mm 1 cap f...

Страница 32: ...tling If the hood needs to be disassembled follow the instructions on the Installation diagram in the reverse order A lever is enclosed for easier removal of the chimney extension After removing the screws from the chimney slide the lever between the chimney and the chimney extension and gently apply pressure to ease the chimney from its hooks Installation 32 ...

Страница 33: ... Use smooth or flexible pipework made from approved non flammable materials for exhaust ducting To achieve the most efficient air extraction and quietest noise levels consider the following The diameter of the ductwork should not be less than 6 150 mm If flat ducting is used the cross section must not be smaller than the cross section of the ventilation exhaust The ducting should be as short and s...

Страница 34: ...Important If the ductwork runs through rooms ceilings garages etc where temperature variations exist it may need to be insulated to reduce condensation Condensate trap optional accessory In some cases a condensate trap may also be required to collect and evaporate any condensate which may occur This optional accessory is available for ducts 5 125 mm and 6 150 mm in diameter When installing a conde...

Страница 35: ...l connection of this appliance to your power supply please consult a licensed electrician or call Miele s Technical Service Department WARNING THIS APPLIANCE MUST BE GROUNDED Grounding Instructions This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing a path of least resistance This appliance is equipped with a cord ha...

Страница 36: ...Maximum load 430 W Fan 350 W Overhead lighting 4 x 20 W Voltage 120 V Frequency 60 Hz Circuit rating 15 A Weight 61 5 lb 27 9 kg Technical data 36 ...

Страница 37: ...37 ...

Страница 38: ...38 ...

Страница 39: ...39 ...

Страница 40: ...Alteration rights reserved 1711 INFORMATION IS SUBJECT TO CHANGE PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS TECHNICAL WARRANTY INFORMATION M Nr 07 787 390 02 ...

Отзывы: