background image

,

Before installation, it is important

to read the information given on the
following pages as well as the
"Appliance dimensions" and the
"Warning and Safety instructions" at
the beginning of this booklet.
This is particularly crucial when
using the cooker hood at the same
time as a heating appliance that
relies on oxygen from the same
room to avoid the danger of toxic
fumes building up.

Installation instructions

See enclosed Installation sheet for
instructions on how to install this
appliance.

Assembly parts

4 screws 8 x 60 mm

with

4 washers

and

4 plugs S 10

to secure the cover plate

to the ceiling

,

The screws and plugs are for use

in concrete ceilings only.
For other types of construction,
alternative suitable fixings will be
required.
Make sure the ceiling is strong
enough to bear the weight of the
cooker hood.

2 screws M4 x 8 mm

for securing the tower.

4 spacers

to use in the event of an

uneven ceiling.

1 floating bracket

to give a choice of

position for the exhaust cut-out in the
ceiling.

1 hose clip

for securing the exhaust

ducting to the exhaust stub.

Special installation instructions
for recirculation mode

In order to use the cooker hood in
recirculation mode, it has to be fitted
with a special conversion kit which is
available from the Spare Parts
Department (see "Technical data"). It is
supplied with its own fitting instructions.

After the cooker hood has been
installed, the charcoal filter has to be
fitted, and the operating hours counter
has to be set. See "Cleaning and Care"
and "Filter operating hours counter".

Installation

30

Содержание DA 420 V EXT

Страница 1: ...tions Cooker hoods DA 420 V DA 420 V EXT DA 424 V DA 424 V EXT To avoid the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time M Nr 09 200 980 en GB ...

Страница 2: ...witch the lighting off 17 Filter operating hours counter 18 Adjusting the height of the canopy 21 Cleaning and care 22 Housing 22 Grease filters 23 Fitting and replacing the charcoal filter 25 Changing a halogen lamp 26 After Sales Service 27 Appliance dimensions 28 Safety distance between hob and cooker hood S 29 Installation 30 Installation instructions 30 Assembly parts 30 Special installation ...

Страница 3: ...Operation with DSM 400 control module 34 Potential free connection 34 Connection to a light switch 34 Connection for air extraction 35 Condensate trap 36 Silencer 37 Technical data 38 Contents 3 ...

Страница 4: ...pliance Electrical and electronic appliances often contain materials which if handled or disposed of incorrectly could be potentially hazardous to human health and to the environment They are however essential for the correct functioning of your appliance Please do not therefore dispose of it with your household waste Please dispose of it at your local community waste collection recycling centre o...

Страница 5: ... the manufacturer and could be dangerous Miele cannot be held liable for damage resulting from incorrect or improper use or operation This appliance is not intended for use by people with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they are supervised whilst using it or have been shown how to use it correctly by a person responsible for their safety Sa...

Страница 6: ...nce may only be used when it has been fully installed Only open the housing as described in the instructions given in the installation sheet and in the Cleaning and care section of this booklet Under no circumstances should any other parts of the housing be opened Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operational faul...

Страница 7: ... the same time as other heating appliances that depend on the air from the room Warning danger of toxic fumes Great care should be taken when using the cooker hood at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room Such appliances include gas oil wood or coal fired boilers and heaters continuous flow or other water heaters g...

Страница 8: ...ll vents or by other technical measures such as ensuring that the cooker hood can only be switched on when the heating appliance is switched off or vice versa A ventilation brick alone is not generally sufficient to ensure safe ventilation The overall ventilation condition of the dwelling must be taken into account If in any doubt the advice of a competent builder or for gas a qualified gas fitter...

Страница 9: ...condensation may collect in the hood which could cause corrosion When cooking with oil or fat chip pans and deep fat fryers etc do not leave the pans unattended Never leave an open grill unattended when grilling Overheated oil and fat can ignite and could set the cooker hood on fire Do not use the cooker hood without the filters in place This way you will avoid the risk of grease and dirt getting ...

Страница 10: ...olid fuel stoves All ducting pipework and fittings must be of non flammable material These can be obtained from the Miele Spare Parts department or from builders merchants The appliance must not be connected to a chimney or vent flue which is in use Neither should it be connected to ducting which ventilates rooms with fireplaces If exhaust air is to be extracted into a chimney or ventilation duct ...

Страница 11: ... required which are available as optional accessories see Technical Data The air is drawn in and cleaned first by the grease filters and then by a charcoal filter The cleaned air is then recirculated back into the kitchen through grilles in the top of the cooker hood telescopic tower Before using the cooker hood in recirculation mode ensure that the charcoal filter is in place See Cleaning and car...

Страница 12: ...Guide to the appliance 12 ...

Страница 13: ... to be cleaned This control is used to reset the operating hours counter after cleaning the grease filters see Cleaning and care It can also be used to check and alter the operating hours counter nTouch control for the charcoal filter DA 420 V only The indicator lamp for the charcoal filter touch control lights up when the charcoal filter used in recirculation mode needs to be replaced For this to...

Страница 14: ...er hood hob lighting also comes on and then after a short time the fan switches on During cooking the cooker hood automatically sets its power level according to the number of cooking zones in operation and their power levels After switching the hob off the fan and the hob lighting will switch off automatically after a period of time For detailed information about this function please read the sep...

Страница 15: ...frying or cooking food with a strong aroma you may wish to select the Intensive setting for a short period Automatic switch off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III To set this option both the fan and the hob lighting must be switched off Press the run on option touch control for approximately 10 ...

Страница 16: ...advisable to run the fan for a few minutes after cooking has finished to neutralise any lingering odours in the air whether you are using air extraction or recirculation mode The fan can be set to switch off automatically after either 5 or 15 minutes After cooking has finished press the run on option touch control whilst the fan is still running Press once The fan will switch off after 5 minutes l...

Страница 17: ...brightness will gradually dim until you release the touch control Press the touch control in again to increase the brightness to the level required and then release it If you keep the touch control pressed in the light will continually change between bright and dim To switch the lighting off Press the hob lighting touch control briefly to switch the lighting off The indicator lamp will go out Safe...

Страница 18: ...trol will light up after the cooker hood has operated for the number of hours set The charcoal filter must then be replaced with a new one Afterwards the filter operating hours counter must be reset Press the charcoal filter touch control for about 3 seconds The indicator lamp for the touch control will go out Reading the filter operating hours counter To check the percentage of time set already u...

Страница 19: ...be lengthened or shortened you can choose 20 30 40 or 50 hours Press the On Off touch control to switch the fan off Press the run on option touch control and the grease filter touch control at the same time The indicator lamp for the grease filter touch control and one of the touch control lamps will flash The control lamps show the time which has been set 1st lamp from the left 20 hours 2nd lamp ...

Страница 20: ...n touch control and the charcoal filter touch control at the same time The indicator lamp for the charcoal filter touch control and one of the lamps above the touch controls will flash The control lamps show the time which has been set 1st lamp from the left 120 hours 2nd lamp from the left 180 hours 3rd lamp from the left 240 hours 4th lamp from the left unlimited Use the touch controls to select...

Страница 21: ...more working space above the hob by raising the canopy when required The height of the canopy can be adjusted by up to 260 mm this can be extended to 300 mm see Installation The canopy can be raised or lowered by touching the Up or Down controls briefly Pressing the control again stops the canopy If it is not stopped the canopy will automatically be raised or lowered to its fullest extent Repeated...

Страница 22: ...out soft sponge or cloth Wipe the surfaces dry using a soft cloth Do not use too much water when cleaning the controls Water could penetrate into the electronics and cause damage Avoid cleaning agents containing soda acids chlorides or solvents abrasive cleaning agents e g powder cleaners or cream cleaners and abrasive sponges as well as pot scourers or sponges which have been used previously with...

Страница 23: ...kitchen vapours preventing soiling of the cooker hood The grease filters should be cleaned regularly at least every 3 4 weeks to avoid a build up of grease However they should be cleaned immediately if the grease filter touch control lamp comes on An oversaturated filter is a fire hazard To take out the grease filters release the locking clip on the filter lower the filter 45 unhook it at the back...

Страница 24: ...surface However this will not affect the functioning of the filters in any way After cleaning leave the filters to dry on an absorbent surface before replacing them When removing the filters for cleaning also clean off any residues of oil or fat from the now accessible housing to prevent the risk of these catching fire When putting the grease filters back in position ensure that the locking clips ...

Страница 25: ...g Insert the charcoal filter into the canopy When fitting for the first time Set the operating hours counter to suit your requirements see Operation Always replace the charcoal filter im mediately if the indicator lamp for the charcoal filter touch control lights up or if it is no longer effective in absorbing kitchen odours It should however be replaced at least every 6 months Used charcoal filte...

Страница 26: ...itched off Let them cool down before you change them To access the halogen lamp push the lamp cover gently upwards The cover will open and can be pulled down Pull the old halogen lamp out of the connection socket Using a cloth or glove push the new lamp 12 V 20 W G4 cap carefully into the connection socket Please follow the manufacturer s instructions Push the cover back up and make sure it clicks...

Страница 27: ...ease filter is removed For G B Please note that telephone calls may be monitored and recorded for training purposes N B A call out charge will be applied for service visits where the problem could have been resolved as described in these instructions Guarantee For information on the appliance guarantee specific to your country please contact Miele See back cover for contact details In the U K your...

Страница 28: ...this height range as standard 3 Height range for appliance in recirculation mode 4 Possible height range for appliance in extraction mode see Installation 5 Ventilation grille positioned at the top for recirculation Exhaust connection C 150 mm not needed for recirculation mode The exhaust connection in the ceiling plate is not fixed in the middle which means that the hood can also be installed whe...

Страница 29: ...pen grill or deep fat fryer 650 mm above gas hobs and cookers If this cooker hood is installed above a Miele Wok CS 1028 CombiSet appliance a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the cooker hood For further advice see Warning and Safety instructions If the distance falls below the recommended safety distance when the canopy is lowered the ma...

Страница 30: ... types of construction alternative suitable fixings will be required Make sure the ceiling is strong enough to bear the weight of the cooker hood 2 screws M4 x 8 mm for securing the tower 4 spacers to use in the event of an uneven ceiling 1 floating bracket to give a choice of position for the exhaust cut out in the ceiling 1 hose clip for securing the exhaust ducting to the exhaust stub Special i...

Страница 31: ...t range is required the canopy will be lowered further A maximum appliance height of 1030 mm is possible for extraction mode only not possible for recirculation mode Install the cooker hood according to the installation instructions supplied Press the Down button to lower the canopy The canopy will be lowered to its fullest extent Remove the grease filters Remove the cooker hood tower fixing screw...

Страница 32: ... is required b lower the canopy A maximum appliance height of 1030 mm is possible Secure the limit switch opposite the guide on the telescopic tower see illustration Raise and lower the canopy and check that the limit switch is working Remove the safety screw and push the tower downwards Then secure the tower with the safety screw again Replace the grease filters Installation 32 dai2260 dai2262 da...

Страница 33: ... Connection of this appliance should be made via a suitable isolator or a double pole fused spur connection unit which complies with national and local safety regulations and the On Off switch should be easily accessible after the appliance has been built in When switched off there must be an all pole contact gap of 3 mm in the switch including switch fuses and relays according to EN 60 335 If the...

Страница 34: ...return flap b which is connected to the central extraction unit c Components used in the central ducting system are not supplied by Miele If in any doubt the advice of a competent builder or for gas a Gas Safe installer must be sought Connection to a light switch The control module can be used to switch on the cooker hood lighting and also to dim it via a light switch in the house Installation The...

Страница 35: ...se an underpressure which could result in the exhaust ducting distorting To achieve the greatest possible air extraction with the lowest noise level please note the following To ensure efficient air extraction the diameter of the exhaust ducting should not be less than 150 mm If flat ducting is being used the cross sectional area must not be smaller than the cross sectional area of the exhaust con...

Страница 36: ...ssed The exhaust ducting will need to be suitably insulated Condensate trap optional accessory In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur Condensate traps are available for C 125 mm or C 150 mm ducting When installing a condensate trap ensure that it is positioned vertically an...

Страница 37: ... air extraction with external motor To minimise noise from the motor in the kitchen the silencer should be positioned in front of the external motor b if possible or if the ducting is long then in the ducting above the cooker hood itself c In the case of an external motor placed inside the house fitting a silencer behind the external motor d reduces the noise of the motor outside the house In all ...

Страница 38: ...an performance Extraction power according to EN 61591 Extraction system C 150 mm Level I 200 m3 h Level II 320 m3 h Level III 480 m3 h Intensive Setting 700 m3 h Recirculation with charcoal filter Level I 150 m3 h Level II 260 m3 h Level III 400 m3 h Intensive Setting 500 m3 h Optional extras for recirculation mode Conversion Kit DUI 31 Miele charcoal filter DKF 12 1 For EXT models the connected l...

Страница 39: ...39 ...

Страница 40: ...Alteration rights reserved 3011 M Nr 09 200 980 00 ...

Отзывы: