Operating and Installation Instructions
Ventilation Hood

To prevent accidents and damage to the appliance, you 

must

 read

these instructions before installing the appliance and using it for the first
time.

en-US

M.-Nr. 10 597 860

Содержание DA 399-7

Страница 1: ...nd Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance you must read these instructions before installing the appliance and using it for the first time en US M Nr 10 597 860 ...

Страница 2: ...l Filter 21 Disposing of charcoal filters 21 Changing a light bulb 22 Installation 23 Before installation 23 Removing the protective film 23 Installation Instructions 23 Disassembly 23 Installation parts 24 Appliance dimensions 26 Distance between cooktop and ventilation hood S 27 Installation recommendations 28 Drilling diagram for wall mounting 28 Plywood backing 29 To install a plywood backing ...

Страница 3: ... CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors This appliance is intended for residential use only Use only as described in these operating instructions This ventilation hood is not intended for outdoor use It must only be used to extract and clean vapors produced during cooking Any other use occurs at the owner s own risk This appliance...

Страница 4: ... at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally If the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Unauthorized installation maintenance and repairs can cause considerable danger for the user Installation maintenance and repairs must only be carried out...

Страница 5: ...after it has been properly installed This ventilation hood may not be used in non stationary locations e g on a ship Adequate ventilation must be provided when the hood is operated simultaneously with devices that burn gas or other fuels Only open the housing as described in the enclosed Installation diagram and in the Cleaning and care section of this manual Under no circumstances should any othe...

Страница 6: ...s may ignite Heat oils slowly on low or medium settings b Always turn the hood on when cooking at a high heat c Clean the ventilation hood frequently Grease should not be allowed to accumulate on the fan or filter d Use the proper pan size Always use cookware appropriate for the size of the cooking area Never use an open flame beneath the ventilation hood To avoid the risk of fire do not flambé or...

Страница 7: ...rners in use are always covered by cookware Turn burners off when removing the cookware even if doing so for just a short time Select cookware that is suitable for the size of the burner Adjust the flame so that it never extends up the sides of the cookware Avoid overheating the cookware e g when cooking with a wok Always turn the ventilation hood on whenever a burner is in use to prevent damage f...

Страница 8: ... is not completed according to the instructions in this manual Please note that the heat rising from the stovetop during cooking can cause the ventilation hood to become very hot Do not touch the housing or the grease filters until the ventilation hood has cooled down ...

Страница 9: ... do not damage electrical wiring and other hidden utilities d Ducted hoods must always be vented to the outdoors e Do not use this hood with any solid state speed control device To determine whether a ventilation hood may be operated above your cooking appliance please refer to the information provided by the appliance s manufacturer Safety regulations prohibit the installation of a ventilation ho...

Страница 10: ...ipes or tubes made of non flammable material These can be obtained from your Miele dealer or from Miele Technical Service Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel burning installations If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other p...

Страница 11: ...er use a steam cleaner to clean the ventilation hood The steam can reach the electrical components and cause a short circuit Accessories Use only genuine original Miele parts If parts or accessories from other manufacturers are used the warranty will become void ...

Страница 12: ...or the proper functioning and safe use of the equipment Handling these materials improperly by disposing of them in your household waste can be harmful to your health and the environment Therefore please do not dispose of your old appliance with regular household waste and follow local regulations on proper disposal Consult with local authorities dealers or Miele in order to dispose of and recycle...

Страница 13: ...hen the ventilation hood is turned on the non return flap opens so that the exhaust air can be transported outside without any obstruction A non return flap has been provided with the hood in case your ducting does not have one It is inserted into the outlet duct collar of the fan Recirculation mode The recirculation mode requires a recirculation kit and OdorFree Charcoal Filter available as optio...

Страница 14: ...Guide to the appliance 14 ...

Страница 15: ...rease filter f Recirculation vent only for recirculation mode g Overhead LED ClearView lighting h OdorFree Charcoal Filter Optional accessory for recirculation mode i On Off button for fan j Buttons for setting the fan power k On Off touch control for the overhead LED ClearView lighting ...

Страница 16: ...atic Booster setting switch off You have the option to program the booster level to ensure the fan will always switch back to level 3 automatically after 10 minutes To do this turn off the fan and the overhead lighting first Press the and buttons at the same time for approx 10 seconds until 1 lights up Then press the following buttons in order the lighting button Followed by the button and then th...

Страница 17: ...n be turned on and off separately from the blower To do this press the lighting control The symbol will light up when the overhead lighting is turned on Safety switch off If the ventilation hood is switched on but not used for 10 hours the fan shuts off automatically The cooktop lighting remains switched on Pressing the On Off button will switch the fan back on again ...

Страница 18: ...Avoid the following Cleaners containing soda acid or chloride or cleaners containing solvents Abrasive sponges e g pot scourers or sponges which have been previously used with abrasive cleaning agents Special instructions for stainless steel surfaces does not apply to control buttons Stainless steel surfaces can also be cleaned using a non abrasive stainless steel cleaner available from Miele To p...

Страница 19: ...rom becoming dirty The grease filters must be cleaned at regular intervals Heavily soiled grease filters hinder air extraction and will lead to increased levels of soiling in the ventilation hood and in the kitchen Risk of fire Oversaturated grease filters are a fire hazard Clean the grease filters at regular intervals Cleaning intervals Accumulated grease solidifies over a longer period of time a...

Страница 20: ... slightly inclined in the lower basket Ensure the spray arm is not obstructed Use a commonly available household dishwashing detergent In a Miele dishwasher use the Normal program Depending on the detergent used cleaning the filters in a dishwasher may cause the inside filter surfaces to become discolored However this will not affect the functioning of the grease filters in any way After cleaning ...

Страница 21: ...ails or directly from Miele How to install replace a charcoal filter Remove the grease filters before fitting or replacing a charcoal filter Take the charcoal filter out of its packaging Slide the filter into the back of the intake frame then push the front of the filter up into the frame Reinsert the grease filters When to change the OdorFree Charcoal Filter Replace the charcoal filter when it no...

Страница 22: ...n lamps may become damaged due to the high generation of heat Disconnect the hood from the electrical supply before replacing the bulbs see IMPORTANT SAFETY INSTRUCTIONS Remove the grease filters Turn the bolt counterclockwise as far as it will go The halogen lamp will then drop down towards you Turn the bulb counter clockwise and pull it out Replace the new bulb in reversed order Please observe t...

Страница 23: ...lling the housing components It can be peeled off easily without any additional tools Installation Instructions Please refer to the accompanying installation sheet for instructions on how to install the appliance Disassembly If the device ever needs to be disassembled follow the installation sheet instructions in reverse order A lever is provided to assist with the removal of the chimney Unscrew t...

Страница 24: ...Installation 24 Installation parts ...

Страница 25: ... recirculation mode contains diverter aluminum hose and hose clamps not contained in scope of delivery available as optional accessory see Technical Data 8 screws x 2 5 x 60 mm 8 plugs x 2 8 x 50 mm for attaching to the wall not for use in USA CDN The screws and plugs are designed for use in solid walls only Use different fasteners for other wall construction types Make sure that the wall can supp...

Страница 26: ...Installation 26 Appliance dimensions The drawing is not to scale a Extraction b Recirculation c Air vent positioned at top for recirculation ...

Страница 27: ...nformation contained in the IMPORTANT SAFETY INSTRUCTIONS section Minimum distance S Cooking appliance Miele appliance Non Miele appliance Electric Cooktops 24 610 mm Electric Barbeques and Fryers 26 660 mm Multiburner Gas Cooktops 43 000 BTU hr 12 6 kW no burner 15 000 BTU hr 4 5 kW 26 660 mm 30 760 mm Multiburner Gas Cooktops 73 800 BTU hr 21 6 kW no burner 16 500 BTU hr 4 8 kW 30 760 mm Multibu...

Страница 28: ...ktop should be no wider than the hood Preferably it should be narrower for better extraction The mounting area must be easily accessible The ventilation hood should be easy to reach and disassemble in case a service call is necessary This should be taken into consideration when planning the position of cabinetry shelves ceilings or decorative elements in the vicinity of the ventilation hood Drilli...

Страница 29: ...Installation diagram To install a plywood backing Determine and mark the location of the retaining plate for the canopy as outlined on the Installation diagram Make a cutting line 3 76 mm above and 3 76 mm below the outline of the retaining plate Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder Mark a vertical cutting line along the center of...

Страница 30: ...e used the cross section should not be smaller than that of the exhaust connector The exhaust duct should be as short and straight as possible If elbows are needed make sure they have a large radius The exhaust duct itself must not be kinked or compressed Make sure that all connections are secure and airtight Remember that any constriction of the airflow will reduce extraction performance and incr...

Страница 31: ...ioned vertically and if possible directly above the hood outlet duct collar The arrow on the housing indicates the direction of airflow Reducing Collar optional accessory If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed It reduces the air flow to less than 400 CFM Check local building codes for max CFM r...

Страница 32: ...connection of this appliance to your power supply please consult a licensed electrician or call Miele s Technical Service Department WARNING THIS APPLIANCE MUST BE GROUNDED Grounding Instructions WARNING Improper grounding can result in a risk of electric shock This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing a pa...

Страница 33: ...iance investment is covered by 5 years of worry free ownership MieleCare is the only Extended Service Contract in the industry that guarantees repairs by a Miele Authorized Service Provider using genuine Miele parts Only genuine Miele parts installed by factory trained professionals can guarantee the safety reliability and longevity of your Miele appliance Please note that unless expressly approve...

Страница 34: ...pply voltage frequency 120 V AC 60 Hz Fuse 15 A Power cord length 2 5 ft 0 75 m Weight DA 398 7 55 3 lbs 25 1 kg DA 399 7 57 2 lbs 26 kg Optional accessory for recirculation mode DUW 20 conversion kit to change from extraction mode to recirculation mode and OdorFree Charcoal Filter DKF 12 900 ...

Страница 35: ...Service Canada Importer Miele Limited Headquarters and Miele Centre 800 843 7231 609 419 4298 Technical Service Support Phone Fax TechnicalService mieleusa com 161 Four Valley Drive Vaughan ON L4K 4V8 www miele ca 800 999 1360 888 586 8056 Customer Care Centre Phone customercare miele ca 800 565 6435 905 532 2272 International Headquarters Miele Cie KG Carl Miele Straße 29 33332 Gütersloh Germany ...

Страница 36: ...M Nr 10 597 860 03 en US DA 398 7 DA 399 7 ...