manualshive.com logo in svg
background image

Operating and installation instructions

Cooker hood
DA 396
DA 399

To avoid the risk of accidents
or damage to this appliance
it is

essential

to read these

instructions before it is installed
and used for the first time.

M.-Nr. 06 417 570

en - GB, AU, NZ

Содержание DA 396

Страница 1: ...tion instructions Cooker hood DA 396 DA 399 To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time M Nr 06 417 570 en GB AU NZ ...

Страница 2: ...tant for appliances with lacquered housing 14 Grease filters 14 Fitting and replacing the charcoal filter 16 Changing a halogen lamp 17 Appliance dimensions 18 Safety distance between hob and cooker hood S 19 Installation 20 Assembly parts 20 Installation instructions 22 Protective foil 22 Dismantling 22 Electrical connection 23 Connection for air extraction 24 Condensate trap 25 After Sales Servi...

Страница 3: ...Electrical and electronic appliances often contain materials which if handled or disposed of incorrectly could be potentially hazardous to human health and to the environment They are however essential for the correct functioning of your appliance Please do not therefore dispose of it with your household waste Please dispose of it at your local community waste collection recycling centre or contac...

Страница 4: ... knowledge unless they are supervised whilst using it or have been given instruction concerning its use by a person responsible for their safety Safety with children This appliance is only intended for use by adults who have read these instructions This appliance is not a toy To avoid the risk of injury keep children well away and do not allow them to play with it or to use the controls They will ...

Страница 5: ... care section of this booklet Under no circumstances should any other parts of the housing be opened Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operational faults Installation maintenance and repairs may only be carried out by a Miele authorised person in accordance with current national and local safety regulations Repair...

Страница 6: ... appliances that depend on the air from the room Warning danger of toxic fumes Great care should be taken when using the cooker hood at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room Such appliances include gas oil wood or coal fired boilers and heaters continuous flow or other water heaters gas hobs cookers or ovens which ...

Страница 7: ... account If in any doubt the advice of a competent builder or for gas a qualified gas fitter Corgi registered in the UK must be sought If the only way of ensuring adequate ventilation is via an open window then a window contact switch should be fitted The window contact switch ensures that the cooker hood can only operate when the window is opened sufficiently The cooker hood simply needs a conver...

Страница 8: ...when grilling Overheated oil and fat can ignite and could set the cooker hood on fire Do not use the cooker hood without the filters in place This way you will avoid the risk of grease and dirt getting into the appliance and hindering its smooth operation The filters should be regularly cleaned or changed as appropriate Saturated filters are a fire hazard See Cleaning and care Do not use a steam c...

Страница 9: ... to ducting which ventilates rooms with fireplaces If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other purposes seek professional advice Accessories Only use genuine Miele spare parts and accessories with this appliance If spare parts or accessories from other manufacturers are used this will invalidate the guarantee and Miele cannot accept liability The m...

Страница 10: ...Guide to the appliance 10 ...

Страница 11: ... setting Depending on the intensity of the cooking vapours levels 1 to 3 are usually sufficient for normal cooking For short periods of intensive cooking vapours e g when searing meat you may wish to select the Intensive Setting IS It is advisable to run the fan for a few minutes after cooking is finished to neutralise any lingering odours in the air whether you are using air extraction or recircu...

Страница 12: ...e flap is closed when the cooker hood is switched off When the cooker hood is switched on the non return flap opens for the cooking vapours to be ducted away air recirculation available as an optional extra with a conversion kit and charcoal filter see Technical Data The air is drawn in and cleaned first by the grease filters and then by a charcoal filter The cleaned air is then recirculated back ...

Страница 13: ...ing a soft cloth Do not use too much water when cleaning the controls Water could penetrate into the electronics and cause damage E Cloth A microfibre E Cloth is available from the Miele UK Spare Parts Department which is suitable for cleaning surfaces such as stainless steel glass plastic and chrome without the use of chemicals Avoid cleaning agents containing soda acids chlorides or solvents abr...

Страница 14: ...n cleaning earlier in this section Do not use stainless steel cleaning agents on the controls Grease filters Re usable metal filters are fitted which remove solid particles oil dust etc from the kitchen vapours preventing soiling of the cooker hood To avoid the build up of grease the grease filters should be cleaned every 3 4 weeks An oversaturated filter is a fire hazard To take out the grease fi...

Страница 15: ...ed select the Sensor wash programme Use a mild dishwasher detergent Depending on the cleaning agent used cleaning the filters in a dishwasher can cause permanent discolouration to the surface However this will not affect the functioning of the filters in any way After cleaning leave the filters to dry on an absorbent surface before replacing them When removing the filters for cleaning also clean o...

Страница 16: ...artment See back cover for contact details and Technical data for the model number of the filter Before fitting or replacing a charcoal filter the grease filters must first be taken out see previous section for instructions on how to do this Take the charcoal filter out of its packaging Fit the charcoal filter into the bracket Replace the charcoal filter when it no longer absorbs kitchen odours ef...

Страница 17: ... remain hot for some time after being switched off Do not touch the surface directly when changing a lamp as grease particles from your fingers will adhere to the surface and damage it Please follow the manufacturer s instructions First remove the grease filters from the cooker hood Now turn the thumb screw anti clockwise This releases the halogen lamp partially from its housing Turn the halogen l...

Страница 18: ...ired for recirculation mode cooker hoods The shaded area represents the wall or ceiling area for the vent cut out and for fitting the connection socket For recirculation mode only a connection socket needs to be fitted Connection for air extraction C 150 mm or C 125 mm with reducing collar Appliance dimensions 18 ...

Страница 19: ...iSet appliance a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the cooker hood See Warning and Safety instructions for further information When deciding on the safety distance between the hob and cooker hood please note that a distance of 650 mm above electric cookers hobs may be preferable to give more working space under the hood Account should als...

Страница 20: ...Assembly parts Installation 20 ...

Страница 21: ...de including directional unit and flexible aluminium hose this is not included but is available as an optional extra see Technical Data Installation instructions 7 screws 5 x 40 mm and 7 x S 8 plugs for securing the retaining plates to the wall The screws and plugs are designed for use in solid walls For other types of wall construction alternative suitable fixings will be required Make sure the w...

Страница 22: ...uctions on how to install this appliance Protective foil on stainless steel appliances The housing components have protective foil around them to prevent them being damaged during transport Please remove this foil before fitting the housing components It can be peeled off easily Dismantling Should the appliance ever need to be dismantled follow the installation instructions in reverse order as des...

Страница 23: ...ppliance should be made via a suitable isolator or a double pole fused spur connection unit which complies with national and local safety regulations and the On Off switch should be easily accessible after the appliance has been built in When switched off there must be an all pole contact gap of 3 mm in the switch including switch fuses and relays according to EN 60335 If the switch is not accessi...

Страница 24: ...traction will be less efficient Only reduce the diameter of the ducting if absolutely necessary e g where narrower ducting has already been installed Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable materials for extraction connection If the exhaust ducting is secured to the exhaust stub by a hose cl...

Страница 25: ...te trap optional extra In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur Condensate traps are available for C 125 mm or C 150 mm ducting When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection The arrow on the hou...

Страница 26: ... Miele Customer Contact Centre see back cover for address When contacting your Dealer or Miele please quote the model and serial number of your appliance These are shown on the data plate which is visible when the grease filter is removed For G B Please note that telephone calls may be monitored and recorded for training purposes After Sales Service 26 ...

Страница 27: ...rmance Extraction power according to EN 61591 Extraction system C 150 mm Level I 150 m3 h Level II 250 m3 h Level III 350 m3 h Intensive level 500 m3 h Extraction system C 125 mm Level I 130 m3 h Level II 230 m3 h Level III 330 m3 h Intensive level 450 m3 h Unrestricted 550 m3 h Recirculation with charcoal filter Level I 100 m3 h Level II 150 m3 h Level III 250 m3 h Intensive level 350 m3 h Option...

Страница 28: ...Alteration rights reserved 4209 M Nr 06 417 570 10 ...

Отзывы: