background image

Operating and installation instructions

Cooker hoods
DA 361,
DA 371

It is 

essential

 to read these

Gi

operating instructions before
installing or using the machine
to avoid the risk of accidents or
damage to the machine.

 M.-Nr. 05 609 700

Содержание DA 361

Страница 1: ...stallation instructions Cooker hoods DA 361 DA 371 It is essential to read these Gi operating instructions before installing or using the machine to avoid the risk of accidents or damage to the machine M Nr 05 609 700 ...

Страница 2: ...ase filter 12 Fitting replacing the active charcoal filter 14 Defective lighting 15 Appliance dimensions 16 Installation Fitting the non return flap 17 Exhaust connection 18 Building in 18 Preparation for extraction 18 Preparation for recirculation 19 Connection for recirculation mode 19 Fitting the joystick 20 Joystick extension 20 Electrical connection 21 Connection for air extraction 22 Condens...

Страница 3: ...ren Danger of suffocation Rather than just throwing these materials away please ensure they are offered for recycling Disposal of your old appliance Old appliances may contain material which can be reclaimed or recycled Please contact your dealer your local waste collection centre or scrap mer chant about potential recycling schemes Ensure that the appliance presents no danger to children while be...

Страница 4: ...ust correspond in order to avoid risk of damage to the appliance Consult a qualified electrician if in doubt The electrical safety of this ap pliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system which complies with local and national regulations It is most import ant that this basic safety requirement is tested by a qualified electrician...

Страница 5: ...e are always covered by a pan Otherwise flames could be drawn up by the suction of the cooker hood parts of which could then be damaged Always switch the cooker hood on when using the hob otherwise con densation may collect in the hood which could cause corrosion When cooking with oil or fat chip pans and deep fat fryers etc do not leave the pans unattended Never leave an open grill unattended whe...

Страница 6: ...ce is fitted be neath the cooker hood and they have different minimum safety distances to the cooker hood select the greater distance Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves All ducting pipework and fittings must be of non flammable ma terial These can be obtained from the Miele Spare Parts department or from builders merchants The appliance must not be con ...

Страница 7: ...ractor can only be switched on when the heating ap pliance is switched off or vice versa N B The overall ventilation condition of the dwelling must be taken into ac count If in any doubt the advice of a competent builder or for gas a Corgi installer must be sought If the cooker hood is operated in recir culation mode with active charcoal filter then the above restrictions do not apply Appliances w...

Страница 8: ... is switched on the non return flap opens for the cooking smells to be blown directly outside Air recirculation with air recirculation conversion kit as an accessory The air is drawn in and cleaned first by grease filters and then cleaned by ac tive charcoal filters The cleaned air is then recirculated back into the kitchen through vents in the top of the ap pliance Before using the cooker hood fo...

Страница 9: ...escription of the appliance b Joystick This is used to operate the fan settings and the lighting c Hob lighting d Main switch e Grease filter f Fan setting indicator lamps Description of the appliance 9 ...

Страница 10: ...ator will light up To select a power level Press the joystick repeatedly to the right to select a higher power level and to the left to select a lower power level The relevant fan setting indicator will light up Depending on the intensity of cooking vapours levels I to III green indica tor lamps are usually sufficient for nor mal cooking When frying or cooking food with a strong aroma you may wish...

Страница 11: ...Hob lighting The hob lighting can be switched on and off independently of the fan Press the joystick once to the rear to switch it on and back to the front to switch it off Operation 11 ...

Страница 12: ...ashing up liquid applied with a well wrung out soft sponge or cloth Wipe dry using a soft cloth Avoid cleaning agents containing soda acids or chlorides abrasive cleaning agents e g pow der cleaners or cream cleaners and abrasive sponges e g pot scourers or sponges which have been pre viously used with abrasive cleaning agents These will damage the sur face material Grease filter The re usable met...

Страница 13: ...gents may cause the surface of the metal grease filter to discolour However this will not affect the func tioning of the grease filter in any way After cleaning leave the filter to dry for a while on an absorbent surface before putting it back in place When removing the filter for clean ing also clean off any residues of oil or fat from the now accessible hous ing to prevent the risk of these catc...

Страница 14: ...Miele Spare Parts Department Refer to the section Technical data for type and reference number Before fitting or replacing the active charcoal filters the grease filter must first be taken out see previous sec tion for instructions on how to do this Unwrap the active charcoal filters Secure the active charcoal filters using the screws enclosed Replace the grease filter Replace the active charcoal ...

Страница 15: ... screw out fuse is removed in countries where this is applicable Unscrew the fixing screws on the glass cover retainers When doing this push the glass cover upwards so that it does not fall on the hob surface Lower the glass cover to remove it Push the light tube to the left to disengage it and then carefully pull it down out of its holder Change the compact light tube 18 W or the starter Clip the...

Страница 16: ...Appliance dimensions Cut out dimensions Appliance dimensions 16 ...

Страница 17: ...bove an open grill from our range See Warning and Safety instruc tions for further information A distance of 650 mm above electric cookers hobs may be preferable to give more working space Fitting the non return flap Air extraction mode only If a non return flap is not present in the venting system the non return flap supplied must be fitted into the exhaust connection in the motor unit The flaps ...

Страница 18: ...st bars or is land areas Check prior to installation that the top of the appliance will be accessible after installation If this is not the case install the ex haust ducting and prepare the electri cal connection before installation Place the appliance in the cut out from below and align it Secure the cooker hood by the frame using 3 5 x 16 mm screws Preparation for extraction Secure the vent duct...

Страница 19: ... cal data Connection for recirculation mode When fitting the cooker hood in a wall unit the recirculation grille c has to be fitted in the top of the unit The exhaust connection b and the exhaust grille c are joined together using a suitable hose or flexible duct ing d If the front of the unit is ceiling height i e extractor canopies ceiling mounted units then an appropriate cut out must be made i...

Страница 20: ... with a 3 mm allen key Whilst doing so counter hold the base of the joystick with an SW 9 spanner Joystick extension The joystick can be extended if required Whilst counterholding the base of the joystick with an SW 9 spanner secure the joystick extension to the stub using a spring washer in be tween them as shown Then attach the lower section of the joystick as previously described turn the m sym...

Страница 21: ...e Before connecting the appliance read the safety notes in Warning and Safety Instructions and in the Electrical connection section Before using the appliance for the first time take the grease filter out and remove the protective foil from the filter frame Then replace the grease filter Installation 21 ...

Страница 22: ... level of the cooker hood would increase and extraction would be less effi cient Only reduce the diameter of the duct ing if absolutely necessary e g where narrower ducting has already been installed Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable ma terials for extraction connection Where ducting i...

Страница 23: ...be addressed The exhaust ducting will need to be suitably insu lated Condensate trap In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection Connection for air ext...

Страница 24: ...in stallation depending on country an ad ditional means of disconnection must be provided for all poles For extra safety it is advisable to install a residual current device RCD with a trip current of 30 mA in accordance with DIN VDE 0664 VDE 0100 Section 739 Do not connect via an extension lead Important UK If the appliance is fitted with a non re wireable plug BS 1363 UK and the socket outlets a...

Страница 25: ...een and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth sym bol z or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or col oured black For U K IRL ZA The wire which is coloured brown must be connected to the terminal which is marked with the letter L or col...

Страница 26: ...Department see back cover for address When contacting the Service Depart ment please quote the model and ser ial number of your appliance These are shown on the data plate which is visible when the grease filters are removed Please note that telephone calls may be monitored and recorded to improve our service After Sales Service 26 ...

Страница 27: ...mm Level I 220 m3 h Level II 350 m3 h Level III 450 m3 h Intensive level 560 m3 h Extraction system ø 100 mm Level I 200 m3 h Level II 330 m3 h Level III 380 m3 h Intensive level 440 m3 h Unrestricted 650 m3 h Recirculation with charcoal filters Level I 160 m3 h Level II 240 m3 h Level III 300 m3 h Intensive level 360 m3 h Depending on installation Charcoal filters Miele Active charcoal filter DKF...

Страница 28: ...Alteration rights reserved 44 002 GB IRL 2601 This paper consists of cellulose which has been bleached without the use of chlorine ...