Installation
*INSTALLATION*
42
a
The vent connection can also be connected at the back or to the left-hand side.
b
222 x 89 mm flat ducting can be used as an alternative for vent connection to
the rear or to the side.
c
The cooker hood is fastened in the cut-out using clamps. A solid installation
surface, e.g. made of wood, is required. Make sure that the structure can
support the load. Around the clamps, components such as supports and
ducting must be at least 25 mm from the cut-out.
d
Additional fixing points on the installation surface.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See “Warning and Safety” instructions for further information.
Cooking appliance
Minimum distance S
Electric hob
450 mm
Electric grill, deep fat fryer (electric)
650 mm
Multi-burner gas hob,
total output
≤
12.6 kW, no burner
>
4.5 kW
650 mm
Multi-burner gas hob,
total output
>
12.6 kW and
≤
21.6 kW,
no burner
>
4.8 kW.
760 mm
Multi-burner gas hob,
total output
>
21.6 kW,
or multi-burner gas hob where one burner
>
4.8 kW.
Not possible
Single burner gas hob, output
≤
6 kW.
650 mm
Single burner gas hob, output
>
6 kW and
≤
8.1 kW.
760 mm
Single burner gas hob, output
>
8.1 kW
Not possible