manualshive.com logo in svg
background image

Operating and installation instructions

Cooker hoods
DA 3160
DA 3180
DA 3190
DA 3160 EXT
DA 3190 EXT

To avoid the risk of accidents
or damage to this appliance
it is

essential

to read these

instructions before it is installed
and used for the first time.

M.-Nr. 07 777 490

en - GB

Содержание DA 2250 EXT

Страница 1: ...ns Cooker hoods DA 3160 DA 3180 DA 3190 DA 3160 EXT DA 3190 EXT To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time M Nr 07 777 490 en GB ...

Страница 2: ...n the wall housing unit 25 Attaching the lightshield 28 Weight of a lightshield matching existing furniture 28 Aligning the deflector plate 29 Fitting the grease filter 29 Setting up for extraction mode 30 Setting up for recirculation mode 31 Electrical connection 31 Connection for air extraction 32 Condensate trap 33 Silencer 34 Electrical connection 35 Operation with DSM 400 control module 36 Co...

Страница 3: ...pliance Electrical and electronic appliances often contain materials which if handled or disposed of incorrectly could be potentially hazardous to human health and to the environment They are however essential for the correct functioning of your appliance Please do not therefore dispose of it with your household waste Please dispose of it at your local community waste collection recycling centre o...

Страница 4: ...could be dangerous Miele cannot be held liable for damage resulting from incorrect or improper use or operation of the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they are supervised whilst using it or have been shown how to use it correctly by a person responsible for ...

Страница 5: ...e may only be used when it has been fully installed Only open the housing as described in the instructions given in the installation sheet and in the Cleaning and care section of this booklet Under no circumstances should any other parts of the housing be opened Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operational faults...

Страница 6: ...at the same time as other heating appliances that depend on the air from the room Warning danger of toxic fumes Great care should be taken when using the cooker hood at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room Such appliances include gas oil wood or coal fired boilers and heaters continuous flow or other water heaters...

Страница 7: ... the only way of ensuring adequate ventilation is via an open window a window contact switch should be fitted to ensure that the cooker hood can only operate when the window is opened sufficiently A window contact switch kit is available from good builders merchants Take care when ventilating the room through an open window that ventilation is not impaired by a closed blind or curtain The cooker h...

Страница 8: ...rwise condensation may collect in the hood which could cause corrosion When cooking with oil or fat chip pans and deep fat fryers etc do not leave the pans unattended Never leave an open grill unattended when grilling Overheated oil and fat can ignite and could set the cooker hood on fire Do not use the cooker hood without the filters in place This way you will avoid the risk of grease and dirt ge...

Страница 9: ...ld onto the cooker hood Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves All ducting pipework and fittings must be of non flammable material These can be obtained from the Miele Spare Parts department or from builders merchants The appliance must not be connected to a chimney or vent flue which is in use Neither should it be connected to ducting which ventilates room...

Страница 10: ...Guide to the appliance 10 ...

Страница 11: ... mode g Drop down lightshield to conceal control panel The front of the deflector plate can be fitted with a lightshield to match your kitchen furniture The DA 3160 and DA 3190 can be fitted with a DFB 61 or DFB 91 lightshield available as an optional accessory h On Off control for the fan i Controls to select fan power level j Lighting control Guide to the appliance 11 ...

Страница 12: ...ion air recirculation conversion kit required The air is drawn in and cleaned first by the grease filter and then by a charcoal filter The cleaned air is then recirculated back into the kitchen Charcoal filters are available to order through your Dealer or the Miele Spare Parts Department or via the internet on www miele shop com See back cover for contact details and Technical Data for model numb...

Страница 13: ...re usually sufficient for normal cooking For short periods of cooking food with intensive vapours and a strong aroma e g when searing meat you may wish to select the Intensive Setting IV Pull the deflector plate right out to achieve optimum extraction and to prevent unnecessary noise levels To switch the fan off Push the deflector plate back in The next time the deflector plate is pulled out the c...

Страница 14: ... control then the touch control and the hob lighting touch control again The indicator lamps for fan power levels I and IV will flash if the automatic switch off of the Intensive setting is not activated Press the touch control to activate automatic switch off The indicator lamps for fan power levels I and IV will now light up constantly Press the touch control to deactivate the automatic switch o...

Страница 15: ...washing up liquid applied with a well wrung out soft sponge or cloth Wipe the surfaces dry using a soft cloth Do not use too much water when cleaning the controls Water could penetrate into the electronics and cause damage Do not use cleaning agents containing soda acids chlorides or solvents abrasive cleaning agents e g powder cleaners or cream cleaners and abrasive sponges as well as pot scourer...

Страница 16: ...otes on cleaning earlier in this section Do not use stainless steel cleaners cleaning agents containing descaling agents dishwasher detergent oven sprays Grease filter The re usable metal grease filter in the appliance removes solid particles from the kitchen vapours grease dust etc preventing soiling of the cooker hood To avoid a build up of fat it should be cleaned every 3 4 weeks on average but...

Страница 17: ... dishwasher detergent Depending on the cleaning agent used cleaning the filters in a dishwasher can cause permanent discolouration to the surface However this will not affect the functioning of the filters in any way After cleaning leave the filter to dry for a while on an absorbent surface before putting it back in place When removing the filter for cleaning also clean off any residues of oil or ...

Страница 18: ...nt charcoal filters can be obtained from your Dealer Chartered Agent or the Miele Spare Parts department or via the internet on www miele shop com See back cover for contact details and Technical data for type and reference number Follow the instructions supplied with the charcoal filter when fitting it Replace the charcoal filter at least every six months or more frequently if necessary Used char...

Страница 19: ... the manufacturer s instructions Remove the charcoal filter if the cooker hood is being used in recirculation mode Before any cleaning or maintenance work disconnect the cooker hood from the mains supply Push down the lighting unit slightly via the opening in the safety panel The halogen lamp is now accessible to be unscrewed anti clockwise Replace it with a new halogen lamp specification GU GZ 10...

Страница 20: ... wall in the wall unit must be removable 3 In extraction mode when measuring for the height of the wall housing unit and the cut out account must be taken of any accessories fitted e g silencer DSM module 4 Recirculation mode with conversion kit DUU 151 5 Accessory DSM 400 Installation is also possible in a 600 mm wide unit Appliance dimensions 20 ...

Страница 21: ...of your cooking appliance 450 mm above electric hobs and cookers 650 mm above an open grill or deep fat fryer 650 mm above gas hobs and cookers If this cooker hood is installed above a Miele Wok CS 1028 CombiSet appliance a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the cooker hood See Warning and Safety instructions for further information Applia...

Страница 22: ...Installation accessories Installation 22 ...

Страница 23: ...nd flexible aluminium hose with clips this is not included but is available as an optional extra see Technical Data g DML 300 installation kit optional accessory contains hinging and screws for fixing a lightshield to match kitchen furniture lightshield not supplied with cooker hood 14 screws 3 5 x 16 mm for securing the cooker hood into the wall unit 8 screws M4 x 12 mm for securing the cooker ho...

Страница 24: ...Installation 24 ...

Страница 25: ... is further forward or back measurement T will need to be adjusted accordingly When installing an interim shelf or partition wall the building in space at the back must not be less than 180 mm If it is less than 180 mm position the appliance further back and reduce measurement T accordingly The building in position can be rectified later by adjusting the depth Cut the spacer strip supplied to meas...

Страница 26: ...kets are designed for 16 and 19 mm thick carcase sides Orientate the bracket so that the vertical depth matches the thickness of the panel as shown Place the appliance on its back Do not remove the protective film between the deflector plate and the casing until the hood has been placed in the housing unit Hold the grease filter firmly and pull it out with the deflector plate as shown Remove the g...

Страница 27: ...kets Note for dismantling the cooker hood Undoing the screws on the left and right inside the housing releases the brackets allowing the appliance to be removed from the unit Push the cooker hood back against the spacer strip Pull out the deflector plate Secure the appliance to the brackets using two screws on each side Remove the protective film between the deflector plate and the casing Installa...

Страница 28: ... behind using 4 plastic rivets as shown Attaching the lightshield Attach the lightshield if using A DML 300 installation kit available as an optional accessory is required for this This installation kit is supplied with the DFB lightshield Follow the installation instructions supplied Weight of a lightshield matching existing furniture The lightshield must not exceed 1300 g in weight This applies ...

Страница 29: ...grease filter Remove the protective strip around the edge of the grease filter Fit the grease filter To do this pull the deflector plate out Turn the grease filter so that the red plastic guides are at the front and facing upwards Fit the grease filter in the front of the deflector plate press it upwards and push it in together with the deflector plate It will slide onto the fixing pins at the bac...

Страница 30: ...g secure the exhaust connection supplied to exhaust ducting with hose clips If using C 125 mm ducting fit the reducing collar into the exhaust connection and secure the exhaust ducting to the reducing collar with a hose clip See Connection for air extraction Place the exhaust ducting on the fan connection for the cooker hood See Connection for air extraction for further instructions on fitting the...

Страница 31: ...the kit Make sure that the slats in the exhaust grille point towards the centre of the room and not towards a wall or the ceiling A non return flap is not used in recirculation mode Fit the charcoal filter see Cleaning and care Electrical connection Refer to the notes in Electrical connection and Warning and Safety instructions before connecting to the electricity supply For appliances connected t...

Страница 32: ...can result in the exhaust ducting distorting To achieve the greatest possible air extraction with the lowest noise level please note the following To ensure efficient air extraction the diameter of the exhaust ducting should not be less than 150 mm If flat ducting is being used the cross section must not be smaller than the cross section of the exhaust connection All ducting pipework and fittings ...

Страница 33: ...l need to be addressed The exhaust ducting will need to be suitably insulated Condensate trap optional accessory In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur Condensate traps are available for C 125 mm or C 150 mm ducting When installing a condensate trap ensure that it is positi...

Страница 34: ...ed between the fan and the exhaust grille b The space needs to be checked in some cases air extraction with external fan To minimise noise from the fan in the kitchen the silencer should be positioned in front of the external fan c if possible or if the ducting is long then in the ducting inside the cooker hood itself d In the case of an external fan placed inside the house fitting a silencer behi...

Страница 35: ...ppliance should be made via a suitable isolator or a double pole fused spur connection unit which complies with national and local safety regulations and the On Off switch should be easily accessible after the appliance has been built in When switched off there must be an all pole contact gap of 3 mm in the switch including switch fuses and relays according to EN 60335 If the switch is not accessi...

Страница 36: ...switch must be tested for safety after it has been connected If the control module is disconnected in order to operate the cooker hood without the window contact switch e g after moving house the cooker hood electronics must be reset by a Miele service technician Potential free connection This enables a further appliance to be controlled by the switch setting on the cooker hood fan For instance it...

Страница 37: ...n the cooker hood lighting via a light switch in the house Installation The control module must be installed above the cooker hood housing The control module is supplied with its own detailed operating and installation instructions Operation with DSM 400 control module 37 ...

Страница 38: ...ing your Dealer or Miele please quote the model and serial number of your appliance These are shown on the data plate which is visible when the grease filter is removed For G B Please note that telephone calls may be monitored and recorded for training purposes N B A call out charge will be applied for service visits where the problem could have been resolved as described in these instructions Aft...

Страница 39: ...ø 150 mm Level I 150 m3 h Level II 275 m3 h Level III 400 m3 h Intensive Setting 550 m3 h Recirculation with charcoal filter Level I 80 m3 h Level II 180 m3 h Level III 280 m3 h Intensive Setting 350 m3 h Optional accessories for recirculation mode Conversion Kit DUU 151 Miele charcoal filter DKF 13 1 For EXT models the connected load and extraction power will depend on the type of external motor ...

Страница 40: ...Alteration rights reserved 1111 M Nr 07 777 490 02 ...

Отзывы: