Страница 1: ... installation instructions Cooker hood To prevent the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time en GB M Nr 10 572 930 ...

Страница 2: ... filters 20 Charcoal filter 22 Disposing of charcoal filters 22 Changing a lamp 23 After Sales Warranty 24 Position of the data plate 24 Installation 25 Before installation 25 Assembly parts 26 Appliance dimensions 28 Safety distance between hob and cooker hood S 29 Installation recommendations 30 Protective foil 30 Deflector 30 Installation under a wall unit 32 Wall installation 34 For air extrac...

Страница 3: ...Contents 3 Electrical connection 38 Connection for air extraction 39 Condensate trap 40 Silencer 40 Technical data 41 ...

Страница 4: ...s in a safe place and ensure that all users are familiar with the contents Pass them on to any future owner of the appliance Correct application This cooker hood is intended for use in domestic households and similar working and residential environments The cooker hood is not intended for outdoor use It must only be used as a domestic appliance to extract vapours and remove odours from cooking Any...

Страница 5: ...ars and older may only use the cooker hood unsupervised if they have been shown how to use it safely and recognise and understand the consequences of incorrect operation Children must not be allowed to clean or maintain the cooker hood unsupervised Please supervise children in the vicinity of the cooker hood and do not let them play with it The hob lighting is very intensive Ensure in particular t...

Страница 6: ... met If in any doubt please have the electrical installation tested by a qualified electrician Reliable and safe operation of this cooker hood can only be assured if it has been connected to the mains electricity supply The connection data voltage and frequency on the data plate of the cooker hood must match the mains electricity supply in order to avoid the risk of damage to the cooker hood Compa...

Страница 7: ...care section of this booklet Under no circumstances should any other parts of the housing be opened The manufacturer s warranty will be invalidated if the appliance is not repaired by a Miele approved service technician Miele can only guarantee the safety of the appliance when genuine original Miele replacement parts are used Faulty components must only be replaced by Miele spare parts If the elec...

Страница 8: ... the open air through a chimney or extraction ducting They include gas oil wood and coal fired boilers and heaters continuous flow or other water heaters gas hobs and ovens The cooker hood draws in air from the kitchen and from neighbouring rooms This applies to the following modes of operation extraction mode recirculation mode with a recirculation box installed outside the room If there is insuf...

Страница 9: ...ch cannot be blocked e g in windows doors and outside wall vents The cross section of the inlet openings must enable sufficient ventilation A ventilation brick alone is not generally sufficient to ensure safe ventilation The overall ventilation condition of the dwelling must be taken into account If in any doubt the advice of a competent builder or for gas a qualified gas fitter should be sought I...

Страница 10: ...overed by a pan Switch the cooking zone off when a pan is removed even for a short time Select a pan which is suitable for the size of the burner Regulate the flame so that it does not burn up the sides of the pan Avoid overheating the pan e g when cooking with a wok Always switch the cooker hood on when a cooking zone is in use otherwise condensation may collect in the hood which could cause corr...

Страница 11: ...r hood may be operated above the cooker hob Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves An insufficient safety distance between the hob and the cooker hood can result in damage to the cooker hood The minimum safety distances between the top of the cooker or hob and the bottom of the cooker hood given in the Installation section of this booklet must be maintained...

Страница 12: ...d into a chimney or ventilation duct no longer used for other purposes seek professional advice Cleaning and care There is a risk of fire if the cooker hood is not cleaned as described in these operating instructions Do not use a steam cleaning appliance to clean this appliance The steam could reach electrical components and cause a short circuit Accessories Only use genuine original Miele accesso...

Страница 13: ...lso contain specific materials compounds and components which were essential for their correct function and safety These could be hazardous to human health and to the environment if disposed of with your domestic waste or if handled incorrectly Please do not therefore dispose of your old appliance with your household waste Please dispose of it at your local community waste collection recycling cen...

Страница 14: ...Guide to the appliance 14 ...

Страница 15: ...sory required for recirculation mode d Cover for the charcoal filter compartment e Grease filters f Exhaust socket 150 mm or 125 mm with reducing collar g Non return flap h Exhaust outlet i Recirculation grille j Sliding switch for the hob lighting k Sliding switch for the fan ...

Страница 16: ... the cooker hood is switched off When the cooker hood is switched on the non return flap opens for the cooking vapours to be blown directly outside If the on site ventilation system does not have a non return flap the non return flap supplied must be fitted in the exhaust socket in the motor unit Recirculation mode recirculation mode cooker hoods require a conversion kit and charcoal filter see Te...

Страница 17: ...ting B Switch the fan on with the fan switch and select the power level you want Switching the fan off It is advisable to run the fan for a few minutes after cooking has finished to neutralise any lingering vapours and odours in the air Turn the fan switch to 0 Switching the hob lighting on off The hob lighting can be switched on and off independently of the fan Use the lighting switch to switch t...

Страница 18: ...d power level and therefore benefit from reduced energy consumption Check the power level selected on the cooker hood A lower power level is generally sufficient for the majority of cooking Only use the Booster setting when necessary When a large volume of cooking vapours is being produced switch to a high power level in good time This is more efficient than operating the cooker hood for longer to...

Страница 19: ...ds chlorides or solvents abrasive cleaning agents e g powder cleaners or cream cleaners and abrasive sponges as well as pot scourers or sponges which have been used previously with abrasive cleaning agents Important for appliances with stainless steel surfaces This information does not apply to the controls Stainless steel surfaces can be cleaned with a proprietary non abrasive cleaning agent desi...

Страница 20: ...ervals Heavily soiled grease filters hinder air extraction and will lead to increased levels of soiling in the cooker hood and in the kitchen Cleaning interval Accumulated grease solidifies over a longer period of time and makes cleaning more difficult The grease filters should therefore be cleaned every 3 to 4 weeks Removing a grease filter When handling a grease filter be careful not to drop it ...

Страница 21: ...shwasher programme with a wash temperature between 50 C and 65 C Depending on the detergent used cleaning the filters in a dishwasher may cause the inside filter surfaces to become discoloured This will not affect the functioning of the grease filters in any way After cleaning After cleaning leave the filters to dry on an absorbent surface before replacing them When removing the filters for cleani...

Страница 22: ...replacing a charcoal filter the grease filters must first be taken out see previous section for instructions on how to do this Push the cover for the charcoal filter compartment slightly to the right and then lower it to remove it Take the charcoal filter out of its packaging Insert the charcoal filter in its compartment and push it up against the recirculation grille Refit the cover and the greas...

Страница 23: ...e from Miele or from specialist retailers Switch off the fan and the lighting Remove the grease filters Disconnect the cooker hood from the mains electrical supply see Warning and Safety instructions The lamps can get hot in use Allow the lamps to cool down for a few minutes before changing them Loosen the halogen lamp s securing screw a little Slide the screw and the lamp downwards Then tighten t...

Страница 24: ...del and serial number of your appliance These are shown on the data plate Position of the data plate The data plate is visible after removing the grease filter Warranty U K In the U K the appliance warranty is valid for 2 years from the date of purchase However you must activate your cover by calling 0330 160 6640 or registering online at www miele co uk Please note that telephone calls may be mon...

Страница 25: ...nstallation 25 Before installation Before installation it is important to read the information given on the following pages as well as the Warning and Safety instructions at the beginning of this booklet ...

Страница 26: ...Installation 26 Assembly parts ...

Страница 27: ...exhaust opening when using recirculation mode The foil is included with the charcoal filter optional accessory 4 screws 5 x 60 mm and 4 plugs 8 x 50 mm for securing to the wall The screws and plugs are designed for use in solid walls only For other types of wall construction alternative fixings will be required Make sure the wall is able to take the weight of the cooker hood 4 self tapping screws ...

Страница 28: ...th reducing collar a If the cooker hood is replacing another cooker hood which had a construction height of 150 mm a filler panel can be used to cover the aperture left by the previous cooker hood The filler panel can be ordered as an accessory in various widths Miele DAB 55 for DA 1255 Miele DAB 60 for DA 1260 Miele DAB 100 for DA 1200 ...

Страница 29: ...afety instructions for further information Cooking appliance Minimum distance S Electric hob 450 mm Electric grill deep fat fryer electric 650 mm Multi burner gas hob total output 12 6 kW no burner 4 5 kW 650 mm Multi burner gas hob total output 12 6 kW and 21 6 kW no burner 4 8 kW 760 mm Multi burner gas hob total output 21 6 kW or multi burner gas hob where one burner 4 8 kW Not possible Single ...

Страница 30: ...ilings or features in the vicinity of the cooker hood Protective foil The housing components of stainless steel models have protective foil around them to protect them from transport damage Please remove the grease filters from the appliance and remove this foil from the housing components and the frames of the grease filters before installing the cooker hood The foil can be peeled off easily Defl...

Страница 31: ...it as appropriate for the operating mode required To do this press the two hooks remove the deflector turn it and push it back in until it clicks into position For operation in recirculation mode cover the opening at the back of the cooker hood with the protective foil supplied with the charcoal filter optional accessory ...

Страница 32: ...raction mode make a cut out of at least 170 mm in the bottom of the unit If the mains connection cable is to be fed through the unit a hole will also need to be made in the unit for it Securing from above Use only the fixing points as shown on the drilling template and the screws supplied Incorrect fitting can lead to damage to the cooker hood and could compromise electrical safety e g electric sh...

Страница 33: ... as described above Should it not be possible to do so the cooker hood can also be secured from below to the base of the unit The screws supplied are intended for securing the cooker hood to a solid wooden cabinet floor with a minimum thickness of 16 mm Ensure the floor can permanently support the weight of the appliance Lift the cooker hood underneath the wall unit Insert the wood screws supplied...

Страница 34: ...allation You also have the option of securing the cooker hood to the wall using two fixing brackets Cut the drilling template to size and position against the wall The top edge of the template indicates the top edge of the cooker hood Please observe the safety distance S to the hob see Appliance dimensions Mark and drill four holes for the fixing brackets 8 mm Remove the drilling template ...

Страница 35: ...id walls only For other types of wall construction alternative fixings will be required Make sure the wall is able to take the weight of the cooker hood Remove the lamps Loosen the halogen lamp s securing screw a little Slide the screw and the lamp downwards Then tighten the screw again Turn the halogen lamp anti clockwise and pull it out ...

Страница 36: ... hood to prevent it being lifted off the fixing brackets Replace the lamps Replace the grease filters For air extraction mode For 150 mm exhaust ducting cut the exhaust socket to size with a sharp knife For 125 mm exhaust ducting the exhaust socket is installed as it is Insert the non return flap if required Make sure that it opens easily and closes again by itself ...

Страница 37: ...lter see Cleaning and care Electrical connection Refer to the notes in Electrical connection and Warning and Safety instructions before connecting to the electricity supply Connect the cooker hood to the electricity supply Functional check To do this switch the fan on In air extraction mode air should not come out of the recirculation grille at the front of the cooker hood In recirculation mode th...

Страница 38: ...pply Connection of this appliance should be made via a suitable isolator or a double pole fused spur connection unit which complies with national and local safety regulations and the On Off switch should be easily accessible after the appliance has been built in When switched off there must be an all pole contact gap of 3 mm in the switch including switch fuses and relays according to EN 60335 If ...

Страница 39: ... of the exhaust connection The exhaust ducting should be as short and straight as possible Only use wide radius bends The exhaust duct must not be kinked or compressed Ensure that all connections are strong and airtight Remember that any constriction of the air flow will reduce extraction performance and increase operating noise If the exhaust is ducted through an outside wall a telescopic wall ve...

Страница 40: ...densate trap ensure that it is positioned vertically and as closely as possible above the exhaust socket The arrow on the housing indicates the direction of air flow Silencer To achieve even further reductions in noise levels a special silencer optional accessory can be fitted in the ducting system Extraction mode The silencer not only reduces noise from the motor outside the house but also sounds...

Страница 41: ...ting 2 x 3 W Total connected load 236 W Voltage frequency AC 230 V 50 Hz Fuse rating 5 A Mains connection cable length 1 5 m Weight DA 1255 11 kg DA 1260 11 2 kg DA 1200 14 6 kg Accessories required for recirculation mode 1 charcoal Filter DKF 18 1 ...

Страница 42: ... A most efficient to G least efficient A Airflow at best efficiency point 317 1 m 3 h Air flow min speed 275 m 3 h Air flow max speed 355 m 3 h Air flow intensive or boost setting 545 m 3 h Max air flow Qmax 545 m 3 h Air pressure at best efficiency point 313 Pa Airborne acoustical A weighted sound power emissions min speed 57 dB Airborne acoustical A weighted sound power emissions max speed 64 dB...

Страница 43: ... A most efficient to G least efficient A Airflow at best efficiency point 326 8 m 3 h Air flow min speed 275 m 3 h Air flow max speed 355 m 3 h Air flow intensive or boost setting 545 m 3 h Max air flow Qmax 545 m 3 h Air pressure at best efficiency point 313 Pa Airborne acoustical A weighted sound power emissions min speed 57 dB Airborne acoustical A weighted sound power emissions max speed 64 dB...

Страница 44: ......

Страница 45: ......

Страница 46: ......

Страница 47: ...ara Sapura Kencana Petroleum Solaris Dutamas No 1 Jalan Dutamas 1 50480 Kuala Lumpur Malaysia Phone 603 6209 0288 Fax 603 6205 3768 Miele New Zealand Limited IRD 98 463 631 Level 2 10 College Hill Freemans Bay Auckland 1011 New Zealand Tel 0800 464 353 Internet www miele co nz New Zealand Miele Pte Ltd 163 Penang Road 04 03 Winsland House II Singapore 238463 Tel 65 6735 1191 Fax 65 6735 1161 E Mai...

Страница 48: ...M Nr 10 572 930 03 en GB DA 1255 DA 1260 DA 1200 ...