Technical Information
CVA4070 / CVA4075 Coffee Systems
Figure 5-22:
CVA4070 Solenoid Removal
3. Pull out the safety springs at the connection of the hot water solenoid
(Figure 5-22).
4. Take the solenoid out.
5. Pull the connecting plug off the solenoid.
Warning!
To prevent malfunctions in the water system (for example clogging of the
valves), never use grease, oil or other lubricants when assembling the
water supplying components.
63