Midland LXT560 Скачать руководство пользователя страница 1

LABORATORY TESTING PROCEDURES 

LXT560 

Page 1 

UNIT TEST - (UNIT ASSEMBLED) 

 

TEST PREPARATION 

 

1) Install 4 AAA Alkaline batteries (observe polarity markings). 
2) Turn on unit by pressing the power button. 

 

SYSTEM TEST 

 

1) Radiated Transmit and Receive performance may be observed. 
2) Audio out & Audio in are available at the Headset jack. 

 

LABORATORY TEST - (UNIT UN-ASSEMBLED) 

 

TEST PREPARATION 

 

1) Disassemble unit (4 screws – 2 behind batteries). Remove the PCB from the cabinet. 
2) Remove the antenna with soldering iron and install a 50 ohm coax cable in its place. 
3)  Either  clip  alligator  leads  or  solder  test  leads  to  the  power  supply  connections.  The 

negative  terminal  is  the  lower  right  PCB  area.  The  positive  terminal  is  the  lower  left 
PCB area. 

4) Connect 6VDC power source to the terminals, observing correct polarity. 
5) Connect an 12-ohm load through the Headset jack 
6) Connect a audio generator with 10uF coupling capacitor through the Headset jack 
7)  Select  desired  channel  1-36  using  CH  up/down  keypad  switch.  The  rubber  keypad 

may be removed from the front cabinet and used directly on the PCB. 

 
 
 

 