background image

 
 

 

 

 

 

 

                                                                        MIDEA 

60Hz 

    

 

                         

PORTABLE

 

PD SERIES 

                                                                                                                             

SINGLE-HOLE

 

 

 

 

 

Содержание PD series

Страница 1: ...MIDEA 60Hz PORTABLE PD SERIES SINGLE HOLE ...

Страница 2: ...n function 14 7 4 Fan only mode function requirement 14 7 5 Cooling mode function requirement 14 7 6 Drying mode 15 7 7 Heating mode heater 16 7 8 Heating mode heat pump 16 7 9 Sensor malfunction 17 7 10 Some standard functions synopsis 17 8 Installation details 19 8 1 Installation instructions 19 8 2 Care and maintenance 25 9 Basic test procedure 27 9 1 Defective compressor 27 9 2 Sealed refriger...

Страница 3: ...fire or electric shock Install the panel and the cover of control box securely There is risk of fire of electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fore or electric shock Use the correctly rated breaker of fuse There is risk of fire or electric shock Do not modify or extend the power cable There is risk of fire or electric shock Do not in...

Страница 4: ...er appliance near the power cable There is risk of fire and electric shock Do not allow water to run into electric parts It may cause fire failure of the product or electric shock Do not store or use flammable gas or combustible near the product There is risk of fire or failure of product Do not use the product in a tightly closed space for a long time Oxygen deficiency could occur When flammable ...

Страница 5: ...e to ensure that nobody could step on or fall onto the outdoor unit This could result in personal injury and product damage Caution Always check for gas refrigerant leakage after installation or repair of product Low refrigerant levels may cause failure of product Install the drain hose to ensure that water is drained away properly A bad connection may cause water leakage Keep level even when inst...

Страница 6: ...ly Clean the filter every two weeks or more often if necessary A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage Do not insert hands or other object through air inlet or outlet while the product is operated There are sharp and moving parts that could cause personal injury Do not drink the water drained from the product It is not sanitary cou...

Страница 7: ...appliance shall be stored so as to prevent mechanical damage from occurring A warning that the appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which ...

Страница 8: ...6 2 Model Lists ON OFF Capacity units 10K MPPDB 10CRN8 BCG8 10K MPPDB 10HRN8 BCG8 ...

Страница 9: ... Optional Washable filter Self diagnosis and auto protection function Anti freezing control in cooling or drying mode Prevent the water being freezed on evaporator by sensing the evaporator pipe temperature in cooling or drying mode Auto restart When the power supply is interrupted and then restore the air conditioners automatically restore the previous function setting Time Delay Safety Restartin...

Страница 10: ...settings 1 2 increments in a range of 17 62 to 30 88 or the TIMER setting in a range of 0 24hrs NOTE The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds 5 MODE select button Select the appropriate operating mode Each time you press the button a mode is select...

Страница 11: ...tom tray is full Connect the drain hose and drain the collected water away If protection repeats call for service NOTE When more than one codes occur the priority of the code display order is EC E4 E3 E2 E1 P1 9 FOLLOW ME TEMP SENSING feature optional NOTE This feature can be activated from the remote control ONLY The remote control serves as a remote thermostat allowing for the precise temperatur...

Страница 12: ...10 4 Dimension Unit Dimension W mm H mm D mm small body 454 700 365 big body 467 765 397 ...

Страница 13: ...tant components and their function in what is called the refrigeration system 1 This will help to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle LIQ U ID S ID E G AS S ID E E VA PO R A T OR C O N D EN SE R C O M P R ES S OR C AP ILIA R Y T U BE ...

Страница 14: ... E A T E X C H A N G E E V A P O R A T O R H E A T E X C H A N G E C O N D E N S E R C O M P R E S S O R C H E C K V A L V E H e a tin g M o d e l o n ly C A P IL IA R Y T U B E R E V E R S IN G V A L V E H e a tin g M o d e l o n ly C O O L IN G H E A T IN G A C C U M U L A T O R ...

Страница 15: ...13 6 Wiring Diagram MPPDB 10CRN8 BCG8 MPPDB 10HRN8 BCG8 ...

Страница 16: ...e function requirement 7 4 1 The compressor and outdoor fan are OFF in Fan only mode except P1 protection 7 4 2 The speed of indoor fan can be optionally chosen as High Mid Low 7 4 3 The TS can t be controlled and the LED displays as T1 7 4 4 The TIMER function is valid in the fan only mode 7 5 Cooling mode function requirement 7 5 1 The speed of indoor fan can be optionally selected as High Mid L...

Страница 17: ...s valid in cooling mode 7 6 Drying mode 7 6 1 The unit operates in drying mode If TA 13 outdoor fan turns on and then the compressor operates after 15 seconds later 7 6 1 1 When TA 13 the compressor stops working And the outdoor fan will stop delaying for 5 seconds until it operates for 3minutest 7 6 1 2 When TA 14 the outdoor fan operates and the compressor will restart to operate after 15seconds...

Страница 18: ...de heat pump 7 8 1 When TA TS 5 compressor operates When TA TS 6 compressor stops When TA 5 heat pump mode is invalid and water pump indoor motor outdoor motor compressor shaded pole motor stop When TA 6 heat pump mode resumes to be valid 7 8 2 At non defrosting situation shaded pole motor always stops Compressor operates Outdoor motor is on at high speed Then outdoor motor stops at a delay of 30s...

Страница 19: ...ction When the unit is on press the Timer button will initiate the Auto off stop program the TIMER OFF indicator light illuminates Press the UP or down button to select the desired time Press the TIMER button again within 5 seconds the Auto on start program is initiated And the TIMER ON indicator light illuminates Press the up or down button to select the desired Auto on start time When the unit i...

Страница 20: ...2 30 minutes The temperature will then increase cooling or decrease heating by another 1 2 after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally seting temperature This ends the Sleep mode and the unit will continue to operate as originally programmed ...

Страница 21: ...g enough to support the unit The unit has casters to aid placement but it should only be rolled on smooth flat surfaces Use caution when rolling on carpet surfaces Do not attempt to roll the unit over objects The unit must be placed within reach of a properly rated grounded socket Never place any obstacles around the air inlet or outlet of the unit Allow 30cm of space from the wall for efficient a...

Страница 22: ...assembly into the lower groove of the air outlet of the unit while the hook of the adaptor is aligned with the hole seat of the air outlet and slide down the Exhaust hose assembly along the arrow direction for installation Step 3 Preparing the Adjustable Window Slider 1 Depending on the size of your window adjust the size of the window slider 2 If the length of the window requires two window slide...

Страница 23: ...21 Note Once the Exhaust Hose assembly and Adjustable Window Slider are prepared choose from one of the following three installation methods Type 1 Hung Window Installation optional ...

Страница 24: ...22 Type 2 Sliding Window Installation optional ...

Страница 25: ...ose Assembly with Wall Exhaust Adaptor A to the Wall Exhaust Adaptor B Note To ensure proper function DO NOT overextend or bend the hose Make sure that there is no obstacle around the air outlet of the exhaust hose in the range of 500mm in order to the exhaust system works properly All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different ...

Страница 26: ...he back of the unit install the drain connector 5 8 universal female mender with 3 4 hose locally purchased For the models without drain connector just attach the drain hose to the hole Place the open end of the hose adaptor directly over the drain area in your basement floor Please refer to Fig 19 NOTE Make sure the hose is secure so there are no leaks Direct the hose toward the drain making sure...

Страница 27: ...m drain plug before using the unit 8 2 Care and maintenance Important 1 Be sure to unplug the unit before cleaning or servicing 2 Do not use gasoline thinner or other chemicals to clean the unit 3 Do not wash the unit directly under a tap or using a hose It may cause electrical danger 4 If the power cord is damaged it should be repaired by manufacture or its agency 1 Air filter Clean the air filte...

Страница 28: ...ime Remove the rubber plug at the back of the unit and attach a hose to drain outlet Place the open end of the hose directly over the drain area in your basement floor See below Fig 23 Remove the plug from the bottom drain outlet all the water in the bottom tray would drain out See below Fig 23 Keep the appliance running on FAN mode for half a day in a warm room to dry the appliance inside and pre...

Страница 29: ...ss the start and run terminal All compressors are internally spring mounted and externally mounted on rubber isolators 9 1 1 Compressor wiring test Remove compressor terminal box cover and disconnect wires from terminals Using an ohmmeter check continuity across the following Terminal C and S no continuity Open winding replace compressor Terminal C and R no continuity Open winding replace compress...

Страница 30: ... valve on the suction and discharge or liquid process tube 2 Attach gauges to the high and low sides of the system 3 Start the system and run a cooling or heating performance test If test shows A Below normal high side pressure B Above normal low side pressure C Low temperature difference across coil The compressor valves are faulty replace the compressor 9 1 4 Terminal overload external Some comp...

Страница 31: ... terminal Should the internal temperature and or current draw become excessive the contacts in the overload will open turning off the compressor The overload will automatically reset but may require several hours before the heat is dissipated 9 1 7 Checking the internal overload 1 No power to unit remove the leads from the compressor terminals 2 Using an ohmmeter test continuity between terminals ...

Страница 32: ...etc 1 Recover the refrigerant from the system at the process tube located on the high side of the system by installing a line tap on the process tube Apply gauge from process tube to EPA approved gauges from process tube to EPA approved recovery system Recover CFCs in system to at least 5 2 Cut the process tube below pinch off on the suction side of the compressor 3 Connect the line from the nitro...

Страница 33: ...compressor motor burnout 1 Recover all refrigerant and oil from the system 2 Remove compressor capillary tube and filter drier from the system 3 Flush evaporator condenser and all connecting tubing with dry nitrogen or equivalent to remove all contamination from system Inspect suction and discharge line for carbon deposits Remove and clean if necessary 4 Reassemble the system including new drier s...

Страница 34: ...r is serviceable 2 Disconnect fan motor wires from fan speed switch or system switch 3 Apply live test cord probes on black wire and common terminal of capacitor Motor should run at high speed 4 Apply live test cord probes on red wire and common terminal of capacitor Motor should run at low speed 5 Apply live test cord probes on each of the remaining wires from the speed switch or system switch to...

Страница 35: ...k to infinity 4 Reverse the leads of the probe and momentarily touch the capacitor terminals The deflection of the pointer should be two times that of the first check if the capacitor is good 5 Repeat steps 3 and 4 to check fan motor capacitor NOTE A shorted capacitor will indicate a low resistance and the pointer will move to the 0 end of the scale and remain there as long as the probes are conne...

Страница 36: ...0 52 3 1918 1 37 1988 26 9 5507 53 3 0707 0 35 2024 27 9 1245 54 2 959 1 33 3269 28 8 7198 55 2 8442 2 31 5635 29 8 3357 56 2 7382 3 29 9058 30 7 9708 57 2 6368 4 28 3459 31 7 6241 58 2 5397 5 26 8778 32 7 2946 59 2 4468 6 25 4954 33 6 9814 60 2 3577 7 24 1932 34 6 6835 61 2 2725 8 22 5662 35 6 4002 62 2 1907 9 21 8094 36 6 1306 63 2 1124 10 20 7184 37 5 8736 64 2 0373 11 19 6891 38 5 6296 65 1 96...

Страница 37: ...urn off the unit and clean the filter according to instructions Exhaust hose is not connected or is blocked Turn off the unit disconnect the hose check for blockage and reconnect the hose The unit is low on refrigerant Call a service technician to inspect the unit and top off refrigerant Temperature setting is too high Decrease the set temperature The windows and doors in the room are open Make su...