background image

WEEKLY SCHEDULE CONTROLLER 

OF AIR CONDITIONER 

Warning 

Caution

Warning

Usage  

 

Warning   

MODEL: MD-CCM04/E

                                                              Thank you very much for purchasing our product.
Before using your unit, please read this manual carefully and keep it for future reference.

OWNER’ S MANUAL

Содержание MD-CCM04/E

Страница 1: ... SCHEDULE CONTROLLER OF AIR CONDITIONER MODEL MD CCM04 E Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference OWNER S MANUAL ...

Страница 2: ......

Страница 3: ...cautions that should be brought to your attention during operation In order to ensure correct service of the wired controller please read this manual carefully before using the unit For convenience of future reference keep this manual after reading it ...

Страница 4: ...TORS ON THE CONTROLLER 5 INSTALLATION METHOD 6 NAME AND OPERATION OF THE BUTTON ON THE CONTROLLER 7 USING METHOD SET TIME SET DATE QUERY PLAN SET PLAN OTHERS 8 TECHNICAL INDICATION AND REQUIREMENT 9 TATBLE OF ALARM STATES 10 TABLE OF PROTECTION STATES PAGE 1 2 2 3 4 5 7 7 8 8 9 10 11 11 12 ...

Страница 5: ...proper handling may lead to personal death or severe injury Means improper handling may lead to personal injury or property loss Note 1 Harm means injury burn and electric shock which need long term treatment but need no hospitalization 2 Property loss means loss of properties and materials W Warning arning Caution Caution Icon description Meaning lcon It indicates forbidding The forbidden subject...

Страница 6: ...mmable aerosol to the wire controller directly Otherwise fire may occur Do not operate with wet hands or let water enter the wire controller Otherwise electric shock may occur 2 SUMMARIZE 3 FUNCTION SUMMARY Usage condition 1 Power supply 5V DC 2 Operation temperature 15 C 43 C 5 F 109 F 3 Operation humidity 40 90 RH Main function 1 Connecting to indoor unit by 5V GND E Y X terminal 2 Buttons setti...

Страница 7: ...ed indication There are four fan modes auto low middle high For some air conditioners with no middle fan then the middle fan is seen as high speed ĹFault indication ĺTemperature or error code indication ĻWeekly Schedule Controller switch indication ļDate indication ĽTime indication ľPeriod indication ĿLock indication ŀWeek indication 3 Operation mode Error Temperature or Error code Timer on off Da...

Страница 8: ... cores wire 2 cores wire INDOOR UNIT When a weekly schedule controller is needed a small 2 cores wire and 3 cores wire should be added Connect like the following figure 5V GND E Y X 5V GND To display board To main board Yellow Brown Black Red White E Y X ...

Страница 9: ...y model the heating mode should be skipped ĸFan speed button press this button then the operation fan will change in turn as follows Auto Low Middle High ĹEdit button press this button then you can setup Weekly time function Details in page 9 SET PLAN_ķ 5 6 NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROLLER 21 2 23 5 7 21 03 ...

Страница 10: ...ode state can not be canceled when weekly timer has come back to supply power after interruption of power supply ľCancel button It is for not saving and retreating or to cancel the temporary setting Details in page 10 ĿQuery button Press Query display present indoor temperature value press Cancel to back press Add or Reduce to select the day you want to query from Sun to Sat press Confirm Then pre...

Страница 11: ...rying the delay time you set ON OFF button Push the button at the condition of OFF the OPERATION lamp lights and the wire controller enters into ON operation simultaneously sends the information of operation mode fan speed temperature etc 7 7 USING METHOD set hour set minute set done REDUCE REDUCE TIME ADD CONFIRM CONFIRM ADD or or In operating Press the key CANCEL to turn back to the previous ste...

Страница 12: ...rating Press the key CANCEL to turn back to the previous step or the normal display interface NOTE QUERY PLAN select week select period REDUCE REDUCE QUERY ADD CONFIRM CONFIRM ADD or or display various parameters of the selected period CANCEL CONFIRM back to the normal display interface Under the normal display interface Under the normal display interface ...

Страница 13: ...st period is done set various parameters of the next period from the place till the setting of parameters of all the four period is done turn back to the slect week interface as this time you can also press the key CANCEL back to the normal display interface In operating Press the key CANCEL to turn back to the previous step or the normal display interface NOTE REDUCE ADD or Long time press the bu...

Страница 14: ...emperature you want And When you finish the setting press the Confirm button to send The air conditioner will start with the information you set What is the temporary setting ķ Weekly timer is operating When the unit operated with the Weekly timer Any operations of mode fan speed temperature are called temporary setting When the wire controller displays Currently icon temporary setting has been ef...

Страница 15: ...r overcurrent 4 times Air speed detection out of control EEPROM error Zero crossing detection error Malfunction in air discharge temperature sensor of T3 T4 or digital compressor T2B Sensor malfunction T2A Sensor malfunction T1 Sensor malfunction Communication malfunction Phases sequence error or default Weekly schedule Sensor malfunction When the unit appears error the corresponding error code wi...

Страница 16: ...mpressor overcurrent Power supply over under voltage protection Air exhaust low pressure protection Air exhaust high pressure protection Air exhaust temperature protection Compressor temperature protection Condensate high temperature protection Anti cool air or defrost protection Evaporator temperature protection ...

Страница 17: ......

Страница 18: ...202055100846 Version MDV12U 004AW ...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Отзывы: