background image

CASSETTE- TYPE AIR  CONDI TIONER

Owner’s Manual

Compact Four-Way Cassette 

IMPORTANT NOTE:

Read this manual carefully before 

installing or operating your new air 

conditioning unit. Make sure to save 

this manual for future reference.

MCA3U-12FNXD0
MCA3U-18FNXC8

MCA3I-09FNXD0

Содержание MCA3I-09FNXD0

Страница 1: ...r s Manual Compact Four Way Cassette IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference MCA3U 12...

Страница 2: ...leitung Produktdaten in der Verpackung des Outdoor Einheit Nur Produkte der Europ ischen Union Nota Importante Leggere con attenzione questo manuale prima di utilizzare il prodotto e conservarlo per l...

Страница 3: ...Indoor Unit Parts and Major Functions 06 Manual Operations 08 Table of Contents Owner s Manual SAFETY FIRST Safety Precautions 04 1 2 3...

Страница 4: ...to Clean the Air Filter 09 c Repairing Refrigerant Leaks 10 d Preparation for Periods of Non use 10 Troubleshooting 11 a Common Problems 11 b Troubleshooting Tips 12 European Disposal Guidelines 14 4...

Страница 5: ...be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater The appliance shall be stored so as to prevent me...

Страница 6: ...he evaporator coils inside the indoor unit The evaporator coils are sharp and may cause injury DO NOT place items that might be affected by moisture damage under the indoor unit Condensation can occur...

Страница 7: ...fe and effective operation If the air conditioner is used under different conditions it may malfunction or become less efficient COOL Mode HEAT mode DRY mode Indoor Temperature 17 32 C 62 90 F 0 30 C...

Страница 8: ...uce the efficiency of the unit Set a timer and use the built in SLEEP ECONOMY mode if applicable If you don t plan to use the unit for a long time remove the batteries from the remote control Clean th...

Страница 9: ...owing order AUTO FORCED COOL OFF FORCED COOL mode In FORCED COOL mode the Operation light flashes The system will then turn to AUTO after it has cooled with a high wind speed for 30 minutes The remote...

Страница 10: ...CE Always turn off your air conditioning system and disconnect the power supply before cleaning or maintenance DO NOT use chemicals or chemically treated cloths to clean the unit DO NOT use benzene pa...

Страница 11: ...alled in a small room measures must be taken to prevent the refrigerant concentration from exceeding the safety limit in the event of refrigerant leakage Concentrated refrigerant causes a severe healt...

Страница 12: ...its setting to prevent frost from forming on the unit Once the temperature increases the unit will start operating again The set temperature has been reached at which point the unit turns off the comp...

Страница 13: ...indoor or outdoor unit is dirty Clean the affected heat exchanger The air filter is dirty Remove the filter and clean it according to instructions The air inlet or outlet of either unit is blocked Tur...

Страница 14: ...er twin model malfunction 10 Off E9 10 Overload protection 1 On F0 11 Outdoor temperature sensor error 2 On F 1 12 Outdoor condenser pipe sensor error 3 On F2 13 Discharge air temperature sensor error...

Страница 15: ...al waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer...

Страница 16: ......

Страница 17: ...Page 16 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 18: ...Installation Manual Compact Four Way Cassette IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future referenc...

Страница 19: ...05 Outdoor Unit Installation 12 a Outdoor Unit Installation Instructions 12 b Drain Joint Installation 13 c Notes on Drilling Hole in Wall 13 Drainpipe Installation 14 Table of Contents Installation...

Страница 20: ...llation Of The Throttle 19 Wiring 20 b Outdoor Unit Wiring 20 c Indoor Unit Wiring 21 a Power Specifications 20 Air Evacuation 22 a Evacuation Instructions 22 b Note on Adding Refrigerant 23 Panel Ins...

Страница 21: ...me models 1 Seal ring some models 1 Installation Accessory some models Ceiling hook 4 Suspension bolt 4 Throttle some units 1 Anti shock rubber 1 1 1 1 1 Owner s manual Installation manual 1 Optional...

Страница 22: ...rce or burn The appliance shall be stored so as to prevent mechanical damage from occurring Only trained and certified technicians should install repair and service this air conditioning unit Improper...

Страница 23: ...ted and stored in a room with a floor area larger than X m Please see the following form The appliance shall not be installed in an unventilated space if that space is smaller than X m Please see the...

Страница 24: ...7 8 Install the indoor unit Page 8 INSTALLATION ORDER Install the outdoor unit Page 12 Install the drainpipe Page 14 Evacuate the refrigeration system Page 22 Connect the wires Page 20 Connect the ref...

Страница 25: ...sing personal injury unit and property damage or even death Install the indoor unit at a height of more than 2 5m 8 above the floor DO NOT install the indoor unit in a bathroom or laundry room as exce...

Страница 26: ...he following locations In areas with oil drilling or fracking In coastal areas with high salt content in the air In areas with caustic gases in the air such as near hot springs In areas with power flu...

Страница 27: ...es Secure the bolt using the included washers and nuts 4 Install the four suspension bolts See Fig 4 4 Step 2 Hang indoor unit 1 Use the included paper template to cut a rectangular hole in the ceilin...

Страница 28: ...board Main body 24mm 0 9 L NOTE Ensure that the indoor unit is level The unit is equipped with a built in drain pump and float switch If the unit is tilted against the direction of condensate flows t...

Страница 29: ...length between the outdoor and indoor unit may not exceed the maximum allowable pipe length If possible DO NOT install the unit where it is exposed to direct sunlight If possible make sure the unit i...

Страница 30: ...m the unit during heating mode NOTE Make sure the water drains to a safe location where it will not cause water damage or a slipping hazard Seal Drain joint A B Base pan hole of outdoor unit Seal Fig...

Страница 31: ...e unit Improper installation may cause unit and property damage CAUTION Insulate all piping to prevent condensation which could lead to water damage If the drainpipe is bent or installed incorrectly w...

Страница 32: ...e installation process Wall Indoor Outdoor 12mm 0 5 inch Fig 6 5 NOTE When drilling the wall hole make sure to avoid wires plumbing and other sensitive components 4 Pass the drain hose through the wal...

Страница 33: ...xic and flammable Ensure there is no refrigerant leakage after completing the installation work Notes On Pipe Length and Elevation Ensure that the length of the refrigerant pipe the number of bends an...

Страница 34: ...he pipe a little longer than the measured distance CAUTION DO NOT deform pipe while cutting Be extra careful not to damage dent or deform the pipe while cutting This will drastically reduce the heatin...

Страница 35: ...m the unit Fig 7 9 Step 2 Remove burrs Burrs can affect the air tight seal of refrigerant piping connection They must be completely removed 1 Hold the pipe at a downward angle to prevent burrs from fa...

Страница 36: ...iagram below DO NOT bend the tubing more than 90 or more than 3 times Bend the pipe with thumb min radius 10cm 3 9 Fig 7 10 6 After connecting the copper pipes to the indoor unit wrap the power cable...

Страница 37: ...per grounding may cause electrical shock DO NOT connect the unit with the power source until all wiring and piping is completed Make sure that you do not cross your electrical wiring with your signal...

Страница 38: ...ip the rubber jacket from both ends of signal cable to reveal about 15cm 5 9 of the wires inside b Strip the insulation from the ends of the wires c Using wire crimper crimp the u lugs to the ends of...

Страница 39: ...he manifold gauge Keep the High Pressure side closed 4 Turn on the vacuum pump to evacuate the system 5 Run the vacuum for at least 15 minutes or until the Compound Meter reads 76cmHG 1x105Pa 6 Close...

Страница 40: ...in the area have been made safe by control of flammable material when the refrigerant added into air conditioner The maximum refrigerant charge amount of R32 is 305 grams DO NOT mix refrigerants types...

Страница 41: ...etach it from the main body Fig 10 1 Fig 10 2 Fig 10 3 Fig 10 4 Step 2 Install the panel Align the indicate on the decoration panel to the indicate on the unit Attach the decoration panel to the unit...

Страница 42: ...rille Step 5 Fasten the control box lid with 2 screws Step 6 Close the intake grille and close the 2 grille hooks Ensure that the buckles at the back of the grille be properly seated in the groove of...

Страница 43: ...oom temperature is being registered correctly d Ensure the indicators on the remote control and the display panel on the indoor unit work properly e Ensure the manual buttons on the indoor unit works...

Страница 44: ...lowing options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufa...

Страница 45: ...azards or ignition risks NO SMOKING signs shall be displayed 2 Work procedure All mintenance staff and others working in the local area shall be instructed on the nature of work being carried out work...

Страница 46: ...rily dealt with If the fault cannot be corrected immediately but it is necessary to continue operation and adequate temporary solution shall be used This shall be reported to the owner of the equipmen...

Страница 47: ...aked flame shall not be used 10 Repairs to sealed components 10 1 During repairs to sealed components all electrical supplies shall be disconnected from the equipment being worked upon prior to any re...

Страница 48: ...lowing leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not b...

Страница 49: ...a manifold so that refrigerant can be removed from various parts of the system 16 Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensu...

Страница 50: ...abelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Empty rec...

Страница 51: ...ions 4 Storage of equipment appliances The storage of equipment should be in accordance with the manufacturer s instructions 5 Storage of packed unsold equipment Storage package protection should be c...

Страница 52: ......

Страница 53: ...Page 36 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details QSBPQ4I 057AEN R32 A3...

Страница 54: ...h for purchasing our air conditioner Please read this owner s manual carefully before using your air conditioner The design and specifications are subject to change without prior notice for product im...

Страница 55: ...detail see sleep operation in USER S MANUAL 1 2 4 5 3 9 10 11 12 13 8 6 7 Temp Mode Fan OK Timer Sleep Turbo LED Fav Options Press this button to modify the air conditioner mode in a sequence of foll...

Страница 56: ...8 6 7 Temp Mode Fan OK Timer Sleep Turbo LED Fav Options RG70C BGEF RG70C1 BGEF Swing Button OK Button Swing Button Used to confirm the optional fucntions Used to stop or start horizontal louver move...

Страница 57: ...ELF CLEAN function Under SELF CLEAN mode the air conditioner will automatically clean and dry the Evaporator and keep it as fresh for the next operation It is not available under heating or fan mode F...

Страница 58: ...ton 3 Press the ON OFF button to start the unit NOTE FAN SPEED can t be changed in DRY mode 1 Press the MODE button to select FAN mode 2 Press FAN button to select the fan speed AUTO LOW MED or HIGH 3...

Страница 59: ...ess After 10 hours and up to 24 it will increase in 1 hour increments The timer will revert to zero after 24 hours You can turn off either function by setting its timer to 2 Press the Temp or button t...

Страница 60: ...a tically turn off at 9 00 PM Example Setting the unit to turn on after 6 hours operate for 2 hours then turn off see the figure below Your remote display Do the following ON OFF ON OFF MODE MODE SHOR...

Страница 61: ...back on NOTE When the batteries are removed the remote controller erases all programming After inserting new batteries the remote controller must be reprogrammed Replacing batteries CAUTIONS The air c...

Отзывы: