background image

Window Air Conditioner

version B - 02 - 2020

MAW12V1

D

WT

MAW10V1

D

WT

MAW08V1

D

WT

midea.com

USER MANUAL

en

MAW

Warning notices: Before using
this product, please read this
manual carefully and keep it for
future reference. For additional
support, please call customer
service at 1-866-646-4332.

The design and specifications are
subject to change without prior
notice for product improvement.
Consult with your dealer or
the manufacturer for details.

Capacity: 8000 ~ 12000BTU/h

version D - 03 - 2020

Free 3 months 

extension*

of the 

original limited warranty 

period! Simply text a 

picture of your proof of 

purchase to:

1-844-224-1614

*The warranty extension is for the

three months immediately following

the completion of the product’s 

original warranty period.

Содержание MAW Series

Страница 1: ...1 866 646 4332 The design and specifications are subject to change without prior notice for product improvement Consult with your dealer or the manufacturer for details Capacity 8000 12000BTU h versio...

Страница 2: ...For support please call the Service Center at 1 866 646 4332 This appliance is not intended for use by people including children with reduced physical sensory or mental capabilities or lack of experie...

Страница 3: ...ice unusual sounds or smells or smoke coming from it A damaged product may cause fire and electric shock Ventilate room before operating the air conditioner if there is a gas leakage from another appl...

Страница 4: ...shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit...

Страница 5: ...c shock If water is spilled on the unit turn off the unit and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician Do not use near gas...

Страница 6: ...anufacturer Grounding type wall receptacle Do not under any circumstances cut remove or bypass the grounding prong Power supply cord with 3 prong grounding plug and current detection device The power...

Страница 7: ...appliance shall also be stored in a room without ignition sources Do not pierce or burn Be aware that the refrigerants may not contain an odor Compliance with national gas regulations shall be observe...

Страница 8: ...LQFRUUHFW LQVWDOODWLRQ Trickling Sound URSOHWV RI ZDWHU KLWWLQJ FRQGHQVHU GXULQJ QRUPDO RSHUDWLRQ PD FDXVH D WULFNOLQJ VRXQG Gurgle Hiss XUJOLQJ RU KLVVLQJ noises may be heard GXH WR UHIULJHUDQW RZLQ...

Страница 9: ...Louvers 6 Once the room has cooled adjust the thermostat to the setting you find most comfortable 7 Make sure the air flow inside and outside is not obstructed by anything Cooling Operation Outdoor t...

Страница 10: ...or off 2 CONNECT Button For the first time using the WiFi function press the button for 3 seconds to initiate the WiFi connection mode The LED DISPLAY shows AP to indicate you can set up the WiFi conn...

Страница 11: ...N buttons to choose the desired temperature When Cool Mode is selected the fan speed can be adjusted by pressing the FAN button To operate on DRY mode In this mode the air conditioner will generally o...

Страница 12: ...the following in the window display of indoor unit EH xx EL xx EC xx PH xx PL xx PC xx Display NOTICE If your problem persists after performing the checks and diagnostics above turn off your unit imm...

Страница 13: ...llation Instructions NOTICE The unit you purchased may look like the following NOTICE All the illustrations in this manual are for explanation purpose only The actual installation may vary Scan the fo...

Страница 14: ...may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils Please wear cut resistant glov...

Страница 15: ...piece of hardware is missing DO NOT INSTALL THE PRODUCT and call customer service at 1 866 646 4332 Angled Support Arms Right Extension Arm Left Extension Arm Spring Push Pin Main Support Rear Cross...

Страница 16: ...your window sill width For windows where the front of the bracket will rest against the vinyl lip these arms will be adjusted in a later step A Before placing the bracket in the window allow the Angle...

Страница 17: ...e outdoors to allow condensate to drain out The proper angle is when the level reads 1 4 bubble reference image for 1 4 bubble Indoor Side Window Frame C Insert the Main Support Pin through the Main S...

Страница 18: ...ey touch the side of the windowsill and are in front of the side window frame Secure the bracket to the window with a screw at the end of each extension arm as shown Holes at the end or bottom of the...

Страница 19: ...tilt towards the outside B Fold both Side Arm Hinges down and measure the distance between the Side Arm Hinge and the Window Frame WARNING Do not leave the unit unattended during installation Install...

Страница 20: ...they touch the window frame Secure the Anti Tip Bracket in place with the provided phillips screw The air conditioner may need to be adjusted front to back so the Anti Tip Brackets align with the Win...

Страница 21: ...injury Top view Anti Tip Bracket Installed in Window Track Opening The images to the left show what a properly installed Anti Tip Bracket into the window track should look like The images to the left...

Страница 22: ...re to fully extend the locks so that they come in direct contact with the window NOTICE For additional security you may use the provided window locking hardware and lock the window in place using the...

Страница 23: ...OCKED BY STORM WINDOW SASH OUTSIDE INSIDE 1 1 2 min 38 mm Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Storm window frame or other obstruction Add...

Страница 24: ...cloth before wiping around the controls Excess water in or around the controls will cause damage to the air conditioner Plug in air conditioner Care and Cleaning 3 Care and Cleaning CAUTION Clean you...

Страница 25: ...e COOL mode Check for potential obstructions blocking the outdoor intake exhaust Clear any obstructions Air conditioner cooling but room is too warm ice forming on cooling coil behind air filter Outdo...

Страница 26: ...ge quantity of moisture from humid room This is normal during excessively humid days Remote sensing deactivating prematurely some models Remote control not located within range Place remote control wi...

Страница 27: ...aking the appliance accessible for servicing 6 Damages to finish after intallation EXCLUSIONS This warranty does not cover the following 1 Failure caused by damage to the unit while in your possesion...

Страница 28: ...he original limited warranty period Simply text a picture of your proof of purchase to 1 844 224 1614 The warranty extension is for the three months immediately following the completion of the product...

Отзывы: