Remove the 2 clips fixing the fan with hands.
8.5 Evaporator and Defrost system(None)
Evaporator in freezing chamber
Evaporator in freezing chamber
1
)
Remove the air duct components in freezing chamber.
2
)
Disconnect all connectors.
3
)
Remove the welding on inlet and outlet tubes.
4
)
Remove two screws which are used to fix the
evaporator and remove the evaporator.
Components on the evaporator
None
1)
Fuse
Disconnect the fuse connector.
2) Cut off the band which fixes the fuse.
3) Separate the fuse and the evaporator.
*
Don’t break the welding of the evaporator in case that
only the fuse needs to be replaced.
Defrost sensor
The defrost sensor is located on top of the evaporator.
1) Disconnect the connector of defrost sensor
2) Cut off the band which fixes the sensor.
3) Separate the sensor and the evaporator.
*
Don’t break the welding of the evaporator in case that
only the sensor needs to be replaced.