Service Manual
, 2016-12
30
/
47
refrigerator and freezer button C
When in the refrigeration mode, long press this button for 3 seconds, then switch to the
freezing mode and restore the default temperature -18
℃
/ 0
℉
;
When in the freezing mode, long press this button for 3 seconds, then switch to the refrigeration
mode and restore the default temperature 5
℃
/41
℉
;
9.2. 6
Celsius \ Fahrenheit units switch
Long press the temperature down button (D key) + the temperature up button (E key) for 3
seconds to switch the Celsius and Fahrenheit display mode.
9.2. 7
Main board reset
Long press the lock/unlock button (B key) + temperature up button (E key) for 3 seconds to
switch to the main board reset mode.
9.2. 8
Maintenance mode
Long press the lock/unlock button (B key) + temperature down button (D key) for 3 seconds
to switch to the maintenance mode.
9.2. 9
Self-test mode
Press the lock/unlock button (B key) + temperature down button (D key) to switch to the
self-test mode in the first 3 seconds when power on.
9.3Alarm
9.3.1
High-temperature alarm
(1)
Refrigeration function
:
When the sensor temperature higher than 15
℃
and duration for more than 36 hours, switch to
over-temperature mode, the light of high temperature alarm on; The buzzer calls 10 seconds by the
frequency of 1 HZ, then call 10 seconds in every 30 minutes.
When the sensor temperature lower than 12
℃,
alarm release. operate any button to cancel the
buzzer alarm.
(2)
Freezing function
:
When the sensor temperature higher than -8
℃
and duration for more than 36 hours, switch to
over-temperature mode, the light of high temperature alarm on; The buzzer calls 10 seconds by the
frequency of 1 HZ, then call 10 seconds in every 30 minutes.
When the sensor temperature lower than -12
℃,
alarm release. Operate any button to cancel the
buzzer alarm.
9.3.2
Door-opening alarm
When the door open, the open indicator on, when the door close, the open indicator off.
Anytime, when the freezing door open more than 5 minutes, switch to the door-opening alarm,
the door-opening alarm indicator on and off once every 1000 ms. the buzzer call once a second
until the door close, operate any button to cancel the buzzer alarm.
9.3.3
Cross-border alarm
When power on more than 40 hours, the temperature of sensor is detected ±7
℃
over than the
setting temperature, continue the test more than 2 hours until push the cross-border alarm to the
APP, if the temperature recover to the range of ±7
℃
, then clear the time to zero.
Note: change the setting temperature, the refrigeration and freezing function, open the door
clear record the time 40 hours and continue 2 hours
When the sensors is fault, clear record the time 40 hours and continue 2 hours,
not cross-border
alarm
Содержание 22031010000841
Страница 5: ...Service Manual 2016 12 5 47 1 Safety Warning Code 1 1Warning for operation safety...
Страница 6: ...Service Manual 2016 12 6 47...
Страница 7: ...Service Manual 2016 12 7 47...
Страница 8: ...Service Manual 2016 12 8 47 1 2Safety instruction for refrigerant...
Страница 37: ...Service Manual 2016 12 37 47 11 Troubleshooting Method 11 1 No refrigeration...
Страница 38: ...Service Manual 2016 12 38 47 11 2 Compressor failure...
Страница 39: ...Service Manual 2016 12 39 47 11 3 Defrosting is not working...
Страница 40: ...Service Manual 2016 12 40 47 11 4 Fan in the freezing chamber is abnormal Refer to this method for other fans...
Страница 41: ...Service Manual 2016 12 41 47 11 5 Damper is abnormal None 11 6 Lights inside the refrigerator don t light up...