background image

 

CP2100A/CP2100B 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CP2100A

Страница 1: ...CP2100A CP2100B ...

Страница 2: ...l and any information contained in it including but not limited to implied guarantees for merchantability and suitability for specific purposes Micsig is not responsible for errors or accidental or consequential damages caused by the provision use or use of this document or any information contained in it If a separate written agreement has been reached between Micsig and the user that contains wa...

Страница 3: ...3 10 1 Product Introduction 5 2 Appearance 5 3 Specifications 6 4 Instructions 9 5 Maintenance 9 ...

Страница 4: ...touch the measured conductor and sensor head during measurement Do not use in a humid environment Do not touch the instrument or the measured object with wet hands Please use this product within the range allowed by the end user Please use this product as required Please ground this product through the USB power cord ...

Страница 5: ...ters via connector The maximum current can be measured to 100Apk 70Arms it has 2 models CP2100A and CP2100B CP2100A can measure bandwidth to DC 800KHz CP2100B can measure bandwidth to DC 2MHz 2 optional measuring ranges 10A and 100A Automatic and manual zero adjustment powered by USB no additional power supply making measurement more convenient Often used in motor drives industrial frequency inver...

Страница 6: ...k 70 7Arms DC ACpk 200Apk pk 70 7Arms AC Maximum working voltage CAT III 300V CAT II 600V Maximum floating voltage CAT III 300V CAT II 600V Maximum conductor diameter 13mm Overload indication The buzzer sounds long and the button light flashes Supplied power DC 5V Probe head size 11 6 1 2 5cm Control box size 10 8 5 6 2 6cm Length 228cm Weight 290g Package weight 1000g Package dimensions 29 5 23 6...

Страница 7: ...7 10 Maximum current VS Frequency curve Amplitude frequency characteristic curve CP2100A ...

Страница 8: ...8 10 Amplitude frequency characteristic curve CP2100B DC signal linearity 0 01V A ...

Страница 9: ...sition of the probe do not move it in a large range after the zero adjustment is completed 5 Open the jaws to clamp the conductor under test according to the direction indicated by the clamp head Note If the measured current flows in the opposite direction to the clamp head the output will be negative 6 Adjust the oscilloscope to get the best waveform Note When the current exceeds the range the bu...

Страница 10: ...10 10 Shenzhen Micsig Instruments Co Ltd Tel 86 755 88600880 Email sales micsig com http www micsig com ...