AutoBaud Disable
Syntax:
<SOH>
AD
<CR>
Description:
Turns off the automatic baud rate detection feature.
When you disable AutoBaud, the controller maintains the communication
rate currently set in non-volatile RAM (NovRAM). The controller continues
to use this communication rate until you change it with either the Parameter
Set command or the AutoBaud Enable command.
AutoBaud Enable is the factory default for some touchscreen controllers.
However, because this automatic feature is limited to the communication
rate, MicroTouch recommends that you issue an AutoBaud Disable
command to turn off the AutoBaud feature. After you disable AutoBaud,
send a Parameter Set command to change the communication parameters
(parity, number of data bits, number of stop bits, and baud rate).
Response:
<SOH>
0
<CR> Positive response.