Chapter 1 Integrating the MT3000 Controller
21
Table 2. LED Diagnostic Codes for MT3000 Controller
LED Flashes
(per 10 seconds)
Self-Test Bit
(UV Command)
Error Description
1
0
Reserved for future assignment.
2
1
ROM error. Firmware checksum verification
error.
3
2
Pulse Width Modulation (PWM) error. Unable to
establish PWM operating range at power-up.
4
3
Block 1 NovRAM error. The operating
parameters in the controller NovRAM are
invalid. Using defaults.
5
4
HDW error. The controller hardware failed
(unable to initialize or configure gate array).
Non-recoverable error.
6
5
Reserved for future assignment.
7
6
Reserved for future assignment.
8
7
Block 2 NovRAM error. The linearization data in
the controller NovRAM is invalid.
Note:
Some errors are non-recoverable, meaning that normal touchscreen
operation cannot occur. Recoverable errors cause the controller to revert to
default values.