background image

  
  
  

 

 Size 

А

3 / 

А

4  

Signature

 and

 Data

 

 

Invent N o

f dou

bl 

 

Subst. of inv

ent 

 

Signature

 and

 Data 

 

Invent N o

f orig

 

6574190580

 

 

TELEVISION MODULE 

 

ТМ

-1104-3 

 
 
 

Operating Manual 

 

ТЭ

3.623.912-03

РЭ

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание TM--1104-3

Страница 1: ...Size 3 4 Signature and Data Invent N of doubl Subst of invent N Signature and Data Invent N of orig 6574190580 TELEVISION MODULE 1104 3 Operating Manual 3 623 912 03...

Страница 2: ...allations 29 2 2 2 External Examination of Device 30 2 2 3 Initial Position of Controls before Use of Device 30 2 2 4 Interconnection with other Devices 30 2 2 5 Switching On and Testing of Device 30...

Страница 3: ...lt into the device generation and reception of control signals during data exchange via RCLI channels with the TM 1215 4 control modules and 1213 terminal module of the TV complex generation and recep...

Страница 4: ...t 1 1 1 4 Device Structure and Operation Modules and units of the device form several functional systems that are parts of the corresponding systems of the TV complex This functional systems are liste...

Страница 5: ...e has a duration of 12 S The centralized synchronization reduces the mutual interference level and simplifies video signal processing The main unit of the genlocking system is the EM 1209 1 controller...

Страница 6: ...1215 4 No 3 control module The reply array contains the codes of the buttons pressed The 1209 1 controller transmits data to the 1211 diagnostics module via channel RCLI 11 The data array contains in...

Страница 7: ...Device 3 257 PERISCOPE 1 2 Fore end 6 frame 1220 1 FE 6FR 1 3 1 room 1 deck starboard side 08 2 1R 1D STB 1 4 1 room 2 deck 08 1 1R 2D 2 1 1 room 1 deck port side 08 1 1R 1D PS 2 2 Superstructure 20...

Страница 8: ...the number of the 1215 4 control module from which the TVD was forwarded for servicing During this the power supply remains connected to the TVD and the video signal of the TVD comes to the correspond...

Страница 9: ...modules having the 1240 interface unit therein and the 118 1 VRD This devices are grouped together in the frame Near the 118 1 VRD its state is shown The following states of the VRD are shown STOP OF...

Страница 10: ...responds to 105 of the rated voltage If the voltage controlled falls out of the tolerance limits the line blinks that is a sign of a fault in the module The output voltages of the three 1213 power sup...

Страница 11: ...voltage 220 V 50 Hz from the 03 switchboard is supplied to the device via a cable through connector XP1 and the assembly unit A1 The device is switched on with toggle switch POWER The three phase volt...

Страница 12: ...er the drop cover 23 to the left of the assembly unit front panel The indicators 28 of phase voltage presence 220 V 50 Hz are fastened on the front panel of the assembly unit The 2 TVM 2 is installed...

Страница 13: ...7 3 V power consumption 50 W maximum dimensions of screen visible area 246 185 mm 2 TVM screen resolution no less than 500 TV lines viewing angle of 2 TVM screen from 100 to 140 deg horizontal from 90...

Страница 14: ...ment is required Quality enhancing image sharpness and noise reduction To finish work with MENU the following modes are used Save Exit save all the settings and leave the menu Cancel Exit cancel all t...

Страница 15: ...vice Prior to the device switch on the POWER toggle switch under the drop cover of the assembly unit should be in the off position To open the drop cover unscrew the captive screws 2 2 4 Interconnecti...

Страница 16: ...a red LED of the TROUBLE group on the 1212 1 control module front panel near the code of a module or a group of modules testifies to malfunction of those For more exact location of the faulty module u...

Страница 17: ...rface with device 2 Remedy replace the 1242 interface unit with the serviceable one from the BSP 2 3 3 12 After replacing a faulty module with a serviceable one make a record in TV complex logbook 1 1...

Страница 18: ...des Examinations No 1 and No 2 in full and also some additional measures cleaning of the device inside of dust with a vacuum cleaner using a soft brush check on the condition of printed circuit tracks...

Страница 19: ...ron off install the cover and fix it with the screws 3 1 4 4 Replacement of the 2 TVM is done as follows undo the four captive screws in the corners of the 2 TVM front panel pull the handles and move...

Страница 20: ...oard spare parts CP control panel CS control system DAC digital to analog converter DGP device genlocking pulse DSP depot spare parts LC liquid crystal LED light emitting diode MC microcontroller P mi...

Страница 21: ...3 623 912 03 3 623 912 03...