11
X22-19688-01
Component Removal and Replacement Procedures
Prior to Device Disassembly:
• Before opening the device, always ensure device is powered off and disconnected from a power supply.
• Always ensure that the work surface is covered with an ESD-safe, soft, non-marring material.
• Work surfaces should be cleaned regularly to ensure debris/abrasive particles are not present.
• Check to make sure that general guidelines and ESD compliance steps are followed prior to opening device.
WARNING:
It is recommended that an ESD-safe battery cover of appropriate size (either 13.5” or 15”
device) be placed across the device to protect the battery from any physical contact or accidental
damage whenever C-cover is removed. Ensure corners of cover are aligned with the corners of the device
at all times while battery is exposed. If battery cover is misaligned during activities in any way, re-align
before continuing activities.
CAUTION:
Check C-cover and device enclosure for any loose articles that may be present inadvertently
on the C-cover or within the device enclosure.
IMPORTANT:
Once the rSSD has been removed, powering on the device requires that the rSSD and
C-cover FRUs are installed and device must be connected to a power supply. Refer to Procedure-Removal
(rSSD) section (
) for details.
IMPORTANT:
Once the rSSD has been removed, powering on the device requires that the rSSD and
C-cover FRUs are installed. Refer to Procedure-Installation (rSSD) section (
.
Current Battery Warning
WARNING:
Please note that the battery bears the following warning label. Please heed the
information provided on the label.
Battery cannot be easily replaced by user
• Risk of fire or burning - contact Microsoft for assistance
•
Do not separate or remove battery from backplate cover
•
Do not modify battery, its wiring, or connectors
•
Do not replace, short circuit, bend, crush, or puncture battery
•
Do not dispose of battery in fire or expose to high temperatures (+140
°
F/60
°
C)
•
For more information: http://aka.ms/surface-security