MS453490M

10 Port Fast Ethernet Switch

Installation Guide

MICROSENS

 GmbH & Co. KG - Kueferstraße 16 - 59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com

Содержание MS453490M

Страница 1: ...MS453490M 10 Port Fast Ethernet Switch Installation Guide MICROSENS GmbH Co KG Kueferstra e 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com...

Страница 2: ......

Страница 3: ...INSTALLATION GUIDE MS453490M 10 PORT FAST ETHERNET SWITCH Layer 2 Switch with 8 10 100BASE TX RJ 45 Ports and 2 Gigabit Combination Ports RJ 45 SFP MS453490M E102010 CS R01 149100000110A...

Страница 4: ......

Страница 5: ...ing to EN 55022 Limit class A for harmonic current emission according to EN 61000 3 2 Limitation of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 Immunity Prod...

Страница 6: ...e des composants optiques ou de la Fibre Optique Danger d aveuglement Couvrir les connecteurs optiques non utilis s d un cache Mettre en service la ligne de transmission une fois que tous les branchem...

Страница 7: ...he socket outlet must be near to the unit and easily accessible You can only remove power from the unit by disconnecting the power cord from the outlet This unit operates under SELV Safety Extra Low V...

Страница 8: ...rd Set U S A and Canada The cord set must be UL approved and CSA certified The minimum specifications for the flexible cord are No 18 AWG not longer than 2 meters or 16 AWG Type SV or SJ 3 conductor T...

Страница 9: ...ortant l appellation Neutre et avec raccordement direct la terre masse Cordon lectrique Il doit tre agr dans le pays d utilisation Etats Unis et Canada Le cordon doit avoir re u l homologation des UL...

Страница 10: ...teeingang haben Die Netzsteckdose mu in der N he des Ger ts und leicht zug nglich sein Die Stromversorgung des Ger ts kann nur durch Herausziehen des Ger tenetzkabels aus der Netzsteckdose unterbroch...

Страница 11: ...erviceable user parts WARNING Installation and removal of the unit must be carried out by qualified personnel only WARNING When connecting this device to a power outlet connect the field ground lead o...

Страница 12: ...cluded electrical components once the product has reached the end of its life MANUFACTURING MATERIALS There are no hazardous nor ozone depleting materials in this product DOCUMENTATION All printed doc...

Страница 13: ...ge of LANs Local Area Networks CONVENTIONS The following conventions are used throughout this guide to show information RELATED PUBLICATIONS The following publication gives specific information on how...

Страница 14: ...ABOUT THIS GUIDE 14 REVISION HISTORY This section summarizes the changes in each revision of this guide OCTOBER 2010 REVISION This is the first revision of this guide...

Страница 15: ...NG 27 Introduction to Switching 27 Application Examples 28 Application Notes 32 3 INSTALLING THE SWITCH 33 Selecting a Site 33 Ethernet Cabling 34 Equipment Checklist 35 Mounting 35 Installing an Opti...

Страница 16: ...TING 49 Diagnosing Switch Indicators 49 Power and Cooling Problems 50 Installation 50 In Band Access 50 B CABLES 51 Twisted Pair Cable and Pin Assignments 51 Fiber Standards 55 C SPECIFICATIONS 57 Phy...

Страница 17: ...ength 45 Table 7 Maximum 1000BASE SX Gigabit Ethernet Cable Lengths 45 Table 8 Maximum 1000BASE LX Gigabit Ethernet Cable Length 46 Table 9 Maximum 1000BASE LH Gigabit Ethernet Cable Length 46 Table 1...

Страница 18: ...TABLES 18...

Страница 19: ...Cable 30 Figure 8 Making VLAN Connections 31 Figure 9 RJ 45 Connections 34 Figure 10 Attaching the Adhesive Feet 36 Figure 11 Inserting an SFP Transceiver into a Slot 37 Figure 12 Power Socket 38 Fig...

Страница 20: ...FIGURES 20...

Страница 21: ...res for Layer 2 switching delivering reliability and consistent performance for your network traffic It brings order to poorly performing networks by segregating them into separate broadcast domains w...

Страница 22: ...prevents errors from being propagated throughout the network NETWORK MANAGEMENT OPTIONS With a comprehensive array of LEDs the switch provides at a glance monitoring of network and port status The sw...

Страница 23: ...ctor Pluggable SFP transceiver slots are shared with the two 1000BASE T RJ 45 ports ports 9 10 In the default configuration if an SFP transceiver purchased separately is installed in a slot and has a...

Страница 24: ...ng are shown below and described in the following tables Figure 3 Port LEDs 1000BASE LX 50 125 1300 550 m 62 5 125 1300 550 m 9 125 1300 10 km 1000BASE LH 9 125 1310 35 km 1550 80 km 1000BASE T 100 m...

Страница 25: ...1000 Mbps network connection Flashing indicates activity On Flashing Amber Port has established a valid 10 100 Mbps network connection Flashing indicates activity Off There is no valid link on the po...

Страница 26: ...TER 1 Introduction Description of Hardware 26 POWER SUPPLY SOCKET There is one power socket on the rear panel of the switch The standard power socket is for the AC power cord Figure 4 Power Supply Soc...

Страница 27: ...experiencing congestion server power user or hub can be attached directly to a switched port And by using full duplex mode the bandwidth of the dedicated segment can be doubled to maximize throughput...

Страница 28: ...build on this basic configuration adding direct full duplex connections to workstations or servers When the time comes for further expansion just connect to another hub or switch using one of the Fas...

Страница 29: ...e efficient bridged node increasing overall bandwidth and throughput In the figure below the 100BASE TX ports on the switch are providing 100 Mbps connectivity for up to 8 segments In addition the swi...

Страница 30: ...BASE LH link up to 80 km This allows the switch to serve as a collapsed backbone providing direct connectivity for a widespread LAN The figure below illustrates the switch connecting multiple segments...

Страница 31: ...e explicitly tagged to identify the VLAN group to which it belongs Untagged VLANs can be used for small networks attached to a single switch However tagged VLANs should be used for larger networks and...

Страница 32: ...unless it is actually required to solve a problem Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub 3 Based on recommended standards the lengt...

Страница 33: ...ace approximately two inches on all sides for proper air flow be accessible for installing cabling and maintaining the devices allow the status LEDs to be clearly visible Make sure twisted pair cable...

Страница 34: ...k Cable type Unshielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 3 or better for 10BASE T Category 5 or better for 100BASE TX and Category 5 5e or 6 for 1000...

Страница 35: ...n be sure you have all other necessary installation equipment PACKAGE CONTENTS Fast Ethernet Switch MS453490M Four adhesive foot pads Power Cord either US Continental Europe or UK RJ 45 to RS 232 cons...

Страница 36: ...are at least two inches of space on all sides for proper air flow 3 If installing a single switch only go to Connecting to a Power Source on page 38 4 If installing multiple switches attach four adhe...

Страница 37: ...H To install an SFP transceiver do the following 1 Consider network and cabling requirements to select an appropriate SFP transceiver type 2 Insert the transceiver with the optical connector facing ou...

Страница 38: ...Ds as the device is powered on to be sure the Power LED is lit If not check that the power cable is correctly plugged in NOTE SFP transceivers are hot swappable The switch does not need to be powered...

Страница 39: ...to the console port as illustrated below The PIN assignments used to connect to the serial port are described below Figure 13 Console Cable WIRING MAP FOR SERIAL CABLE The serial port s configuration...

Страница 40: ...CHAPTER 3 Installing the Switch Connecting to the Console Port 40 Parity None Stop bit One Data bits 8 Flow control none...

Страница 41: ...ds Use Category 5 5e or 6 cable for 1000BASE T connections Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T connections CABLING GUIDELINES The RJ 45 ports on the s...

Страница 42: ...nected to the wiring closet See the section Fiber Optic SFP Devices Otherwise attach the other end to an available port on the switch Make sure each twisted pair cable does not exceed 100 meters 328 f...

Страница 43: ...ean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable and lead to degraded performa...

Страница 44: ...sure that the connection is valid The 1000BASE SX 1000BASE LX 1000BASE LH fiber optic ports operate at 1 Gbps full duplex with auto negotiation of flow control The maximum length for fiber optic cable...

Страница 45: ...tallations Category 5e enhanced Category 5 or Category 6 cable should be used The Category 5e and 6 specifications include test parameters that are only recommendations for Category 5 Therefore the fi...

Страница 46: ...ft 6 2 miles LC Table 9 Maximum 1000BASE LH Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9 125 micron single mode fiber N A 2 m 80 km 7 ft 49 7 miles LC Tabl...

Страница 47: ...e guidelines Clearly label the opposing ends of each cable Using your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devi...

Страница 48: ...CHAPTER 4 Making Network Connections Cable Labeling and Connection Records 48...

Страница 49: ...ndition If the condition does not clear contact your dealer for assistance Link LED is Off Verify that the switch and attached device are powered on Be sure the cable is plugged into both the switch a...

Страница 50: ...l the other components are functioning properly IN BAND ACCESS You can access the management agent in the switch from anywhere within the attached network using Telnet a web browser or other network m...

Страница 51: ...ite stripes Also an RJ 45 connector must be attached to both ends of the cable The figure below illustrates how the pins on the RJ 45 connector are numbered Be sure to hold the connectors in the same...

Страница 52: ...r end of the cable When using any RJ 45 port on this switch you can use either straight through or crossover cable Note The and signs represent the polarity of the wires that make up each wire pair ST...

Страница 53: ...r crossover cable to connect to any device type You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet Figure 18 Crossover Wiring White Orange Stripe Orange...

Страница 54: ...g information is specified in the ANSI TIA EIA TSB 67 standard Additionally cables must also pass test parameters for Return Loss and Equal Level Far End Crosstalk ELFEXT These tests are specified in...

Страница 55: ...mmarized in the following table Table 15 Fiber Standards ITU T Standard Description Application G 651 Multimode Fiber 50 125 micron core Short reach connections in the 1300 nm or 850 nm band G 652 Non...

Страница 56: ...smission in the 1500 to 1600 nm region with low loss in the 1550 nm band G 655 Non Zero Dispersion Shifted Fiber Single mode 9 125 micron core Extended long haul applications Optimized for high power...

Страница 57: ...to MDI X 10BASE T RJ 45 100 ohm UTP cable Category 3 or better 100BASE TX RJ 45 100 ohm UTP cable Category 5 or better 1000BASE T RJ 45 100 ohm UTP or STP cable Category 5 5e or 6 Maximum Cable Length...

Страница 58: ...1 42 inches TEMPERATURE Operating 0 C to 45 C 32 F to 113 F Storage 40 C to 70 C 40 F to 158 F HUMIDITY Operating 10 to 90 non condensing AC INPUT 100 to 240 V 50 60 Hz 0 2A POWER SUPPLY Internal aut...

Страница 59: ...MODE Store and forward THROUGHPUT Wire speed FLOW CONTROL Full Duplex IEEE 802 3x Half Duplex Back pressure MANAGEMENT FEATURES IN BAND MANAGEMENT SSH Telnet SNMP or HTTP OUT OF BAND MANAGEMENT RS 232...

Страница 60: ...Full duplex flow control Link Aggregation Control Protocol IEEE 802 1D 2004 Spanning Tree Protocol Rapid Spanning Tree Protocol Multiple Spanning Tree Protocol ISO IEC 8802 3 COMPLIANCES EMISSIONS EN...

Страница 61: ...specification for Gigabit Ethernet over two strands of 50 125 62 5 125 or 9 125 micron core fiber cable 1000BASE SX IEEE 802 3z specification for Gigabit Ethernet over two strands of 50 125 or 62 5 12...

Страница 62: ...ystem developed and standardized by DEC Intel and Xerox using baseband transmission CSMA CD access logical bus topology and coaxial cable The successor IEEE 802 3 standard provides for integration int...

Страница 63: ...and physical layer specifications for 100BASE TX Fast Ethernet Now incorporated in IEEE 802 3 2005 IEEE 802 3X Defines Ethernet frame start stop requests and timers used for flow control on full duple...

Страница 64: ...MHz per km which indicates the amount of bandwidth supported by the fiber for a one km distance NETWORK DIAMETER Wire distance between two end stations in the same collision domain RJ 45 CONNECTOR A c...

Страница 65: ...oo slow or just unnecessary UTP Unshielded twisted pair cable VIRTUAL LAN VLAN A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location...

Страница 66: ...GLOSSARY 66...

Страница 67: ...EMC 60 safety 60 connectivity rules 10 Mbps 46 100 Mbps 46 1000 Mbps 45 console port pin assignments 39 contents of package 35 cooling problems 50 cord sets international 38 D desktop mounting 35 dev...

Страница 68: ...38 R rack mounting 35 rear panel of switch 21 rear panel socket 26 RJ 45 port 23 connections 41 pinouts 54 RMON 22 RS 232 port 22 rubber foot pads attaching 36 S serial cable 22 port 22 SFP transceive...

Страница 69: ......

Страница 70: ...MS453490M E102010 CS R01 149100000110A...