Module presentation 

 
 

 

 

 

 
 

MS430943/4M family is a one slot wide FlexRate (100G/200G) module with the 
following characteristics: 

 

Two configurable 100 Gigabit Ethernet / OTU4 client port interfaces 

 

Two operational modes: 

o

 

200G Metro Reach (MR) Transponder 

o

 

100G Ultra Long Haul (ULH) Transponder 

 

FlexRate 200G Muxponder family is composed of 2 versions: 

o

 

Dual Fiber (MS430943M) 

o

 

Single Fiber (MS430944M) 

 

QSFP28 modules for client port physical interfacing 

 

Connectors are LC/PC. 
The FlexRate client traffic type is 100GbE or OTU4. 

 

 
 

 
 

 
 

 
 

 
 
 

MICROSENS 

FlexRate Muxponder (MS430943/4M) - 
Quick Start Manual 

Содержание MS430943M

Страница 1: ...Two operational modes o 200G Metro Reach MR Transponder o 100G Ultra Long Haul ULH Transponder FlexRate 200G Muxponder family is composed of 2 versions o Dual Fiber MS430943M o Single Fiber MS430944M...

Страница 2: ...ig On Web interface Select the module Right Click Configuration Start Up On CLI configure_pm c slot_number SAFETY WARNING By default the line Tx and all the client ports are In Service It means that a...

Страница 3: ...LC PC attenuator to adjust the input power and be as close as possible of the typical value Mode configuration The FlexRate Muxponder is able to work in 200G MR or in 100G ULH bitrate mode By default...

Страница 4: ...a different wavelength on TX and on Rx line side to allow the single fiber transmission mode On Web interface Select the module Right Click Configuration X1 Line1 On CLI set_config slot_number X1 Line...

Страница 5: ...lient1 set_config slot_number X1 Line1 For unused client it is recommended to set the client port s Out Of Service to not interfere with the management of the port s in service Client traffic type Cli...

Страница 6: ...ace Select the Line Right Click Configuration X1 Line1 On CLI set_config slot_number Q1 Client1 for client1 set_config slot_number X1 Line1 STEP 4 End of installation Leds status Verify that all the l...

Страница 7: ...llowing table for module characteristics On Web interface Select the module Right Click Monitoring Counters for Qi Client i and X1 Line1 On CLI get_measurement slot_number X1 Line1 for Line Remote Net...

Страница 8: ...should be below 1x10 3 to assure a proper transmission without uncorrected errors On Web interface Select the module Right Click Monitoring Counter On CLI get_counters slot_number X1 Line1 MICROSENS...