![Microsemi SyncServer S350i Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/microsemi/syncserver-s350i/syncserver-s350i_user-manual_1788478155.webp)
Using NTP
the name of your country at the end of the search string. When available, select NTP servers
that are stratum 1 over those that are stratum 2.
To add a server association:
1. Go to
NTP - Config
in the web interface.
2. Under
Add/Edit Association
, for
Role
, select
Server
.
3. For
Address
, enter an IP address (recommended) or domain name.
4. (Optional) Configure the other settings under
Add/Edit Association.
For more inform-
ation, see
NTP - Config
(on page 43).
5. Click
SAVE
.
6. Click
RESTART
.
After restarting, the NTP daemon sends regular requests to the server and uses the replies
to compare the NTP server with other servers and peers. The NTP daemon selects the best
server or peer and synchronizes with it.
Also see
Configuring NTP Clients
(on page 158).
AddingPeer Associations
A pair of
peer
associations lets two NTP servers evaluate each other as part of their clock
selection algorithms, but prevents "timing loops" where both servers lock to each other. This
approach is typically applied to clusters of NTP servers on a LAN or WAN, and provides
excellent synchronization and redundancy.
To create a pair of peer associations:
1. On the SyncServer, go to
NTP - Config
in the web interface.
2. Under
Add/Edit Association
, for
Role
, select
Peer
.
3. For
Address
, enter the IP address (recommended) or domain name of the peer.
4. (Optional) Configure the other settings under
Add/Edit Association.
For more inform-
ation, see
NTP - Config
(on page 43).
5. Click
SAVE
.
6. Click
RESTART
.
7. Log into the other NTP server and repeat the process of creating a peer association that
points to the IP address or domain name of the SyncServer. For example, on a generic
NTP daemon, add the following line to the ntp.conf file:
peer 192.168.61.54
VerifyingServerandPeerAssociations
After configuring server and peer associations, verify that they are reachable.
To verify
the factory default configuration
, observe the SYNC LED for several minutes after
turning the power on. If the SYNC LED transitions from red to orange (stratum 2), the Syn-
cServer has synchronized with one of three default NTP servers. (Afterward, if the SYNC
LED transitions from orange to green the SyncServer has synchronized to a Hardware
Clock Input Reference and is operating at stratum 1.)