MMUART Peripherals
UG0331 User Guide Revision 15.0
501
13.4.15 Multi-Mode Control Register 1 (MM1)
13.4.16 Multi-Mode Control Register 2 (MM2)
Table 486 •
MM1
Bit
Number
Name
R/W
Default
State
Description
[7:6]
Reserved
R/W
0
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read- modify-write operation.
5
EITP
R/W
0
Output pulse width for RZI mod can be modified using this bit.
0: 3/16
th
Tbit pulse width (default).
1: 1/4
th
Tbit pulse width.
4
EITX
R/W
0
You can configure output polarity for RZI modulation.
0: RZI output pulses are active Low and signify a low NRZ value (default).
1: RZI output pulses are active High and signify a high NRZ value.
3
EIRX
R/W
0
You can configure input polarity for RZI demodulation.
0: RZI input pulses are active Low, signifying a low NRZ value (default).
1: RZI input pulses are active High, signifying a high NRZ value.
2
EIRD
R/W
0
Enables RZI modulation/demodulation.
0: Disabled (default)
1: Enabled
1
E_MSB_TX R/W
0
LSB or MSB can be sent first by configuring this bit. By default, the
bit 0 is the LSB, and is the first transmitted bit. Bit 0 of the THR may be
configured as the last transmitted bit, MSB.
0: THR's bit 0 is the first transmitted bit, LSB (default).
1: THR's bit 0 is the last transmitted bit, MSB.
0
E_MSB_RX R/W
0
LSB or MSB can be received first by configuring this bit. By default, the
receiver buffer register's (
) bit 0 is the LSB, and is the first received
bit. Bit 0 of the
may be configured as the last received bit, MSB.
0: RBR's bit 0 is the first received bit, LSB (default).
1: RBR's bit 0 is the last received bit, MSB.
Table 487 •
MM2
Bit
Number
Name
R/W
Reset
Value
Description
[7:4]
Reserved
R/W
0
The software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read- modify-write operation.
3
ESWM
R/W
0
Enable single-wire, half-duplex mode.
0: Disabled (default)
1: Enabled
2
EAFC
R/W
0
Enable a flag clear (EAFC). When EAFM is enabled the Rx FIFO is
disabled until another address flag with matching address is received. The
bit gets cleared on write in multi-mode control registers 2.
0: Disabled (default)
1: Enabled
Содержание SmartFusion2 MSS
Страница 1: ...UG0331 User Guide SmartFusion2 Microcontroller Subsystem ...
Страница 166: ...Cortex M3 Processor Reference Material UG0331 User Guide Revision 15 0 132 ...
Страница 200: ...Embedded NVM eNVM Controllers UG0331 User Guide Revision 15 0 166 Figure 87 System Builder Window ...
Страница 407: ...Universal Serial Bus OTG Controller UG0331 User Guide Revision 15 0 373 ...
Страница 806: ...Fabric Interface Controller UG0331 User Guide Revision 15 0 772 Figure 345 FIC Master AHB Lite Subsystem ...