Microscan QX-830 Скачать руководство пользователя страница 1

Copyright ©201

5

 Microscan Systems, Inc.

P/N 83-210830 Rev D

Hardware Required

Pin Assignments

Item

Description

Part Number

1

QX-830 Compact Industrial Scanner

FIS-0830-XXXXG

2

QX-1 Interface Device

98-000103-02

3

QX Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m

61-000162-02

4

QX Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m

61-000152-02

5

QX Cordset, Host, Serial, M12 12-pin Socket to DB9 Socket, 1 m

61-000153-02

6

QX Power Supply, 24V, 100-240VAC, +24VDC, M12 12-pin Socket

97-000012-01

7

QX Cordset, Host, Ethernet, M12 8-pin Plug (Ultra-Lock) to RJ45, 1 m

61-000160-01

or

QX Cordset, Host, Ethernet, M12 8-pin Plug (Screw-On) to RJ45, 1 m

61-000160-02

8

QX Cordset, M12 12-pin Plug / M12 12-pin Socket to MS-Connect 210, RS-232, 2 m

61-000158-03

9

QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m

99-000020-02

Note:

 Additional cordsets and accessories are available in the Microscan Product Pricing Catalog.

+10-28V

Trigger

Ground

Trigger/New Master / Input 1 Common

Ground

Output 3

Output 1

Output 2

New Master

Default

Power

Input Common

Output Common

RS-232  RxD

Trigger

RS-232  

TxD

QX-830 (Back View)

QX-1 Interface 

Device (Top View)

Input 

Common

RS-422/485 RxD (–)

RS-232 TxD/

RS-232 RTS

Trigger

RS-232 RxD/

RS-232 CTS

Power

Ground

RS-422/485 

RxD (+)

RS-422/485 

TxD (+)

RS-422/485 TxD (–)

Input 1

Terminated

Connector A (All Models) 

M12 12-pin Plug

Connector B (Serial Models) 

M12 12-pin Socket

QX-1 Trigger Connector 

4-pin Socket

Connector A

 is a serial M12 12-pin plug. It is the same for all 

models of the QX-830.

Connector B 

is a serial M12 12-pin socket for serial models and 

an Ethernet M12 8-pin socket for Ethernet models.

Important: 

See the 

QX-830 Compact Industrial Scanner User 

Manual

 for a list of the wire colors that correspond to each pin.

Connector T

 on the QX-1 Interface Device is the trigger connector.

Connectors 1

2

, and 

3

 can be used to bus power and data as 

required by the application.

TX (+)

RX (–)

RX (+)

TX (–)

Terminated

Terminated

Connector B (Ethernet Models) 

M12 8-pin Socket

Terminated

Terminated

POWER

TRIGGER

1, 3, T

1, 2, 3, T

1, 2, 3

1, 3

QX–830

 

Compact Industrial Scanner

Configuration Guide