Read Rate
MS-850 Raster Scanner User’s Manual
4-5
4–Ut
ili
ties
Enable Extended Rate Test for Single and Multi-label
Clicking any of the Read Rate modes along with
Extended Mode
applies to both
single and multiple labels. It instruct the scanner to output the transition data along
with the data from the latest test command sent. For example, extended mode
along with single or multiple decodes per second would display the decode rate,
label data, and transition data.
Associated serial command:
<Ce>
after
<C>
,
<Cs>
,
<C>
,
or
<Cs>
Note:
The <Ce> command has no immediate effect if not preceded by <C>, <Cs>,
<C>, or <Cs>
.
Enable PDF Information
Clicking the
PDF Info
check box will cause PDF 417 symbology data to be prefaced
with information consisting of error correction level, number of rows, number of col-
umns, number of informative code words and the number of data characters.
Explanation of above PDF Info sample of a PDF 417:
Level = 5 tells you that the error correction level is level 5. There are 13 rows and 6
columns. There are 14 info code words, and 16 characters in the data.
This feature can be disabled by using the exit read rate command <J>.
Associated serial command:
<a1>