Chapter 3
Serial Configuration
3-20
MS-850 Raster Scanner User’s Manual
3–Ser
ial
Conf
ig.
Output-3
Format: <
K‘
output on,polarity,pulse width,# before output
>
Example: To set Output-3 to Mismatch and change Pulse Width to 40 ms, send
<K‘2,0,4> or <K‘2,,4>.
Bar Code Output
Format: <
Kl
status,when to output
>
Example: To set When to Output to End of Read Cycle, send <Kl3,1>.
Scanner Output Status Request
Format: <
KX?
>
Returns status of each command in the Scanner Output group.
output on (mode):
0 =
Mismatch or Noread
1 = Match (or Good Read)
2 = Mismatch
3 = Noread
polarity:
0 =
Negative
1 = Positive
pulse width:
Default is
5
(50 ms)
.
1 to 255
# before
output:
Default is
1
.
1 to 255
status:
0 =
Disabled
1 = Match
2 = Mismatch
3 = Good Read
when to output:
0 =
As Soon As Possible
1 = End of Read Cycle