Output Menu
MS-850 Raster Scanner User’s Manual
2-33
2–Menu C
o
n
fig
.
Output Menu
In addition to decoded data output, the MS-850 outputs serial messages, warnings,
status reports, and pulses which activate (close or open) opto-isolated signals on pin
pairs 6/20, 8/21, and 15/22 (Outputs -1,-2, and -3 respectively) and are individually
configured under conditions set in Output-1, Output-2 and Output-3.
Output-1, Output-2, and Output-3 can allow simultaneous output under individually
programmed conditions.
DEFAULT
Clicking the
DEFAULT
button will reset all parameters on the current menu to defaults.
This does not take effect until it is saved to the scanner with the
SEND/NO SAVE
or
SEND/SAVE
buttons.
Noread Message
Default:
NOREAD
Options:
Up to seven ASCII characters (except NUL)
Allows you to define any combination of ASCII characters (except NUL) up to seven
characters as the noread message. When enabled, and if no bar code label has been
decoded before timeout or the end of the read cycle, the noread message will be
transmitted to the host.
Noread Message (enable/disable)
Default:
Enabled
Options:
Enabled, Disabled
Note:
If Noread Output is enabled, the noread message will only output if Bar Code
Output is also enabled.
Allows you to enable or disable the noread message.
Laser On/Off
Default:
Disabled
Options: Disabled,
Enabled
Note:
A serial or external trigger must be enabled for Laser On/Off to take effect.
When enabled, the laser is ON only during the read cycle. When disabled, the laser
operates continuously.
Note:
Laser On/Off does not relate to the <H> (Enable Laser Scanning) or <I> (Dis-
able Laser Scanning) operational commands.