Operations Menu
MS-850 Raster Scanner User’s Manual
2-13
2–Menu C
o
n
fig
.
Operations Menu
The Operations menu allows you to set the operations parameters for the scanner.
DEFAULT
Clicking the
DEFAULT
button will reset all parameters on the current menu to
defaults. This does not take effect until it is saved to the scanner with the
SEND/NO
SAVE
or
SEND/SAVE
buttons.
Note
:
Clicking the Default button will only restore those settings of the specific menu
on which the button appears.
Good Decode Reads
Default:
1
Options: 1
to
31
Allows you to select the number of good reads (from 1 to 31) required per label
before a good decode output.
Note
:
Be sure to set the value within the determined scan rate for the scanning setup
so that the scanner is capable of scanning a label the required number of times.
Timeout (in 10 ms incs)
Default:
100
(one second). Corresponds to 1000 ms displayed in the menu.
Options:
0 to 65535. (Divide the number entered on the command line by 100 for
time in seconds.)
Note
:
Timeout or Timeout & New Trigger under End of Read Cycle must be enabled
for Timeout (in 10 ms incs) to take effect.
Allows you to define the duration of the timeout period.
Trigger Filter
Default:
78
(approximately 10 ms). Corresponds to 9984 µs displayed in the menu.
Options:
2 to 255 (approximately 0.256 ms to 32 ms in 0.128 ms increments). Multi-
ply the number entered on the command line by 128 for time in microsec-
onds, then divide by 1000 for time in milliseconds.
Allows you to set a trigger bounce filter duration.