Setting Up Partial Scan
System Components
2
HAWK MV-4000 Smart Camera Guide
2-51
Setting Up Partial Scan
Sensor WOI Limitations
The combination of
X Offset
and
Y Offset
determines the location of the
top left corner
of the window of interest (WOI).
Stride
determines the width of the WOI.
Rows
determines the height of the WOI.
All the highlighted fields shown in the example above
must
be changed when creating a
partial scan camdef. The file name must also be changed, showing the WOI size in the name.
•
X Offset:
This value must be a multiple of 32.
•
Y Offset:
This value must be a multiple of 2.
•
Stride:
This value must be a multiple of 32.
•
Rows:
This value must be a multiple of 2.
Minimum size X of 32. Maximum value to whole sensor size.
Minimum size Y of 2. Maximum value to whole sensor size.
Содержание HAWK MV-4000
Страница 1: ...HAWK MV 4000 Smart Camera Guide 84 9007433 02 Rev A ...
Страница 9: ...HAWK MV 4000 Smart Camera Guide 1 1 1 Introduction 1 CHAPTER 1 Introduction HAWK MV 4000 Smart Camera ...
Страница 21: ...HAWK MV 4000 Dimensions System Components 2 HAWK MV 4000 Smart Camera Guide 2 7 Standard HAWK MV 4000 Back ...
Страница 22: ...Chapter 2 System Components 2 8 HAWK MV 4000 Smart Camera Guide Standard HAWK MV 4000 Side ...
Страница 23: ...HAWK MV 4000 Dimensions System Components 2 HAWK MV 4000 Smart Camera Guide 2 9 Standard HAWK MV 4000 Base ...
Страница 66: ...Chapter 2 System Components 2 52 HAWK MV 4000 Smart Camera Guide ...
Страница 94: ...Appendix C General Specifications C 14 HAWK MV 4000 Smart Camera Guide ...
Страница 98: ...Appendix D MVMonitor Web Page D 4 HAWK MV 4000 Smart Camera Guide ...
Страница 106: ...Appendix E CloudLink Web HMI E 8 HAWK MV 4000 Smart Camera Guide ...
Страница 114: ...Appendix F Serial Commands F 8 HAWK MV 4000 Smart Camera Guide ...
Страница 134: ...Appendix G Operating System Save and Restore G 20 HAWK MV 4000 Smart Camera Guide ...