MICRONOR AG
MR340-1 DIN Rail Module Controller
Page 68 of 74
8.
MR340-1 Reprogramming the Firmware
Over time as the firmware functionality is expanded, it may become necessary to reprogram
the firmware. The firmware resides in permanent flash memory which can be re-programmed
with the appropriate software.
Download from the Micronor web site:
-
REFLASH-MR302
•
Install this software on your PC.
Request from Micronor or the authorized Service representative the new Firmware:
-
MR302-DIN_V1pxpxx.hex
Note: Only controllers with Firmware Version 1.1.22 or higher are capable of being reflashed.
Setup the MR340-1 as
shown to the left.
Connect the USB cable to
the PC.
Power the unit with a
suitable 24V DC supply.
Prepare a paper clip or a
small pin able to reach the
reset button on the
MR340-1 unit.
Disconnect sensor from
Unit