                                                                SAFETY PRECAUTIONS 

WARNING: 

Following  these  basic  precautions  will  reduce  the

 

risk  of  fire,  electrical  shock,  injury  or  death  when  using  your

 

air conditioner.

 

1. Air conditioner must be connected to proper electrical outlet or breaker with the correct 

Electrical supply. And only the specified power can be used. 

2. Proper grounding must be ensured to reduce the risk of shock and fire 

DO NOT CUT

 OR REMOVE THE GROUNDING PRONG.  If you do not have a 

Three-prong electric  receptacle  outlet  or  breaker in  the  wall,  have  a certified  electrician

 

install the proper receptacle or breaker. The wall receptacle or breaker MUST be properly

 

grounded. 

3. 

DO NOT 

use if power cord is frayed or otherwise damaged. Also avoid using it if there

 

are cracks or abrasion damage along the length, plug or connector. 

4. 

DO NOT 

USE AN ADAPTER OR AN EXTENSION CORD. 

5. 

DO NOT 

block airflow inside or outside the air conditioner with blinds, drapes, protective

 

covers, shrubs or blusher. 

6. Be careful of sharp edges on the front and rear fins of the unit that could cut and cause

 

serious injury. 

7. Be careful when lifting the air conditioner to install or remove the unit. Always use two or

 

more people for this. 

8. Always cut off the power of air conditioner before servicing it or moving it. 

9. In  some  type  of  units,  there  is  no  appropriate  plug  corresponding  to  its  power  cord

 

because  of  power,  under  this  condition,  an  appropriate  power  breaker  should  be

 

linked to its power cord, therefore, the instruction part associated with plug using is not

 

available for these types. 

10.  An  all-pole  disconnection  switch  having  a  contact  separation  of  at  least  3mm  in  all

 

poles should be connected in fixed wiring. 

11. The appliance shall be installed in accordance with national wiring regulations. 

12.  This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced

 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless

 

they have been given supervision or instruction concerning use of the appliance by a

 

person responsible for their safety. Children should be supervised to ensure that they

 

do not play with the appliance. 

Содержание Environ 1.5T

Страница 1: ...ul of sharp edges on the front and rear fins of the unit that could cut and cause serious injury 7 Be careful when lifting the air conditioner to install or remove the unit Always use two or more peop...

Страница 2: ...rigerant leakage may be resulted as well Operating instruction Please operate air conditioner in accordance to this manual If the power cable to the unit is disconnected burnt chipped or detached from...

Страница 3: ...utlet or breaker Do not under any circumstances cut or remove the third ground prong from the power cord Adapter plug We strongly advise against using an adapter plug or breaker Operating conditions 1...

Страница 4: ...e dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures The appliance shall be installed in accordance with nat...

Страница 5: ...hen there is operating gas equipment Do not switch on or off the unit by plugging or pulling off the plug or by switching on or off the breaker Do not put anything on the outdoor unit Do not put finge...

Страница 6: ...re flammable gas may leak Switch off the unit cut off the power source and contact service agent if there is abnormal phenomenon e g burning smell comes out Do not pull off the power plug or switch of...

Страница 7: ...oling mode in order to keep dry condition inside the unit Reset power or Auto restart alternative Reset power When there is a power suspension air conditioner will automatically switch off When the po...

Страница 8: ...s Outdoor unit Air inlet back Air outlet Drain pipe Remarks The air conditioner is consisting of indoor unit outdoor unit and remote controller The design and shape are different for different models...

Страница 9: ...isplay is for reference only subject to the actual product Remarks 1 Flashing of any indicator means the air conditioner runs abnormally please contact the distributor in time 2 Function a The air con...

Страница 10: ...COOL SWEEP DRY mode TIMER indicator Yellow This indicator lights yellow when the unit is in TIMER mode AIR REFRESH indicator Green optional This indicator lights green when the unit is in Air Refresh...

Страница 11: ...Set the air conditioner operating in low noise Timer selection Button Press this button to Select timer Remarks CLEAN Button Press this button to turn on self cleaning Function LOCK Button Press this...

Страница 12: ...ontroller under the sunlight or near the oven Don t sprinkle water or juice on the remote controller use soft cloth for cleaning if it occurs The batteries must be removed from the appliance before it...

Страница 13: ...unit with water or it may cause electric shock 2 Do not clean the remote controller with water 3 Do not clean with alcohol gasoline banana oil or polishing 4 Do not clean the unit violently or it may...

Страница 14: ...for Long Time 1 Swing 3 4 hours to dry the internal 2 Stop operation by remote controller then air conditioner Cut off the power source of air conditioner 3 Maintain air filter net 4 Take out batterie...

Страница 15: ...ensures high efficiency operation Close Doors and Windows Incoming outdoor air will affect the cooling or heating efficiency Avoid Heat Sources When it is cooling using other heat sources may affect c...

Страница 16: ...rs 4 Check whether doors or windows are closed 5 Check whether fan speed or set temperature is improper Remote Controller is in Error The following trouble shooting is normal phenomenon Phenomenon Che...

Страница 17: ...nit when the compressor stops there will be a 3 minute delay before restarting Walls carpet furniture or clothes indoors may disseminate peculiar smell There may be gentle rustle sound when the unit s...

Страница 18: ......

Страница 19: ...Installation Manual...

Страница 20: ...d cut and cause serious injury 7 Be careful when lifting the air conditioner to install or remove the unit Always use two or more people for this 8 Always cut off the power of air conditioner before s...

Страница 21: ...3 13 14 15 16...

Страница 22: ...lt your supply authority for system information The plug shall be accessible after installed the appliance This instruction is subject to change without notice Installation ofAccessories Examine caref...

Страница 23: ...ont rear left and right sides must be located in an open area The outlet is proposed to be in open air any obstacle will affect the performances The installing distance must be required as Fig 2 shows...

Страница 24: ...tallation board on the wall with M5x30 screws and washer 6 Ensure that there must be at least 4 fixed points in the wall Ensure installation board to horizontal position Drill holes as Fig 4 shows The...

Страница 25: ...ut at the below Pipeline Remove the board which is on the chassis Check if the connections are reliable Units connecting wires Fig 6 Drain pipe Mount the indoor unit on the two hooks at the upper part...

Страница 26: ...s to prevent from falling In installing or repair tools and components should be prevented from falling Regularly check the reliability of the installation frame TubingConnection Detach the valve cove...

Страница 27: ...e plate Close the connection lid screw it tightly and close the inlet grid 2 Outdoor unit Unscrew and dismantle the electronic device lid Fig 13 Dismantle the pressure plate of wire fastener Connect t...

Страница 28: ...wn Blue Yellow Green 5 Yellow Green Blue Brown Brown Blue Yellow Green 1 2 Brown 1 Blue N 2 N 3 Yellow Green 3 4 5 1 2 N 3 4 5 Brown 1 N 2 Blue Yellow Green 1 2 N 3 4 5 Brown 1 N 2 3 4 5 Blue Yellow G...

Страница 29: ...st be careful do not damage the pipeline and drain pipe Strapping should start from the lower part of the outdoor unit to the indoor unit Fix the PVC tape with adhesive tape to prevent loosing Drainpi...

Страница 30: ...e are leakage at all indoors and outdoors connections Put the valve bonnet and valve cover back to the position Narrow tube Wide tube Open Service valve Fig 16 2 Pumping type Make sure that all the tu...

Страница 31: ...alve Screw tightly the entire valve bonnet by torque spanner Check with soap water or leak detector whether there are leakage at all indoors and outdoors connections Put the valve bonnet and lid back...

Страница 32: ...ry bag Outdoor unit should be placed on blocks Chassis outdoor Elbow joint Fig 18 Drain pipe buy it by user Installation for the cover of valve Optional For the whole unit that individual cover of val...

Страница 33: ......

Отзывы: