8. Guarantee

This device is covered by a 

5 year guarantee

 from the date of 

purchase. The guarantee is valid only on presentation of the guarantee 

card completed by the dealer (see back) confirming date of purchase 

or the receipt.

Batteries, cuff and parts that become worn with use are not included.

Opening or altering the device invalidates the guarantee.

The guarantee does not cover damage caused by improper 

handling, discharged batteries, accidents or non-compliance with

the operating instructions.

Please contact your local Microlife-Service (see foreword).

9. Technical Specifications

Operating conditions:

10 - 40 °C / 50 - 104 °F

15 - 95 % relative maximum humidity

Storage conditions:

-20 - +55 °C / -4 - +131 °F

15 - 95 % relative maximum humidity

Weight:

112 g (including batteries)

Dimensions:

81 x 65 x 21 mm

Cuff size:

13.5 - 23 cm (5.25 - 9.05 inches)

Measuring procedure:

oscillometric, corresponding to Korotkoff 

method: Phase I systolic, Phase V diastolic

Measurement range:

20 - 280 mmHg – blood pressure

 

40 - 

199

 beats per minute – pulse

Cuff pressure display 

range:
Resolution:
Static accuracy:
Pulse accuracy:
Voltage source:
Battery lifetime:

IP Class:

Reference to 

standards:

0 - 299 mmHg
1 mmHg
pressure within ± 3 mmHg
± 5 % of the readout value
2 x 1.5 V alkaline batteries; size AAA

 

approx. 320 measurements 
(using new batteries)

IP20: Protected against solid foreign 

particles with a diameter of more than 

12.5 mm, no protection against water .

EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11

Expected service life:

 

Device: 5 years or 10000 measurements

  Cuff: 2 years or 10000 measurements

This device complies with the requirements of the Medical Device 

Directive 93/42/EEC.

Technical alterations reserved.

Содержание W3 Comfort

Страница 1: ...olife com Asia Microlife Corporation 9F 431 RuiGuang Road NeiHu Taipei 11492 Taiwan R O C Tel 886 2 8797 1288 Fax 886 2 8797 1283 Email service microlife com tw www microlife com North Central South America Microlife USA Inc 1617 Gulf to Bay Blvd 2nd Floor SuiteA Clearwater FL33755 USA Tel 1 727 442 5353 Fax 1 727 442 5377 Email msa microlifeusa com www microlife com C C C ...

Страница 2: ...arihi Fecha de compra Data da compra Datum van aankoop Ημερομηνία αγοράς Specialist Dealer Revendeur Categoria riven ditore Fachhändler Uzman satıcı Distribuidor especializado Revendedor autorizado Specialist Dealer Εξειδικευμένος αντιπρόσωποςa اﻟﻜﻔﺎﻟﺔ ﺑﻄﺎﻗﺔ اﻟﺨﻠﻔﻲ اﻟﻐﻄﺎء اﻧﻈﺮ اﻟﻜﻔﺎﻟﺔ ﺑﻄﺎﻗﺔ اﻟﻤﺸﺘﺮي اﺳﻢ اﻟﻤﻮدﻳﻞ اﻟﺘﺴﻠﺴﻞ رﻗﻢ اﻟﺸﺮاء ﺗﺎرﻳﺦ اﻟﻤﺨﺘﺺ اﻟﺘﺎﺟﺮ اﻟﻜﻔﺎﻟﺔ ﺑﻄﺎﻗﺔ اﻟﺨﻠﻔﻲ اﻟﻐﻄﺎء اﻧﻈﺮ اﻟﻜﻔﺎﻟﺔ ﺑﻄﺎﻗﺔ اﻟ...

Страница 3: ...rs or older Dear Customer Thisdevicewasdevelopedincollaborationwithphysiciansandclinicaltests carried out prove its measurement accuracy to be of a very high standard If you have any questions problems or want to order spare parts please contact your local Microlife Customer Service Your dealer or pharmacy will be able to give you the address of the Microlife dealer in your country Alternatively v...

Страница 4: ...replacement Which batteries and which procedure Using rechargeable batteries 6 Error Messages 7 Safety Care Accuracy Test and Disposal Safety and protection Device care Cleaning the cuff Accuracy test Disposal 8 9 Guarantee Technical Specifications 1 Using the Device for the First Time Inserting the batteries After you have unpacked your device first insert the batteries The battery compartment 5 ...

Страница 5: ... height as your heart 3 Taking a Blood Pressure Measurement 1 Press the ON OFF button 1 to start the measurement 2 The cuff fit check AO on the display indicates that the cuff is perfectly placed If the icon AO A appears the cuff is fitted subop timally but it is still ok to measure 3 The cuff will now pump up automatically Relax do not move and do not tense your arm muscles until the measurement ...

Страница 6: ...tically stores the last 30 measurement values Viewing the stored values Press the M button 3 briefly when the device is switched off The display first shows M AK and A which stands for the average of all stored values Pressing the M button again displays the previous value Pressing the M button repeatedly enables you to move from one stored value to another Blood pressure readings with suboptimal ...

Страница 7: ...replacement batteries Flat battery replacement When the batteries are flat the battery symbol AQ will flash as soon as the device is switched on flat battery displayed You cannot take any further measurements and must replace the batteries 1 Open the battery compartment 5 by pulling off the cap 2 Replace the batteries ensure correct polarity as shown by the symbols in the compartment 3 To set date...

Страница 8: ...scription Potential cause and remedy ERR 1 AN Signal too weak The pulse signals on the cuff are too weak Re position the cuff and repeat the measurement ERR 2 AO Error signal During the measurement error signals were detected by the cuff caused for instance by movement or muscle tension Repeat the measurement keeping your arm still ERR 3 AO No pressure in the cuff An adequate pressure cannot be ge...

Страница 9: ...d Read the additional safety information provided within the indi vidual sections of this instruction manual The measurement results given by this device is not a diagnosis It is not replacing the need for the consultation of a physician especially if not matching the patient s symptoms Do not rely on the measurement result only always consider other potentially occurring symptoms and the patient ...

Страница 10: ...12 g including batteries Dimensions 81 x 65 x 21 mm Cuff size 13 5 23 cm 5 25 9 05 inches Measuring procedure oscillometric corresponding to Korotkoff method Phase I systolic Phase V diastolic Measurement range 20 280 mmHg blood pressure 40 199 beats per minute pulse Cuff pressure display range Resolution Static accuracy Pulse accuracy Voltage source Battery lifetime IP Class Reference to standard...

Отзывы: