background image

2

Table of Contents

1. Important Facts about Blood Pressure and Self-Measurement

• How do I evaluate my blood pressure?

2. Important Facts about Atrial Fibrillation (AFIB)

• What is Atrial Fibrillation (AFIB)?
• How does AFIB impact my family or me?
• Microlife AFIB detection provides a convenient way to 

screen for AFIB (only in MAM mode)

• Risk factors you can control

3. Using the Device for the First Time

• Activating the fitted batteries
• Setting the date and time
• Selecting the correct cuff
• Select the measuring mode: standard or MAM mode
• MAM  mode

4. Taking a Blood Pressure Measurement using this Device

• How not to store a reading

5. Appearance of the Atrial Fibrillation Indicator for early 

Detection (only in MAM mode)

6. PC-Link Functions

• Installation and data transmission

7. Data Memory

• Viewing the stored values
• Memory full
• Clearing all values

8. Battery Indicator and Battery change

• Low battery
• Flat battery – replacement
• Which batteries and which procedure?
• Using rechargeable batteries

9. Using a Mains Adapter

10. Error Messages
11. Safety, Care, Accuracy Test and Disposal

• Safety and protection
• Device care
• Cleaning the cuff
• Accuracy test
• Disposal

12. Guarantee
13. Technical Specifications

Guarantee Card

1. Important Facts about Blood Pressure and Self-

Measurement

Blood pressure

 is the pressure of the blood flowing in the 

arteries generated by the pumping of the heart. Two values, the 

systolic

 (upper) value and the 

diastolic

 (lower) value, are 

always measured.

The device indicates the 

pulse rate

 (the number of times the 

heart beats in a minute).

Permanently high blood pressure values can damage your 

health and must be treated by your doctor!

 

Always discuss your values with your doctor and tell him/her if 

you have noticed anything unusual or feel unsure. 

Never rely 

on single blood pressure readings. 

Enter your readings in the enclosed 

blood pressure diary

This will give your doctor a quick overview.

There are many causes of excessively 

high blood pressure 

values

. Your doctor will explain them in more detail and offer 

treatment where appropriate. Besides medication, relaxation 

techniques, weight loss and exercise can also lower your blood 

pressure.

Under no circumstances should you alter the dosages of 

any drugs prescribed by your doctor!

Depending on physical exertion and condition, blood pressure is 

subject to wide fluctuations as the day progresses. 

You should 

therefore take your measurements in the same quiet condi-

tions and when you feel relaxed!

 Take at least two measure-

ments per day, one in the morning and one in the evening.

It is quite normal for two measurements taken in quick succes-

sion to produce significantly 

different results

.

Deviations

 between measurements taken by your doctor or in 

the pharmacy and those taken at home are quite normal, as 

these situations are completely different.

Several measurements

 provide a much clearer picture than 

just one single measurement.

Leave a small break

 of at least 15 seconds between two 

measurements.

If you are 

pregnant

, you should monitor your blood pressure 

very closely as it can change drastically during this time! 

If you suffer from an 

irregular heartbeat

, measurements taken 

with this device should only be evaluated after consultation with 

your doctor.

The pulse display is not suitable for checking the 

frequency of heart pacemakers!

Содержание BP A110

Страница 1: ...ww microlife com Asia Microlife Corporation 9F 431 RuiGang Road NeiHu Taipei 11492 Taiwan R O C Tel 886 2 8797 1288 Fax 886 2 8797 1283 Email service microlife com tw www microlife com North Central S...

Страница 2: ...5 BP A110 UA o Microlife 12 5 o Microlife 13 93 42 EEC 10 40 C 15 95 20 55 C 15 95 560 152 x 92 x 42 I V 20 280 40 200 0 299 1 3 5 4 x 1 5 AA 6 600 920 AA 4 IP IP20 EN 1060 1 3 4 IEC 60601 1 IEC 60601...

Страница 3: ...etects patients with AFIB at 97 100 certainty 1 2 Please read through these instructions carefully so that you under stand all functions and safety information We want you to be happy with your Microl...

Страница 4: ...h blood pressure values can damage your health and must be treated by your doctor Always discuss your values with your doctor and tell him her if you have noticed anything unusual or feel unsure Never...

Страница 5: ...tery compartment AT Setting the date and time 1 After the new batteries are fitted the year number flashes in the display You can set the year by pressing the M button 2 To confirm and then set the mo...

Страница 6: ...7 The cuff will now pump up automatically Relax do not move and do not tense your arm muscles until the measurement result is displayed Breathe normally and do not talk 8 When the correct pressure is...

Страница 7: ...y capacity of 200 is not exceeded When the memory is full the old values are automatically overwritten with new ones Values should be evaluated by a doctor before the memory capacity is reached otherw...

Страница 8: ...fety and protection This device may only be used for the purposes described in these instructions The manufacturer cannot be held liable for damage caused by incorrect application This device comprise...

Страница 9: ...ase The guarantee is valid only on presentation of the guar antee card completed by the dealer see back confirming date of purchase or the receipt Batteries cuff and parts that become worn with use ar...

Страница 10: ...riakidis M Diagnostic accuracy of a home blood pressure monitor to detect atrial fibrillation J Hum Hyperten 2009 1 5 2 Wiesel J Fitzig L Herschman Y Messineo FC Detection of Atrial Fibrillation Using...

Страница 11: ...9 BP A110 RU 1 2 AFIB AFIB AFIB Microlife MAM 3 MAM MAM 4 5 AFIB MAM 6 7 8 9 10 11 12 13 1 o a e...

Страница 12: ...150 85 120 98 c 2 AFIB AFIB 65 40 AFIB Microlife MAM AFIB Microlife 3 AT 1 M 2 Time 5 2 M Time 3 WHO 2003 100 60 1 100 120 60 80 2 120 130 80 85 3 130 140 85 90 4 140 160 90 100 5 160 180 100 110 6 18...

Страница 13: ...e Easy Microlife Microlife 6 7 4 MAM MAM MAM AK 1 MAM 3 MAM MAM AFIB MAM 1 MAM BK 1 2 3 15 15 Blood Pressure Monitoring 2001 6 145 147 4 1 2 3 4 5 2 3 6 1 7 8 9 BT S 17 22 6 75 8 75 M 22 32 8 75 12 5...

Страница 14: ...12 10 AM AN AO 11 12 1 y 1 M AS M 2 30 40 5 AFIB MAM AP AFIB AFIB 6 Microlife Blood Pressure Analyser BPA CD BPA www microlife ru USB B 5 1 CD ROM SETUP EXE 2 3 3 3...

Страница 15: ...13 BP A110 RU help 7 M 2 M AS M 17 17 M M 200 M CL M CL 8 AR AR 1 AT 2 3 3 4 1 5 AA oc a NiMH 9 Microlife 6 600 Microlife Microlife 230 1 8 2...

Страница 16: ...14 10 ERR 3 1 11 1 ERR 1 ERR 2 ERR 3 ERR 5 ERR 6 MAM MAM HI 300 200 5 LO 40...

Страница 17: ...Microlife 13 93 42 EEC 2015 2623 02 06 2015 2 2 5 c 10 10 40 C 15 95 20 55 C 15 95 560 152 x 92 x 42 I V 20 280 40 200 0 299 1 3 5 4 x 1 5 AA 6 600 920 AA 4 IP20 EN 1060 1 3 4 IEC 60601 1 IEC 60601 1...

Страница 18: ...16 27 495 325 45 63 8 800 200 33 22...

Страница 19: ...17 BP A110 RU...

Страница 20: ...iakidis M Diagnostic accuracy of a home blood pressure monitor to detect atrial fibrillation J Hum Hyperten 2009 1 5 2 Wiesel J Fitzig L Herschman Y Messineo FC Detection of Atrial Fibrillation Using...

Страница 21: ...19 BP A110 UA 1 2 AFIB AFIB i Microlife AFIB i MAM 3 MAM MAM 4 5 i MAM 6 7 8 9 10 11 12 13 1 a 15...

Страница 22: ...B AFIB atria i 65 40 Microlife AFIB i MAM i Microlife AFIB i i i 3 AT 1 M 2 Time 5 2 M Time 3 4 Time 5 Time 3 Microlife 2003 100 60 1 100 120 60 80 2 120 130 80 85 3 130 140 85 90 4 140 160 90 100 5 1...

Страница 23: ...ife 6 7 4 MAM MAM MAM AK 1 MAM 3 MAM MAM i MAM 1 MAM BK 1 2 3 15 15 Blood Pressure Monitoring 2001 6 145 147 4 1 2 3 4 5 2 3 6 1 7 8 9 BT 10 AM AN AO 11 12 1 S 17 22 6 75 8 75 M 22 32 8 75 12 5 L 32 4...

Страница 24: ...22 y 1 M AS M 2 30 40 5 i MAM AP i 6 Microlife Blood Pressure Monitor BPA Microlife BPA D www microlife com ua USB B 5 1 CD D ROM SETUP EXE 2 H 3 3 i i help 7 M 2 M AS M 17 17 i...

Страница 25: ...23 BP A110 UA M M a 200 i y i M CL M CL 8 AR AR 1 AT 2 3 3 4 1 5 AA NiMH i i i e 9 Microlife DC 6 600 Microlife Microlife 230 1 8 2 10 ERR 3 ERR 1...

Страница 26: ...24 1 11 1 2 ERR 2 ERR 3 ERR 5 ERR 6 MAM MAM HI 300 200 5 LO 40...

Страница 27: ...icrolife 12 5 o Microlife 13 93 42 EEC 10 40 C 15 95 20 55 C 15 95 560 152 x 92 x 42 I V 20 280 40 200 0 299 1 3 5 4 x 1 5 AA 6 600 920 AA 4 IP IP20 EN 1060 1 3 4 IEC 60601 1 IEC 60601 1 2 EMC IEC 606...

Отзывы: