MHX 910A Operating Manual: Chapter3 Installation
9
3.2
Internal Cabling
This section describes the recommended procedure for installing cabling and
antennas for use with the MHX-910A module.
The most common method for installing the module is to run a cable from
the module’s MCX connector to a reverse TNC bulkhead connector on the
chassis of the equipment as shown in Figure 3. This cable can be purchased
from Microhard Systems.
Figure 3 Suggested Internal Cabling
Cable losses are negligible for the short piece used within the chassis.
Additional losses up to 0.5 dB may be present in the MCX and Reverse TNC
connections.
RG316 Cable with MCX
male connector and
Reverse TNC bulkhead
connector
Reverse TNC connector
MCX female connector
MHX-910A