micro
HAM ©
2016
All rights reserved
CONTROL PORT
The Control Port allows an application program (logger) that implements the microHAM Control Protocol to make
use of Station Master's antenna switching control.
When an application opens the control port, Router
reports port as
open
and displays settings used to configure the port.
Data flow is indicated by two arrows. The green arrow indicates data flow from the application and a red arrow
indicates data to the host application.
Mon:
Opens a “Control Protocol Monitor” window to capture microHAM Protocol communications between a
logger and Router. Controls for the monitor include
Start, Stop, Clear
and
Save
.
The Control Protocol Monitor functions the same as the Rotor Port Monitors.
iLINK couple
When Station Master Deluxe
is used with
micro
KEYER II, MK2R or MK2R+ and the two devices are connected
using the iLINK port, the
iLINK couple
box specifies the keyer to which Station Master Deluxe
coupled. When
SMD is coupled to a keyer, all important data such as frequency, mode, keying, locks and native control data
(Control Port) are transferred between Station Master Deluxe
and the keyer to synchronize operations.
IMPORTANT: Don't forget to set SMD to the CAT mode by entering menu [m1] and selecting *** CAT *** !
IMPORTANT:
When SMD is coupled, click Device | Store as default settings on both SMD and the keyer!
Otherwise coupling will not work in stand alone mode.
NOTE:
If Station Master Deluxe is not physically connected to the iLINK port of a
micro
HAM keyer or coupling is
unwanted even when the devices are physically connected, select
none
in the coupling box.
IMPORTANT: If coupling is enabled, the keyer expects an SMD on the iLink port even if SMD is not
connected to Router (or USB bus). When devices have to be decoupled, coupling MUST be set to
none, even if the SMD tab has a red cross!
The CAT and 2
nd
CAT ports operate differently depending on the type of
micro
HAM interface being used.
Read carefully!
●
When SMD is used with
micro
KEYER, DigiKeyer, DigiKeyer II, or CW Keyer, the transceiver radio
control port must be connected to the
Station Master Deluxe
– the CAT connection on the
KEYER
is
not used. The CAT and 2
nd
CAT port settings on Ports tab for the
KEYER
are ignored.
Use the Control port on the
KEYER's
Ports tab for native control from applications that support the
micro
HAM Control protocol.
●
When SMD is coupled with
micro
KEYER II, MK2R or MK2R+, the transceiver CAT port must be
connected to the
KEYER
and the SMD CAT port is not used. The CAT and 2
nd
CAT port settings on
Ports tab for
Station Master Deluxe
are ignored.
Use the Control port on the
KEYER's
Ports tab for native control of both devices from applications that
support the
micro
HAM Control protocol.