background image

5 of 5 

PRX4SERL Four-Zone Receiver Decoder 

 

Fit the required switch cables to the appropriate relays. These are labeled Zone 1 to Zone 4. Terminals are 

available on each relay for Normally Open, Normally closed and Common. 
 

Finally, connect the blue latching power connector to a 12V dc @ 0.5A power supply, observing the correct 

polarity, as shown in diagram 1. 
 

Where the unit has been ordered as a PRX4SERL with the serial port enabled, the 9 way D connector is 

used to connect the unit to a serial printer or PC for data logging purposes, or to a Scope transmitter for a 
repeater application. The serial port configuration is 9600 baud, N, 8, 1. A standard serial cable (null 

modem) is required. 
 

 

Operation 
 
PRX4SERL 

 

This unit utilizes firmware which facilitates the following features: 

 

1) There are four configurable capcode ranges which can be specified for activating each relay. Each range 
can be specified as either numeric or alphanumeric. Sending a capcode within the set range will latch the 

relevant relay and light the corresponding onboard LED. 

 
2) An on-board sounder can be configured to beep every time data is received. 

 

3) Serial output is available on the 9 way D-Connector. This can be specified to output text only (for 
connection to a printer or PC), or Scope protocol for onward connection to another Scope transmitter (for 

use as a repeater). 
 

4) The receiver will decode POCSAG transmissions sent at 512 baud or 1200 baud (not both). This must 

match the transmitter over the air baud rate. 
 

All these features are factory set, so they need to be specified at the time of order placement. 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 

 

 

Содержание PRX4SERL

Страница 1: ...our Zone Receiver Decoder Operating Manual Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Страница 2: ...ication to the product without first contacting Microframe Corporation Warning All power transformers line cords and electrical equipment should be kept out of the reach of children and away from water If you are installing cable in an air plenum area such as a drop ceiling used for air return you must use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for insta...

Страница 3: ...n to the aerial selected and where the unit is mounted in relation to the transmitter being monitored If the unit is to be used with a second transmitter it should be sited as centrally as possible within the secondary area to be covered although it must of course be within adequate distance of the originating transmitter The unit should be at least two meters away from any transmitter It is there...

Страница 4: ...al cable between the antenna and the receiver If cable runs exceed 5 meters always use low loss 50 ohm cable such as RG213 or UR67 to a maximum of 15 meters Coaxial cable intended for TV Satellite or CCTV installations is normally 75 OHM and therefore totally unsuitable for any receiver installation manufactured by Scope 5 Also remember that the performance of the system will be affected by the ty...

Страница 5: ...ation PRX4SERL This unit utilizes firmware which facilitates the following features 1 There are four configurable capcode ranges which can be specified for activating each relay Each range can be specified as either numeric or alphanumeric Sending a capcode within the set range will latch the relevant relay and light the corresponding onboard LED 2 An on board sounder can be configured to beep eve...

Страница 6: ... reset the unit and de energize all the relays Note where the serial port has been set to output Scope protocol it must be connected to a valid serial port for this feature to operate The unit can also be reset by depressing SW1 through the hole provided on the lower endplate see Diagram 1 below ...

Страница 7: ...SAG FSK NRZ Normal or Inverted Frequency fixed crystal In the range 440 470MHz Frequency Stability 10ppm Channel Spacing 12 5 or 25KHz Frequency Deviation 4 5KHz Over Air Baud Rate fixed programmable 512 or 1200 bps Sensitivity Maximum 512bps 6μV m 1200bps 7 5μV m Selectivity 52dB Image Rejection 52dB Spurious Rejection 60dB Intermodulation 52dB Relay Contact max rating 0 5A 125V ac 1A 60V dc Seri...

Страница 8: ...8 of 8 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Отзывы: