The pilot plant solely contains the membrane filtration part for separating cleaned waste water
from activated sludge
– the main pre-treatment steps (mechanical pre-treatment) is not part of
the pilot plant. You may use the integrated 1 mm inlet screen as a final step of the pre-treatment
or directly guide the pre-treated waste water to the filtration tank. Instructions for the construction
of the pre-treatment can be found in the MICRODYN BIO-CEL
®
Design Guidelines.
Figure 3.
drawing (left) and photo (right) of the pilot plant
Equipment
The equipment installed in the pilot plant is listed below. The specifications are equal to the
specifications in the P&ID (Figure 5. P&ID of the pilot plant).
Table 3
: Overview of equipment
Specification Abbreviation Description
Remark
Membrane
module
1 x BIO-CEL XS-1
10m²
membrane
surface
Tanks
B1
Inlet tank screen
1mm bar screen
B2
Screenings tank
Not on P&ID
B3
Filtration tank
900 L
B4
Permeate tank
35 L
Pumps
P1
Feed pump
(not included in
delivery)
P2
Permeate pump
80
– 250 L/h
Blower
G1
Blower for cross flow aeration
Sensors
PICR
Pressure sensor permeate
FICR
Flow meter permeate
LS
Level permeate tank
LSIC
Filling level membrane tank
Schaltschrank
Gebläse
Siebgutkasten
Zulauf-Bogensieb
Permeatbehälter
Permeatpumpe
Inlet Screen
Control panel
Blower
Screenings
tank
Permeate
tank
Permeate
pump