Important:
Make sure that prior to setting the port to a link local addressing mode that you have a PC Ethernet
port that can be set to a static link local IP address in subnet with the Admin Ethernet Port's
address. As soon as the addressing mode has been saved as link local, the Admin Ethernet port
will receive a new a link local address.
If you are accessing the CMT via the Admin Ethernet port, any time the IP address of the port
changes you will have to log back into the CMT using the new address as your URL. If the new
address is out of subnet with your PC's port, you will be unable to access the CMT via the GridTime
3000's Admin Ethernet port until you change your PC's IP address to be in subnet.
If this happens by mistake, you can also use the Admin USB-C port to log back into the CMT and
change the IP address of the Admin Ethernet port to an in subnet address.
2.
Network Name
If required, the network name can be modified if by typing the new name into the 'NETWORK NAME' textbox.
This field will set the hostname of the port.
By default, the network name will be 'gt3k-admin'.
3.
Save Settings
Click the 'SAVE' button to write the settings to the GridTime 3000.
A 'Saved!' notification will appear in the bottom right corner of the page, indicating that the settings have
successfully been written to the GridTime 3000.
9.5
Provisioning the Ethernet Ports
This section describes how to provision the Ethernet ports on the GridTime 3000.
The Ethernet ports on the GridTime 3000 can be configured as Network Time Protocol (NTP) clients and servers, and
Precision Time Protocol (PTP) clients and servers. PTP can also be run over two ports simultaneously as a Parallel
Redundancy Protocol (PRP) pair.
Prior to configuring the NTP or PTP settings, basic port network settings should be set up according to the steps
below.
1.
Navigate to Ethernet Port Configuration Window
The port tab should be brought up by clicking on the Ethernet Timing Ports icon, then clicking the settings bar
corresponding to the port.