SPLICE
SWITCH SUPPLIED BY USER
(SWITCH CLOSED = RUN)
OPTIONAL RUN/HOLD CONNECTION
CUT JUMPER AND WIRE TO
SWITCH AS SHOWN
MOTOR
BLUE –
RUN/HOLD
DUST COVER W/JUMPER
P/N 13100
3-PIN M/P 150 SHROUD
BATTERY
WHITE
(+12 VDC)
TO FUSE TO
POSITIVE BATTERY
BLACK
(GROUND)
ORANGE
(+12 VDC)
BLACK
(GROUND)
TO NEGATIVE
BATTERY
POWER CABLE
P/N 17444
10 FT.
MOTOR CABLE
P/N 17448
20 FT.
BLACK - TO NEGATIVE
PUMP LEAD
WHITE - TO POSITIVE
PUMP LEAD
25A Manual Controller
Installation Instructions
© 2019 Micro-Trak Systems, Inc.
•
P/N 50236
•
113021
OPTIONAL 2-PIN M/P 280 MOTOR
EXTENSION CABLES
P/N 17445
10'
CABLE
P/N 17446
20'
CABLE
IMPORTANT!
Do
not
connect the motor
leads to the battery or power
supply. Resulting damage to
controller will
not
be covered
under warranty.
Optional Pressure Gauge Bracket
also available - P/N 14799
LED STATUS INDICATOR CODES
Light on steady
Unit is turned on and operating normally
Steady Flashing
Unit in HOLD. Check Run/Hold jumper or remote
switch for correct operation.
1 Flash/pause
Open circuit detected. Check motor connections for
open circuit.
2 Flashes/pause
Output short circuit detected. Check motor wir-
ing.
3 Flashes/pause
Over-current condition. Check total load.
NOTE: Cycle power with the ON/OFF switch to clear a fault code
Front View