Options for
Temperature Measurement Unit
Table 4-2:
Unit description
Label
Display
ProLink III
Field Communica-
tor
Degrees Celsius
°C
°C
degC
Degrees Fahrenheit
°F
°F
degF
Degrees Rankine
°R
°R
degR
Kelvin
°K
°K
Kelvin
4.3.2
Configure
Temperature Damping
Display
Not available
ProLink III
Device Tools
>
Configuration
>
Process Measurement
>
Line Temperature
>
Temperature Damping
Field Communicator
Configure
>
Manual Setup
>
Measurements
>
Temperature
>
Temperature Damping
Overview
Temperature Damping
controls the amount of damping that will be applied to the line
temperature value, when the on-board temperature data is used (RTD).
Damping is used to smooth out small, rapid fluctuations in process measurement.
Damping
Value
specifies the time period (in seconds) over which the transmitter will spread changes
in the process variable. At the end of the interval, the internal value will reflect 63% of the
change in the actual measured value.
Tip
Temperature Damping
affects all process variables, compensations, and corrections that use
temperature data from the sensor.
Procedure
Enter the value you want to use for
Temperature Damping
.
The default value is 4.8 seconds.
Tips
•
A high damping value makes the process variable appear smoother because the reported value
changes slowly.
•
A low damping value makes the process variable appear more erratic because the reported value
changes more quickly.
•
Whenever the damping value is non-zero, the reported measurement will lag the actual
measurement because the reported value is being averaged over time.
Configure process measurement
Configuration and Use Manual
29
Содержание CDM100M
Страница 8: ...Getting Started 2 Micro Motion Compact Density Meters CDM ...
Страница 12: ...Before you begin 6 Micro Motion Compact Density Meters CDM ...
Страница 20: ...Configuration and commissioning 14 Micro Motion Compact Density Meters CDM ...
Страница 26: ...Introduction to configuration and commissioning 20 Micro Motion Compact Density Meters CDM ...
Страница 110: ...Integrate the meter with the control system 104 Micro Motion Compact Density Meters CDM ...
Страница 116: ...Operations maintenance and troubleshooting 110 Micro Motion Compact Density Meters CDM ...
Страница 124: ...Transmitter operation 118 Micro Motion Compact Density Meters CDM ...
Страница 194: ...Using the transmitter display 188 Micro Motion Compact Density Meters CDM ...
Страница 208: ...Using ProLink III with the transmitter 202 Micro Motion Compact Density Meters CDM ...
Страница 218: ...Concentration measurement matrices derived variables and process variables 212 Micro Motion Compact Density Meters CDM ...
Страница 219: ...Concentration measurement matrices derived variables and process variables Configuration and Use Manual 213 ...